1,059 research outputs found
Diagnostic Ultrasound Induced Inertial Cavitation To Non-Invasively Restore Coronary And Microvascular Flow In Acute Myocardial Infarction
Ultrasound induced cavitation has been explored as a method of dissolving intravascular and microvascular thrombi in acute myocardial infarction. The purpose of this study was to determine the type of cavitation required for success, and whether longer pulse duration therapeutic impulses (sustaining the duration of cavitation) could restore both microvascular and epicardial flow with this technique. Accordingly, in 36 hyperlipidemic atherosclerotic pigs, thrombotic occlusions were induced in the mid-left anterior descending artery. Pigs were then randomized to either a) 1/2 dose tissue plasminogen activator (0.5 mg/kg) alone; or same dose plasminogen activator and an intravenous microbubble infusion with either b) guided high mechanical index short pulse (2.0 MI; 5 usec) therapeutic ultrasound impulses; or c) guided 1.0 mechanical index long pulse (20 usec) impulses. Passive cavitation detectors indicated the high mechanical index impulses (both long and short pulse duration) induced inertial cavitation within the microvasculature. Epicardial recanalization rates following randomized treatments were highest in pigs treated with the long pulse duration therapeutic impulses (83% versus 59% for short pulse, and 49% for tissue plasminogen activator alone; p \u3c 0.05). Even without epicardial recanalization, however, early microvascular recovery occurred with both short and long pulse therapeutic impulses (p \u3c 0.005 compared to tissue plasminogen activator alone), and wall thickening improved within the risk area only in pigs treated with ultrasound and microbubbles. We conclude that although short pulse duration guided therapeutic impulses from a diagnostic transducer transiently improve microvascular flow, long pulse duration therapeutic impulses produce sustained epicardial and microvascular re-flow in acute myocardial infarction
General Purpose Real-Time Object Tracking using Hausdorff Transforms
We describe a real-time computer-vision tracking module capable of using several Hausdorff distance based approaches to localize and match edge models in a scene. The implementation is based on widely supported software and hardware technologies such as Microsoft DirectX/DirectShow, Intel Image Processing and the Open Source Computer Vision libraries
Decay of scalar variance in isotropic turbulence in a bounded domain
The decay of scalar variance in isotropic turbulence in a bounded domain is
investigated. Extending the study of Touil, Bertoglio and Shao (2002; Journal
of Turbulence, 03, 49) to the case of a passive scalar, the effect of the
finite size of the domain on the lengthscales of turbulent eddies and scalar
structures is studied by truncating the infrared range of the wavenumber
spectra. Analytical arguments based on a simple model for the spectral
distributions show that the decay exponent for the variance of scalar
fluctuations is proportional to the ratio of the Kolmogorov constant to the
Corrsin-Obukhov constant. This result is verified by closure calculations in
which the Corrsin-Obukhov constant is artificially varied. Large-eddy
simulations provide support to the results and give an estimation of the value
of the decay exponent and of the scalar to velocity time scale ratio
Microbubble Cavitation Imaging
Ultrasound cavitation of microbubble contrast agents has a potential for therapeutic applications such as sonothrombolysis (STL) in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (moderate oscillations, stable cavitation, and inertial cavitation) and activity level in and around a treatment area. Acoustic passive cavitation detectors (PCDs) have been used to this end but do not provide spatial information. This paper presents a prototype of a 2-D cavitation imager capable of producing images of the dominant cavitation state and activity level in a region of interest. Similar to PCDs, the cavitation imaging described here is based on the spectral analysis of the acoustic signal radiated by the cavitating microbubbles: ultraharmonics of the excitation frequency indicate stable cavitation, whereas elevated noise bands indicate inertial cavitation; the absence of both indicates moderate oscillations. The prototype system is a modified commercially available ultrasound scanner with a sector imaging probe. The lateral resolution of the system is 1.5 mm at a focal depth of 3 cm, and the axial resolution is 3 cm for a therapy pulse length of 20 mu s. The maximum frame rate of the prototype is 2 Hz. The system has been used for assessing and mapping the relative importance of the different cavitation states of a microbubble contrast agent. In vitro (tissue-mimicking flow phantom) and in vivo (heart, liver, and brain of two swine) results for cavitation states and their changes as a function of acoustic amplitude are presented
Effects Of Attenuation And Thrombus Age On The Success Of Ultrasound And Microbubble-Mediated Thrombus Dissolution
The purpose of this study was to examine the effects of applied mechanical index, incident angle, attenuation and thrombus age on the ability of 2-D vs. 3-D diagnostic ultrasound and microbubbles to dissolve thrombi. A total of 180 occlusive porcine arterial thrombi of varying age (3 or 6 h) were examined in a flow system. A tissue-mimicking phantom of varying thickness (5 to 10 cm) was placed over the thrombosed vessel and the 2-D or 3-D diagnostic transducer aligned with the thrombosed vessel using a positioning system. Diluted lipid-encapsulated microbubbles were infused during ultrasound application. Percent thrombus dissolution (%TD) was calculated by comparison of clot mass before and after treatment. Both 2-D and 3-D-guided ultrasound increased %TD compared with microbubbles alone, but %TD achieved with 6-h-old thrombi was significantly less than 3-h-old thrombi. Thrombus dissolution was achieved at 10 cm tissue-mimicking depths, even without inertial cavitation. In conclusion, diagnostic 2-D or 3-D ultrasound can dissolve thrombi with intravenous nontargeted microbubbles, even at tissue attenuation distances of up to 10 cm. This treatment modality is less effective, however, for older aged thrombi. (E-mail: [email protected]) (C) 2011 World Federation for Ultrasound in Medicine & Biology
Oxidation of cellulose in pressurized carbon dioxide
This work presents first results upon oxidation of type II cellulose by nitrogen dioxide dissolved in carbon dioxide at high pressure. This reaction leads to oxidized cellulose, a natural-based bioresorbable fabric used for biomedical applications. The oxidation reaction takes place in a heterogeneous fluid–solid system. Kinetics of oxidation is presented here and effects of operating conditions such as pressure, temperature and initial moisture content of cellulose are investigated. Results are presented in terms of degree of oxidation of cellulose and quality of the final oxidized cellulose, which has been characterized using liquid-state and solid-state 13C NMR. The experimental results show the existence of possible secondary reactions which may lead to oxidized cellulose with insufficient mechanical strength. An attempt is made to evidence and understand the role of CO2 as a solvent in this system. Indeed, although supercritical CO2 appears to be a suitable candidate as a solvent for oxidation reactions, some inhibiting effect on nitrogen dioxide activity are observed in this case
Diagnostic Ultrasound High Mechanical Index Impulses Restore Microvascular Flow In Peripheral Arterial Thromboembolism
We sought to explore mechanistically how intermittent high-mechanical-index (MI) diagnostic ultrasound impulses restore microvascular flow. Thrombotic microvascular obstruction was created in the rat hindlimb muscle of 36 rats. A diagnostic transducer confirmed occlusion with low-MI imaging during an intravenous microbubble infusion. This same transducer was used to intermittently apply ultrasound with an MI that produced stable or inertial cavitation (IC) for 10 min through a tissue-mimicking phantom. A nitric oxide inhibitor, L-Nω-nitroarginine methyl ester (L-NAME), was pre-administered to six rats. Plateau microvascular contrast intensity quantified skeletal microvascular blood volume, and postmortem staining was used to detect perivascular hemorrhage. Intermittent IC impulses produced the greatest recovery of microvascular blood volume (p \u3c 0.0001, analysis of variance). Nitric oxide inhibition did not affect the skeletal microvascular blood volume improvement, but did result in more perivascular hemorrhage. IC inducing pulses from a diagnostic transducer can reverse microvascular obstruction after acute arterial thromboembolism. Nitric oxide may prevent unwanted bio-effects of these IC pulses
SEARCH FOR NEUTRINO OSCILLATION AT BUGEY
The high flux of low energy [MATH]e produced by the core of a PWR reactor of Bugey power plant has been used to search for evidence of neutrino oscillations through the inverse beta decay reaction [MATH]e + p → e+ + n. Measurements have been performed at two distances (13.5 and 18.5m). About 50 000 [MATH]e events have been collected at the first position and 25 000 [MATH]e events at the second one. Data analysis is almost completed
Is the Shroud of Turin in Relation to the Old Jerusalem Historical Earthquake?
Phillips and Hedges suggested, in the scientific magazine Nature (1989), that
neutron radiation could be liable of a wrong radiocarbon dating, while proton
radiation could be responsible of the Shroud body image formation. On the other
hand, no plausible physical reason has been proposed so far to explain the
radiation source origin, and its effects on the linen fibres. However, some
recent studies, carried out by the first author and his Team at the Laboratory
of Fracture Mechanics of the Politecnico di Torino, found that it is possible
to generate neutron emissions from very brittle rock specimens in compression
through piezonuclear fission reactions. Analogously, neutron flux increments,
in correspondence to seismic activity, should be a result of the same
reactions. A group of Russian scientists measured a neutron flux exceeding the
background level by three orders of magnitude in correspondence to rather
appreciable earthquakes (4th degree in Richter Scale). The authors consider the
possibility that neutron emissions by earthquakes could have induced the image
formation on Shroud linen fibres, trough thermal neutron capture by Nitrogen
nuclei, and provided a wrong radiocarbon dating due to an increment in
C(14,6)content. Let us consider that, although the calculated integral flux of
10^13 neutrons per square centimetre is 10 times greater than the cancer
therapy dose, nevertheless it is100 times smaller than the lethal dose.Comment: 13 pages, 1 figur
- …
