182 research outputs found
A Model of Temporal Intensity Modulation for Laser Generated Ultrasound
Q-switched lasers are often used as a non-contact ultrasound source in non-destructive evaluation (NDE) of materials [1]. Q-switched lasers typically have ns pulse durations and generate broadband ultrasound waves, though longer laser pulses, of 100 microseconds or greater, have also been used [2] for NDE. These longer pulses tend to produce somewhat lower center frequencies than do Q-switched pulses, though they are still a broadband source. But it would be desirable in some NDE applications to narrow the signal bandwidth to improve the signal to noise ration (SNR), and also to have direct control over the center frequency of the generated ultrasound. In principle, this may be achieved by temporal [3,4] or spatial modulation [5,6] of the laser pulse, or both [7]. The purpose of this work was to develop a numerical model of a single, temporally modulated laser source of ultrasound in the thermoelastic regime, for isotropic metals
Metabolic responses to high pCO2 conditions at a CO2 vent site in juveniles of a marine isopod species assemblage
We are starting to understand the relationship between metabolic rate responses and species' ability to respond to exposure to high pCO2. However, most of our knowledge has come from investigations of single species. The examination of metabolic responses of closely related species with differing distributions around natural elevated CO2 areas may be useful to inform our understanding of their adaptive significance. Furthermore, little is known about the physiological responses of marine invertebrate juveniles to high pCO2, despite the fact they are known to be sensitive to other stressors, often acting as bottlenecks for future species success. We conducted an in situ transplant experiment using juveniles of isopods found living inside and around a high pCO2 vent (Ischia, Italy): the CO2 'tolerant' Dynamene bifida and 'sensitive' Cymodoce truncata and Dynamene torelliae. This allowed us to test for any generality of the hypothesis that pCO2 sensitive marine invertebrates may be those that experience trade-offs between energy metabolism and cellular homoeostasis under high pCO2 conditions. Both sensitive species were able to maintain their energy metabolism under high pCO2 conditions, but in C. truncata this may occur at the expense of [carbonic anhydrase], confirming our hypothesis. By comparison, the tolerant D. bifida appeared metabolically well adapted to high pCO2, being able to upregulate ATP production without recourse to anaerobiosis. These isopods are important keystone species; however, given they differ in their metabolic responses to future pCO2, shifts in the structure of the marine ecosystems they inhabit may be expected under future ocean acidification conditions
A Linear Systems Approach to Laser Generation of Ultrasound in Composites
Laser ultrasonic generation and detection systems have been shown to be effective in the inspection and evaluation of both metals and composite materials [1–3]. Advantages of these noncontact systems include rapid scanning capability, the inspection of parts with complex geometries, and the ability for use in hostile environments. Unfortunately, laser ultrasonic systems are somewhat less sensitive than conventional contact piezoelectric systems. In order to increase the sensitivity, careful consideration must be paid to the choice of both generation and detection laser systems. Although the sensitivity of current laser ultrasonic systems has been shown to be sufficient for several applications, small improvements may allow for a more wide-spread use.</p
Two spatiotemporally distinct value systems shape reward-based learning in the human brain
Avoiding repeated mistakes and learning to reinforce rewarding decisions is critical for human survival and adaptive actions. Yet, the neural underpinnings of the value systems that encode different decision-outcomes remain elusive. Here coupling single-trial electroencephalography with simultaneously acquired functional magnetic resonance imaging, we uncover the spatiotemporal dynamics of two separate but interacting value systems encoding decision-outcomes. Consistent with a role in regulating alertness and switching behaviours, an early system is activated only by negative outcomes and engages arousal-related and motor-preparatory brain structures. Consistent with a role in reward-based learning, a later system differentially suppresses or activates regions of the human reward network in response to negative and positive outcomes, respectively. Following negative outcomes, the early system interacts and downregulates the late system, through a thalamic interaction with the ventral striatum. Critically, the strength of this coupling predicts participants’ switching behaviour and avoidance learning, directly implicating the thalamostriatal pathway in reward-based learning
Frequency-Shifted Low-Noise Sagnac Sensor for Ultrasonic Measurements
Laser generation of ultrasound and the subsequent detection of the ultrasonic waves using laser interferometry are areas of active research [1–6]. In earlier papers, the present authors have discussed an LBU system which employs a diffraction grating for illumination of a line-array to generate narrow-band surface waves and Lamb waves [4], and a fiberized heterodyne dual-probe laser interferometer to measure signals [3]. This paper reports progress towards the development of a robust low cost fiberized Sagnac laser interferometer suitable for field applications. Bowers first reported [7] the use of a Sagnac-type interferometer for surface acoustic wave detection, and the present authors have previously reported [8 QNDE 95] a variant of that scheme. In this paper, we present an alternative lower noise system that uses low cost, long coherence He-Ne lasers that have better intensity noise characteristics than typically used laser diodes. A scheme for elimination of a parasitic interference utilizing a frequency shifting technique has been developed. The primary advantage of the Sagnac interferometer is that it is exactly path matched and as such requires no heterodyning or static path compensation for sensor stabilization. The Sagnac interferometer described below is suitable for the measurement of ultrasonic surface waves arising from laser- or PZT-generated sources or from acoustic emissions. The laser-based ultrasonics (LBU) system can be used to detect and characterize discrete defects such as cracks.</p
Polyethylene thickness is a risk factor for wear necessitating insert exchange
PURPOSE: The aim of this observational study was to investigate the optimal minimal polyethylene (PE) thickness in total knee arthroplasty (TKA) and identify other risk factors associated with revision of the insert due to wear. METHODS: A total of 84 TKA were followed for 11-16 years. All patients received the same prosthesis design (Interax; Howmedica/ Stryker) with halfbearings: separate PE-inserts medially and laterally. Statistical analysis comprised Cox-regression to correct for confounding. RESULTS: Eight knees (9.5%) had been revised due to thinning inserts and an additional patient is scheduled for revision. PE thickness, diagnosis, BMI and weight are risk factors for insert exchange. For each millimetre decrease in PE thickness, the risk of insert exchange increases 3.0 times, which remains after correction for age, gender, weight, diagnosis and femoral-tibial angle. Insert exchange was 4.73 times more likely in OA-patients compared to RA-patients. For every unit increase in BMI and weight the risk for insert exchange increases 1.40 times and 1.14 times, respectively. CONCLUSIONS: In conclusion we therefore advise against the use of thin PE inserts in modular TKA and recommend PE inserts with a minimal 8-mm thickness.Optimising joint reconstruction management in arthritis and bone tumour patient
Low-Temperature III–V Direct Wafer Bonding Surface Preparation Using a UV-Sulfur Process
Effects of elevated seawater pCO2 on gene expression patterns in the gills of the green crab, Carcinus maenas
Background: The green crab Carcinus maenas is known for its high acclimation potential to varying environmental
abiotic conditions. A high ability for ion and acid-base regulation is mainly based on an efficient regulation
apparatus located in gill epithelia. However, at present it is neither known which ion transport proteins play a key
role in the acid-base compensation response nor how gill epithelia respond to elevated seawater pCO2 as
predicted for the future. In order to promote our understanding of the responses of green crab acid-base
regulatory epithelia to high pCO2, Baltic Sea green crabs were exposed to a pCO2 of 400 Pa. Gills were screened
for differentially expressed gene transcripts using a 4,462-feature microarray and quantitative real-time PCR.
Results: Crabs responded mainly through fine scale adjustment of gene expression to elevated pCO2. However, 2%
of all investigated transcripts were significantly regulated 1.3 to 2.2-fold upon one-week exposure to CO2 stress.
Most of the genes known to code for proteins involved in osmo- and acid-base regulation, as well as cellular stress
response, were were not impacted by elevated pCO2. However, after one week of exposure, significant changes
were detected in a calcium-activated chloride channel, a hyperpolarization activated nucleotide-gated potassium
channel, a tetraspanin, and an integrin. Furthermore, a putative syntaxin-binding protein, a protein of the
transmembrane 9 superfamily, and a Cl-/HCO3
- exchanger of the SLC 4 family were differentially regulated. These
genes were also affected in a previously published hypoosmotic acclimation response study.
Conclusions: The moderate, but specific response of C. maenas gill gene expression indicates that (1) seawater
acidification does not act as a strong stressor on the cellular level in gill epithelia; (2) the response to hypercapnia
is to some degree comparable to a hypoosmotic acclimation response; (3) the specialization of each of the
posterior gill arches might go beyond what has been demonstrated up to date; and (4) a re-configuration of gill
epithelia might occur in response to hypercapnia
The creatine kinase system and pleiotropic effects of creatine
The pleiotropic effects of creatine (Cr) are based mostly on the functions of the enzyme creatine kinase (CK) and its high-energy product phosphocreatine (PCr). Multidisciplinary studies have established molecular, cellular, organ and somatic functions of the CK/PCr system, in particular for cells and tissues with high and intermittent energy fluctuations. These studies include tissue-specific expression and subcellular localization of CK isoforms, high-resolution molecular structures and structure–function relationships, transgenic CK abrogation and reverse genetic approaches. Three energy-related physiological principles emerge, namely that the CK/PCr systems functions as (a) an immediately available temporal energy buffer, (b) a spatial energy buffer or intracellular energy transport system (the CK/PCr energy shuttle or circuit) and (c) a metabolic regulator. The CK/PCr energy shuttle connects sites of ATP production (glycolysis and mitochondrial oxidative phosphorylation) with subcellular sites of ATP utilization (ATPases). Thus, diffusion limitations of ADP and ATP are overcome by PCr/Cr shuttling, as most clearly seen in polar cells such as spermatozoa, retina photoreceptor cells and sensory hair bundles of the inner ear. The CK/PCr system relies on the close exchange of substrates and products between CK isoforms and ATP-generating or -consuming processes. Mitochondrial CK in the mitochondrial outer compartment, for example, is tightly coupled to ATP export via adenine nucleotide transporter or carrier (ANT) and thus ATP-synthesis and respiratory chain activity, releasing PCr into the cytosol. This coupling also reduces formation of reactive oxygen species (ROS) and inhibits mitochondrial permeability transition, an early event in apoptosis. Cr itself may also act as a direct and/or indirect anti-oxidant, while PCr can interact with and protect cellular membranes. Collectively, these factors may well explain the beneficial effects of Cr supplementation. The stimulating effects of Cr for muscle and bone growth and maintenance, and especially in neuroprotection, are now recognized and the first clinical studies are underway. Novel socio-economically relevant applications of Cr supplementation are emerging, e.g. for senior people, intensive care units and dialysis patients, who are notoriously Cr-depleted. Also, Cr will likely be beneficial for the healthy development of premature infants, who after separation from the placenta depend on external Cr. Cr supplementation of pregnant and lactating women, as well as of babies and infants are likely to be of benefit for child development. Last but not least, Cr harbours a global ecological potential as an additive for animal feed, replacing meat- and fish meal for animal (poultry and swine) and fish aqua farming. This may help to alleviate human starvation and at the same time prevent over-fishing of oceans
- …
