    Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    Get PDF
    Background: Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. the aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB) using left internal thoracic artery (LITA).Methods: Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position); II (n = 33 intact pleural cavity). Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD) 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5.Results: in both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups.Conclusion: Subxyphoid insertion of pleural drain provides similar effects to preserved pleural integrity in pulmonary function, clinical outcomes, and thoracic pain after OPCAB. Therefore, our results support the hypothesis that once pleural cavities are incidentally or purposely opened during LITA dissection, subxyphoid placement of the pleural drain is recommended.Universidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Physiotherapy Sch, Dept Human Movement Sci, BR-11060001 Santos, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Pneumol Discipline, BR-04039002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Physiotherapy Sch, Dept Human Movement Sci, BR-11060001 Santos, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Pneumol Discipline, BR-04039002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilWeb of Scienc

    Energy-scaling behavior of intrinsic transverse-momentum parameters in Drell-Yan simulation

    Get PDF
    Data Availability: Release and preservation of data used by the CMS Collaboration as the basis for publications is guided by the CMS data preservation, re-use, and open access policy https://dx.doi.org/10.7483/OPENDATA.CMS.7347.JDWH .A preprint version of the article is available on arXiv, arXiv:2409.17770v2 [hep-ph] (https://arxiv.org/abs/2409.17770). [v2] Tue, 8 Apr 2025 23:23:48 UTC (450 KB). Comments: Replaced with the published version. Added the journal reference and the DOI. All the figures and tables can be found at https://cms-results.web.cern.ch/cms-results/public-results/publications/GEN-22-001 (CMS Public Pages). Subjects: High Energy Physics - Phenomenology (hep-ph); High Energy Physics - Experiment (hep-ex). Report numbers: CMS-GEN-22-001, CERN-EP-2024-216An analysis is presented based on models of the intrinsic transverse momentum (intrinsic ) of partons in nucleons by studying the dilepton transverse momentum in Drell-Yan events. Using parameter tuning in event generators and existing data from fixed-target experiments and from hadron colliders, our investigation spans 3 orders of magnitude in center-of-mass energy and 2 orders of magnitude in dilepton invariant mass. The results show an energy-scaling behavior of the intrinsic parameters, independent of the dilepton invariant mass at a given center-of-mass energy.We congratulate our colleagues in the CERN accelerator departments for the excellent performance of the LHC and thank the technical and administrative staffs at CERN and at other CMS institutes for their contributions to the success of the CMS effort. In addition, we gratefully acknowledge the computing centers and personnel of the Worldwide LHC Computing Grid and other centers for delivering so effectively the computing infrastructure essential to our analyses. Finally, we acknowledge the enduring support for the construction and operation of the LHC, the CMS detector, and the supporting computing infrastructure provided by the following funding agencies: SC (Armenia), BMBWF and FWF (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, FAPERGS, and FAPESP (Brazil); MES and BNSF (Bulgaria); CERN; CAS, MoST, and NSFC (China); MINCIENCIAS (Colombia); MSES and CSF (Croatia); RIF (Cyprus); SENESCYT (Ecuador); ERC PRG, RVTT3 and MoER TK202 (Estonia); Academy of Finland, MEC, and HIP (Finland); CEA and CNRS/IN2P3 (France); SRNSF (Georgia); BMBF, DFG, and HGF (Germany); GSRI (Greece); NKFIH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); MSIP and NRF (Republic of Korea); MES (Latvia); LMTLT (Lithuania); MOE and UM (Malaysia); BUAP, CINVESTAV, CONACYT, LNS, SEP, and UASLP-FAI (Mexico); MOS (Montenegro); MBIE (New Zealand); PAEC (Pakistan); MES and NSC (Poland); FCT (Portugal); MESTD (Serbia); MCIN/AEI and PCTI (Spain); MOSTR (Sri Lanka); Swiss Funding Agencies (Switzerland); MST (Taipei); MHESI and NSTDA (Thailand); TUBITAK and TENMAK (Turkey); NASU (Ukraine); STFC (United Kingdom); DOE and NSF (USA)

    The CMS Statistical Analysis and Combination Tool: Combine

    Get PDF
    Metrics: https://link.springer.com/article/10.1007/s41781-024-00121-4/metricsThis paper describes the Combine software package used for statistical analyses by the CMS Collaboration. The package, originally designed to perform searches for a Higgs boson and the combined analysis of those searches, has evolved to become the statistical analysis tool presently used in the majority of measurements and searches performed by the CMS Collaboration. It is not specific to the CMS experiment, and this paper is intended to serve as a reference for users outside of the CMS Collaboration, providing an outline of the most salient features and capabilities. Readers are provided with the possibility to run Combine and reproduce examples provided in this paper using a publicly available container image. Since the package is constantly evolving to meet the demands of ever-increasing data sets and analysis sophistication, this paper cannot cover all details of Combine. However, the online documentation referenced within this paper provides an up-to-date and complete user guide.CERN (European Organization for Nuclear Research)STFC (United Kingdom)Marie-Curie programme and the European Research Council and Horizon 2020 Grant, contract Nos. 675440, 724704, 752730, 758316, 765710, 824093, 101115353, 101002207, and COST Action CA16108 (European Union); the Leventis Foundation; the Alfred P. Sloan Foundatio

    Variation in hospital resource use and cost among surgical procedures using topical absorbable hemostats

    No full text
    Derek Martyn,1 Lisa M Meckley,1 Gavin Miyasato,1 Sangtaeck Lim,2 Jerome B Riebman,3 Richard Kocharian,3 Jillian G Scaife,1 Yajing Rao,1 Mitra Corral2 1Trinity Partners, LLC, Waltham, MA, USA; 2Global Health Economics and Market Access, Ethicon, Inc., Bridgewater, NJ, USA; 3Medical Affairs, Ethicon, Inc., Bridgewater, NJ, USA Background: Adjunctive hemostats are used to assist with the control of intraoperative bleeding. The most common types are flowables, gelatins, thrombins, and oxidized regenerated celluloses (ORCs). In the US, Surgicel® products are the only US Food and Drug Administration-approved ORCs. Objective: To compare the outcomes of health care resource utilization (HRU) and costs associated with using ORCs compared to other adjunctive hemostats (OAHs are defined as flowables, gelatins, and topical thrombins) for surgical procedures in the US inpatient setting. Patients and methods: A retrospective, US-based cohort study was conducted using hospital inpatient discharges from the 2011–2012 calendar years in the Premier Healthcare Database. Patients with either an ORC or an OAH who underwent a cardiovascular procedure (valve surgery and/or coronary artery bypass graft surgery), carotid endarterectomy, cholecystectomy, or hysterectomy were included. Propensity score matching was used to create comparable groups of ORC and OAH patients. Clinical, economic, and HRU outcomes were compared. Results: The propensity score matching created balanced patient cohorts for cardiovascular procedure (22,718 patients), carotid endarterectomy (10,890 patients), cholecystectomy (6,090 patients), and hysterectomy (9,348 patients). In all procedures, hemostatic agent costs were 28%–56% lower for ORCs, and mean hemostat units per discharge were 16%–41% lower for ORCs compared to OAHs. Length of stay and total procedure costs for patients treated with ORCs were lower for carotid endarterectomy patients (0.3 days and US700)andforcholecystectomypatients(1dayandUS700) and for cholecystectomy patients (1 day and US3,350) (all P<0.001). Conclusion: Costs and HRU for patients treated with ORCs were lower than or similar to patients treated with OAHs. Proper selection of the appropriate hemostatic agents has the potential to influence clinical outcomes and treatment costs. Keywords: hemostatics, hemostatic techniques, blood transfusion, health care costs, surgical blood los

    Measurements of inclusive and differential cross sections for top quark production in association with a Z boson in proton-proton collisions at √s=13 TeV

    No full text

    Search for light long-lived particles decaying to displaced jets in proton-proton collisions at √s=13.6TeV

    No full text

    Search for long-lived heavy neutral leptons in proton-proton collision events with a lepton-jet pair associated with a secondary vertex at √s=13 TeV

    No full text

    Search for heavy neutral leptons in final states with electrons, muons, and hadronically decaying tau leptons in proton-proton collisions at √s=13 TeV

    No full text

    Observation of the J/ψψ \to μ+μμ+μμ^+μ^-μ^+μ^- decay in proton-proton collisions at s\sqrt{s} = 13 TeV

    No full text
    A preprint version of the article is available at arXiv:2403.11352v2 [hep-ex], https://arxiv.org/abs/2403.11352. Comments: Replaced with the published version. Added the journal reference and the DOI. All the figures and tables can be found at https://cms-results.web.cern.ch/cms-results/public-results/publications/BPH-22-006 (CMS Public Pages). Report number: CMS-BPH-22-006, CERN-EP-2024-058.The /→+⁢−⁢+⁢− decay has been observed with a statistical significance in excess of five standard deviations. The analysis is based on an event sample of proton-proton collisions at a center-of-mass energy of 13 TeV, collected by the CMS experiment in 2018 and corresponding to an integrated luminosity of 33.6  fb−1. Normalizing to the /→+⁢− decay mode leads to a branching fraction of [10.1+3.3 −2.7⁢(stat)±0.4⁢(syst)]×10−7, a value that is consistent with the standard model prediction.SCOAP3

    Measurement of the t(t)over-barH and tH production rates in the H →b(b)over-bar decay channel using proton-proton collision data at √s=13 TeV

    No full text
    corecore