3,611 research outputs found
An analysis of interplanetary solar radio emissions associated with a coronal mass ejection
Coronal mass ejections (CMEs) are large-scale eruptions of magnetized plasma
that may cause severe geomagnetic storms if Earth-directed. Here we report a
rare instance with comprehensive in situ and remote sensing observa- tions of a
CME combining white-light, radio, and plasma measurements from four different
vantage points. For the first time, we have successfully applied a radio
direction-finding technique to an interplanetary type II burst detected by two
identical widely separated radio receivers. The derived locations of the type
II and type III bursts are in general agreement with the white light CME recon-
struction. We find that the radio emission arises from the flanks of the CME,
and are most likely associated with the CME-driven shock. Our work demon-
strates the complementarity between radio triangulation and 3D reconstruction
techniques for space weather applications
Coulomb Corrections for Interferometry Analysis of Expanding Hadron Systems
The problem of the Coulomb corrections to the two-boson correlation functions for the systems formed in ultra-relativistic heavy ion collisions is considered for large effective system volumes. The modification of the standard zero-distance correction (so called Gamow or Coulomb factor) has been proposed for such a kind of systems. For the 1r+1r+ and [(+[(+ correlation functions the analytical calculations of the Coulomb correction are compared with the exact numerical results
The STAR Silicon Strip Detector (SSD)
The STAR Silicon Strip Detector (SSD) completes the three layers of the
Silicon Vertex Tracker (SVT) to make an inner tracking system located inside
the Time Projection Chamber (TPC). This additional fourth layer provides two
dimensional hit position and energy loss measurements for charged particles,
improving the extrapolation of TPC tracks through SVT hits. To match the high
multiplicity of central Au+Au collisions at RHIC the double sided silicon strip
technology was chosen which makes the SSD a half million channels detector.
Dedicated electronics have been designed for both readout and control. Also a
novel technique of bonding, the Tape Automated Bonding (TAB), was used to
fullfill the large number of bounds to be done. All aspects of the SSD are
shortly described here and test performances of produced detection modules as
well as simulated results on hit reconstruction are given.Comment: 11 pages, 8 figures, 1 tabl
A New Statistical Image Analysis Approach and Its Application to Hippocampal Morphometry
In this work, we propose a novel and powerful image analysis framework for hippocampal morphometry in early mild cognitive impairment (EMCI), an early prodromal stage of Alzheimer’s disease (AD). We create a hippocampal surface atlas with subfield information, model each hippocampus using the SPHARM technique, and register it to the atlas to extract surface deformation signals. We propose a new alternative to standard random field theory (RFT) and permutation image analysis methods, Statistical Parametric Mapping (SPM) Distribution Analysis or SPM-DA, to perform statistical shape analysis and compare its performance with that of RFT methods on both simulated and real hippocampal surface data. The major strengths of our framework are twofold: (a) SPM-DA provides potentially more powerful algorithms than standard RFT methods for detecting weak signals, and (b) the framework embraces the important hippocampal subfield information for improved biological interpretation. We demonstrate the effectiveness of our method via an application to an AD cohort, where an SPM-DA method detects meaningful hippocampal shape differences in EMCI that are undetected by standard RFT methods
Particle Correlations with Heavy Ions at LHC Energies
The ALICE detector will offer very good conditions to study the space-time characteristics of particle production in heavy-ion collisions at LHC from measurements of the correlation function of identical and non-identical particles at small relative velocities. The correlations - induced by Coulomb and nuclear final-state interactions - of non-identical particles appear to be directly sensitive to the space-time asymmetries of particle production allowing, in particular, a measurement of the mean relative delays in particle emission at time scales as small as few fm/c. The problem of Coulomb interaction of the correlated particles is particularly important in the case of the large effective volumes formed in ultra-relativistic heavy-ion reactions
Two-kaon correlations in central Pb + Pb collisions at 158 A GeV/c
Two-particle interferometry of positive kaons is studied in Pb + Pb
collisions at mean transverse momenta and 0.91 GeV/c. A
three-dimensional analysis was applied to the lower data, while a
two-dimensional analysis was used for the higher data. We find that the
source size parameters are consistent with the scaling curve observed in
pion correlation measurements in the same collisions, and that the duration
time of kaon emission is consistent with zero within the experimental
sensitivity.Comment: 4 pages incl. 1 table and 3 fig's; RevTeX; accepted for publication
in PR
Strange Meson Enhancement in PbPb Collisions
The NA44 Collaboration has measured yields and differential distributions of
K+, K-, pi+, pi- in transverse kinetic energy and rapidity, around the
center-of-mass rapidity in 158 A GeV/c Pb+Pb collisions at the CERN SPS. A
considerable enhancement of K+ production per pi is observed, as compared to
p+p collisions at this energy. To illustrate the importance of secondary hadron
rescattering as an enhancement mechanism, we compare strangeness production at
the SPS and AGS with predictions of the transport model RQMD.Comment: 11 pages, including 4 figures, LATE
- …
