20,893 research outputs found
Development of a polysilicon process based on chemical vapor deposition, phase 1
The development of a dichlorosilane-based reductive chemical vapor deposition process for the production of polycrystalline silicon is discussed. Experimental data indicate that the ease of ignition and explosion severity of dichlorosilane (DCS)/air mixtures is substantially attenuated if the DCS is diluted with hydrogen. Redesign of the process development unit to accommodate safety related information is described. Several different sources of trichlorosilane were used to generate a mixture of redistributed chlorosilanes via Dowex ion exchange resin. The unseparated mixtures were then fed to an experimental reactor in which silicon was deposited and the deposited silicon analyzed for electrically active impurities. At least one trichlorosilane source provided material of requisite purity. Silicon grown in the experimental reactor was converted to single crystal material and solar cells fabricated and tested
Recommended from our members
Metrics for pitch collections
Models of the perceived distance between pairs of pitch collections are a core component of broader models of the perception of tonality as a whole. Numerous different distance measures have been proposed, including voice-leading, psychoacoustic, and pitch and interval class distances; but, so far, there has been no attempt to bind these different measures into a single mathematical framework, nor to incorporate the uncertain or probabilistic nature of pitch perception (whereby tones with similar frequencies may, or may not, be heard as having the same pitch).
To achieve these aims, we embed pitch collections in novel multi-way expectation arrays, and show how metrics between such arrays can model the perceived dissimilarity of the pitch collections they embed. By modeling the uncertainties of human pitch perception, expectation arrays indicate the expected number of tones, ordered pairs of tones, ordered triples of tones and so forth, that are heard as having any given pitch, dyad of pitches, triad of pitches, and so forth. The pitches can be either absolute or relative (in which case the arrays are invariant with respect to transposition).
We provide a number of examples that show how the metrics accord well with musical intuition, and suggest some ways in which this work may be developed
Anthropology and Moral Philosophy: A Symposium on Michael Banner's The Ethics of Everyday Life
Improved synchronous production of Plasmodium falciparum gametocytes in vitro.
The sexual stages of the Plasmodium falciparum life cycle are attractive targets for vaccines and transmission blocking drugs. Difficulties in culturing and obtaining large amounts of sexual stage P. falciparum parasites, particularly early stages, have often limited research progress in this area. We present a new protocol which simplifies the process of stimulating gametocytogenesis leading to improved synchronous gametocyte production. This new method can be adapted to enrich for early stage gametocytes (I and II) with a higher degree of purity than has previously been achieved, using MACS magnetic affinity columns. The protocol described lends itself to large scale culturing and harvesting of synchronous parasites suitable for biochemical assays, northern blots, flow cytometry, microarrays and proteomic analysis
Genomic variations associated with attenuation in Mycobacterium avium subsp paratuberculosis vaccine strains
BACKGROUND: Mycobacterium avium subspecies paratuberculosis (MAP) whole cell vaccines have been widely used tools in the control of Johne's disease in animals despite being unable to provide complete protection. Current vaccine strains derive from stocks created many decades ago; however their genotypes, underlying mechanisms and relative degree of their attenuation are largely unknown.
RESULTS: Using mouse virulence studies we confirm that MAP vaccine strains 316 F, II and 2e have diverse but clearly attenuated survival and persistence characteristics compared with wild type strains. Using a pan genomic microarray we characterise the genomic variations in a panel of vaccine strains sourced from stocks spanning over 40 years of maintenance. We describe multiple genomic variations specific for individual vaccine stocks in both deletion (26-32 Kbp) and tandem duplicated (11-40 Kbp) large variable genomic islands and insertion sequence copy numbers. We show individual differences suitable for diagnostic differentiation between vaccine and wild type genotypes and provide evidence for functionality of some of the deleted MAP-specific genes and their possible relation to attenuation.
CONCLUSIONS: This study shows how culture environments have influenced MAP genome diversity resulting in large tandem genomic duplications, deletions and transposable element activity. In combination with classical selective systematic subculture this has led to fixation of specific MAP genomic alterations in some vaccine strain lineages which link the resulting attenuated phenotypes with deficiencies in high reactive oxygen species handling
Unsung heroes: who supports social work students on placement?
Since the introduction of the three year degree programme in 2003, social work education has undergone a number of significant changes. The time students spend on placement has been increased to two hundred days, and the range of placement opportunities and the way in which these placements have been configured has significantly diversified. A consistent feature over the years, however, has been the presence of a Practice Educator (PE) who has guided, assessed and taught the student whilst on placement. Unsurprisingly, the role of the PE and the pivotal relationship they have with the student has been explored in the past and features in social work literature.
This paper, however, concentrates on a range of other relationships which are of significance in providing support to students on placement. In particular it draws on research to discuss the role of the university contact tutor, the place of the wider team in which the student is sited, and the support offered by family, friends and others.
Placements and the work undertaken by PE’s will continue to be integral to the delivery of social work education. It is, however, essential to recognise and value the often over looked role of others in providing support to students on placement
Structural design of a vertical antenna boresight 18.3 by 18.3-m planar near-field antenna measurement system
A large very precise near-field planar scanner was proposed for NASA Lewis Research Center. This scanner would permit near-field measurements over a horizontal scan plane measuring 18.3 m by 18.3 m. Large aperture antennas mounted with antenna boresight vertical could be tested up to 60 GHz. When such a large near field scanner is used for pattern testing, the antenna or antenna system under test does not have to be moved. Hence, such antennas and antenna systems can be positioned and supported to simulate configuration in zero g. Thus, very large and heavy machinery that would be needed to accurately move the antennas are avoided. A preliminary investigation was undertaken to address the mechanical design of such a challenging near-field antenna scanner. The configuration, structural design and results of a parametric NASTRAN structural optimization analysis are contained. Further, the resulting design was dynamically analyzed in order to provide resonant frequency information to the scanner mechanical drive system designers. If other large near field scanners of comparable dimensions are to be constructed, the information can be used for design optimization of these also
Characteristics and capacities of the NASA Lewis Research Center high precision 6.7- by 6.7-m planar near-field scanner
A very precise 6.7- by 6.7-m planar near-field scanner has recently become operational at the NASA Lewis Research Center. The scanner acquires amplitude and phase data at discrete points over a vertical rectangular grid. During the design phase for this scanner, special emphasis was given to the dimensional stability of the structures and the ease of adjustment of the rails that determine the accuracy of the scan plane. A laser measurement system is used for rail alignment and probe positioning. This has resulted in very repeatable horizontal and vertical motion of the probe cart and hence precise positioning in the plane described by the probe tip. The resulting accuracy will support near-field measurements at 60 GHz without corrections. Subsystem design including laser, electronic and mechanical and their performance is described. Summary data are presented on the scan plane flatness and environmental temperature stability. Representative near-field data and calculated far-field test results are presented. Prospective scanner improvements to increase test capability are also discussed
Distinguishing between similar tubular objects using pulse reflectometry:a study of trumpet and cornet leadpipes
This paper considers the measurement of the internal radius of a number of similar, short, tubular leadpipes using pulse reflectometry. Pulse reflectometry is an acoustical technique for measuring the internal bore of a tubular object by analysing the reflections which occur when an acoustical pulse is directed into the object. The leadpipes are designed to form the initial, or lead, part of a trumpet or cornet and their internal radii differ by less than 0.1 mm between similar pipes. The ability of the reflectometer to detect these small differences, which are considered by players to produce a noticeable difference in the sound of an instrument, are investigated. It is seen that the pulse reflectometer is able to distinguish between leadpipes with different nominal radii varying by as little as 0.03 mm, demonstrating its potential in the study of musical instruments and showing that it can be used as a diagnostic tool by the instrument manufacturer to detect defects which are significant enough to acoustically alter performance. The absolute accuracy of the radius measurements is also considered at the end of the leadpipe, where the uncertainty is ±0.05 mm
- …
