464 research outputs found

    Rationale and study design of the Prospective comparison of Angiotensin Receptor neprilysin inhibitor with Angiotensin receptor blocker MEasuring arterial sTiffness in the eldERly (PARAMETER) study.

    Get PDF
    Hypertension in elderly people is characterised by elevated systolic blood pressure (SBP) and increased pulse pressure (PP), which indicate large artery ageing and stiffness. LCZ696, a first-in-class angiotensin receptor neprilysin inhibitor (ARNI), is being developed to treat hypertension and heart failure. The Prospective comparison of Angiotensin Receptor neprilysin inhibitor with Angiotensin receptor blocker MEasuring arterial sTiffness in the eldERly (PARAMETER) study will assess the efficacy of LCZ696 versus olmesartan on aortic stiffness and central aortic haemodynamics

    The EPICure study: association between hemodynamics and lung function at 11 years after extremely preterm birth.

    Get PDF
    To investigate the relationship between disturbed lung function and large-artery hemodynamics in school-age children born extremely preterm (EP) (at 25 completed weeks of gestation or less)

    APPROACH BY GREAT WHITE SHARK ELICITS FLIGHT RESPONSE IN BOTTLENOSE DOLPHINS

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75252/1/j.1748-7692.1996.tb00074.x.pd

    Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization

    Get PDF
    The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper arm assumed the pressure obtained by this technique was a good proxy for central aortic BP.1,2 The clinical (prognostic) importance of brachial cuff BP is undeniable for both the assessment of cardiovascular risk associated with elevated BP and the benefits of treatment-induced BP reduction.3 However, it is also generally appreciated that peripheral artery systolic BP (SBP; brachial or radial artery) may be an inaccurate substitute for central SBP.4 This has been reported in human studies using intra-arterial catheterization of peripheral and central arteries.5–8 There may also be a discrepancy between peripheral and central BP responses to vasoactive drugs.9 These findings are corroborated in larger studies using non-invasive central aortic BP methods,10–13 and, while yet to be fully adopted in clinical practice, an independent prognostic value of central BP has been demonstrated.14–16 Altogether, there is a growing interest among clinicians towards improving risk estimates by using devices that provide more accurate measures of central aortic BP than those provided by current brachial cuff BP methods. Many non-invasive devices have been developed that purport to estimate central BP from different peripheral artery sites (e.g. radial, brachial, carotid arteries) using different principles of recording the pressure or surrogate signals (e.g. applanation tonometry, oscillometry, ultrasound, or magnetic resonance imaging) and different calibration methods to derive central BP. Since upper arm cuff-based devices to estimate central BP are more clinically appealing, in recent years several companies have developed such devices using a variety of techniques (e.g. oscillometric sub-diastolic or supra-systolic waveform analysis with generalized transfer functions), which employ a variety of signal processing steps to estimate central BP from peripheral signals.17,18 Yet, with no standardized guidelines,17 the accuracy testing of these new devices (as well as the preceding devices) has not been undertaken in a uniform fashion with comparable protocols, emphasizing the need for guidance in this field.19–22 An international task force was convened to address this situation

    Current challenges facing the assessment of the allergenic capacity of food allergens in animal models

    Get PDF
    Food allergy is a major health problem of increasing concern. The insufficiency of protein sources for human nutrition in a world with a growing population is also a significant problem. The introduction of new protein sources into the diet, such as newly developed innovative foods or foods produced using new technologies and production processes, insects, algae, duckweed, or agricultural products from third countries, creates the opportunity for development of new food allergies, and this in turn has driven the need to develop test methods capable of characterizing the allergenic potential of novel food proteins. There is no doubt that robust and reliable animal models for the identification and characterization of food allergens would be valuable tools for safety assessment. However, although various animal models have been proposed for this purpose, to date, none have been formally validated as predictive and none are currently suitable to test the allergenic potential of new foods. Here, the design of various animal models are reviewed, including among others considerations of species and strain, diet, route of administration, dose and formulation of the test protein, relevant controls and endpoints measured

    Effects of Sacubitril/Valsartan Versus Olmesartan on Central Hemodynamics in the Elderly With Systolic Hypertension: The PARAMETER Study.

    Get PDF
    Effective treatment of systolic hypertension in elderly patients remains a major therapeutic challenge. A multicenter, double-blind, randomized controlled trial with sacubitril/valsartan (LCZ696), a first-in-class angiotensin receptor neprilysin inhibitor, was conducted to determine its effects versus olmesartan (angiotensin receptor blocker) on central aortic pressures, in elderly patients (aged ≥60 years) with systolic hypertension and pulse pressure >60 mm Hg, indicative of arterial stiffness. Patients (n=454; mean age, 67.7 years; mean seated systolic blood pressure, 158.6 mm Hg; mean seated pulse pressure, 69.7 mm Hg) were randomized to receive once-daily sacubitril/valsartan 200 mg or olmesartan 20 mg, force titrated to double the initial doses after 4 weeks, before primary assessment at 12 weeks. The study extended double-blind treatment for 12 to 52 weeks, during which amlodipine (2.5-5 mg) and subsequently hydrochlorothiazide (6.25-25 mg) were added-on for patients not achieving blood pressure target (<140/90). At week 12, sacubitril/valsartan reduced central aortic systolic pressure (primary assessment) greater than olmesartan by -3.7 mm Hg (P=0.010), further corroborated by secondary assessments at week 12 (central aortic pulse pressure, -2.4 mm Hg, P<0.012; mean 24-hour ambulatory brachial systolic blood pressure and central aortic systolic pressure, -4.1 mm Hg and -3.6 mm Hg, respectively, both P<0.001). Differences in 24-hour ambulatory pressures were pronounced during sleep. After 52 weeks, blood pressure parameters were similar between treatments (P<0.002); however, more patients required add-on antihypertensive therapy with olmesartan (47%) versus sacubitril/valsartan (32%; P<0.002). Both treatments were equally well tolerated. The PARAMETER study (Prospective Comparison of Angiotensin Receptor Neprilysin Inhibitor With Angiotensin Receptor Blocker Measuring Arterial Stiffness in the Elderly), for the first time, demonstrated superiority of sacubitril/valsartan versus olmesartan in reducing clinic and ambulatory central aortic and brachial pressures in elderly patients with systolic hypertension and stiff arteries

    Quantitative 18F-fluorodeoxyglucose positron emission tomography/computed tomography to assess pulmonary inflammation in COPD

    Get PDF
    RATIONALE: COPD and smoking are characterised by pulmonary inflammation. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging may improve knowledge of pulmonary inflammation in COPD patients and aid early development of novel therapies as an imaging biomarker. OBJECTIVES: To evaluate pulmonary inflammation, assessed by FDG uptake, in whole and regional lung in “usual” (smoking-related) COPD patients, alpha-1 antitrypsin deficiency (α1ATD) COPD patients, smokers without COPD and never-smokers using FDG PET/CT. Secondly, to explore cross-sectional associations between FDG PET/CT and systemic inflammatory markers in COPD patients and repeatability of the technique in COPD patients. METHODS: Data from two imaging studies were evaluated. Pulmonary FDG uptake (normalised Ki; nKi) was measured by Patlak graphical analysis in four subject groups: 84 COPD patients, 11 α1ATD-COPD patients, 12 smokers and 10 never-smokers. Within the COPD group, associations between nKi and systemic markers of inflammation were assessed. Repeatability was evaluated in 32 COPD patients comparing nKi values at baseline and at 4-month follow-up. RESULTS: COPD patients, α1ATD-COPD patients and smokers had increased whole lung FDG uptake (nKi) compared with never-smokers (0.0037±0.001, 0.0040±0.001, 0.0040±0.001 versus 0.0028±0.001 mL·cm−3·min−1, respectively, p<0.05 for all). Similar results were observed in upper and middle lung regions. In COPD participants, plasma fibrinogen was associated with whole lung nKi (β=0.30, p=0.02) in multivariate analysis adjusted for current smoking, forced expiratory volume in 1 s % predicted, systemic neutrophils and C-reactive protein levels. Mean percentage difference in nKi between the baseline and follow-up was 3.2%, and the within subject coefficient of variability was 7.7%. CONCLUSIONS: FDG PET/CT has potential as a noninvasive tool to enable whole lung and regional quantification of FDG uptake to assess smoking- and COPD-related pulmonary inflammation
    corecore