14 research outputs found
Adding value to laboratory medicine: a professional responsibility
Laboratory medicine is a medical specialty at the centre of healthcare. When used optimally laboratory medicine generates knowledge that can facilitate patient safety, improve patient outcomes, shorten patient journeys and lead to more cost-effective healthcare. Optimal use of laboratory medicine relies on dynamic and authoritative leadership outside as well as inside the laboratory. The first responsibility of the head of a clinical laboratory is to ensure the provision of a high quality service across a wide range of parameters culminating in laboratory accreditation against an international standard, such as ISO 15189. From that essential baseline the leadership of laboratory medicine at local, national and international level needs to ‘add value’ to ensure the optimal delivery, use, development and evaluation of the services provided for individuals and for groups of patients. A convenient tool to illustrate added value is use of the mnemonic ‘SCIENCE’. This tool allows added value to be considered in seven domains: standardisation and harmonisation; clinical effectiveness; innovation; evidence-based practice; novel applications; cost-effectiveness; and education of others. The assessment of added value in laboratory medicine may be considered against a framework that comprises three dimensions: operational efficiency; patient management; and patient behaviours. The profession and the patient will benefit from sharing examples of adding value to laboratory medicine
FUNCTION SIGNATURE AUTHORIZED
1/5 TITLE: PROCESS FOR VERIFICATION AND PUBLICATION OF CALIBRATION AN
Optimizing available tools for achieving result standardization : value added by joint committee on traceability in laboratory medicine (JCTLM)
BACKGROUND: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community.
CONTENT: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined.
SUMMARY: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU. Results showed that traceability to higher-order references can be established by IVD manufacturers within the defined APS for most of the 13 selected measurands. However, some measurands do not yet have suitable CRMs for use as common calibrators. For these measurands, splitting clinical samples with a laboratory performing the RMP may provide a practical alternative for establishing a calibration hierarchy
Feasibility of metrological traceability implementation using the joint committee on traceability in laboratory medicine database entries including the fulfillment of "fit-for-purpose" maximum allowable measurement uncertainty
Background : In previous publications, the Task Force on Reference Measurement System Implementation proposed a procedural approach combining a critical review of entries available in the Joint Committee on Traceability in Laboratory Medicine (JCTLM) database with a comparison of this information against analytical performance specifications for measurement uncertainty (MU) and applied it to a group of 13 measurands.Content : Here we applied this approach to 17 additional measurands, of which measurements are frequently requested. The aims of the study were (a) to describe the main characteristics for implementing traceability and the potential to fulfill the maximum allowable MU (MAU) at the clinical sample level of certified reference materials and reference measurement procedures listed in the JCTLM database; (b) to discuss limitations and obstacles, if any, to the achievement of the required quality of laboratory measurements; and (c) to provide a gap analysis by highlighting what is still missing in the database. Results were integrated with those obtained in the previous study, therefore offering an overview of where we are and what is still missing in the practical application of the metrological traceability concept to 30 common biochemical tests employed in laboratory medicine.Summary : Our analysis shows that for 28 out of 30 measurands, conditions exist to correctly implement metrological traceability to the International System of units and fulfill at least the MAU of the minimum quality level derived according to internationally recommended models. For 2 measurands (serum albumin and chloride), further improvements in MU of higher-order references would be necessary.Background : In previous publications, the Task Force on Reference Measurement System Implementation proposed a procedural approach combining a critical review of entries available in the Joint Committee on Traceability in Laboratory Medicine (JCTLM) database with a comparison of this information against analytical performance specifications for measurement uncertainty (MU) and applied it to a group of 13 measurands.Content : Here we applied this approach to 17 additional measurands, of which measurements are frequently requested. The aims of the study were (a) to describe the main characteristics for implementing traceability and the potential to fulfill the maximum allowable MU (MAU) at the clinical sample level of certified reference materials and reference measurement procedures listed in the JCTLM database; (b) to discuss limitations and obstacles, if any, to the achievement of the required quality of laboratory measurements; and (c) to provide a gap analysis by highlighting what is still missing in the database. Results were integrated with those obtained in the previous study, therefore offering an overview of where we are and what is still missing in the practical application of the metrological traceability concept to 30 common biochemical tests employed in laboratory medicine.Summary : Our analysis shows that for 28 out of 30 measurands, conditions exist to correctly implement metrological traceability to the International System of units and fulfill at least the MAU of the minimum quality level derived according to internationally recommended models. For 2 measurands (serum albumin and chloride), further improvements in MU of higher-order references would be necessary.A
