229 research outputs found

    Sudden Death and Left Ventricular Involvement in Arrhythmogenic Cardiomyopathy

    Get PDF
    BACKGROUND: Arrhythmogenic cardiomyopathy (ACM) is an inherited heart muscle disorder characterized by myocardial fibrofatty replacement and an increased risk of sudden cardiac death (SCD). Originally described as a right ventricular disease, ACM is increasingly recognized as a biventricular entity. We evaluated pathological, genetic, and clinical associations in a large SCD cohort. METHODS: We investigated 5205 consecutive cases of SCD referred to a national cardiac pathology center between 1994 and 2018. Hearts and tissue blocks were examined by expert cardiac pathologists. After comprehensive histological evaluation, 202 cases (4%) were diagnosed with ACM. Of these, 15 (7%) were diagnosed antemortem with dilated cardiomyopathy (n=8) or ACM (n=7). Previous symptoms, medical history, circumstances of death, and participation in competitive sport were recorded. Postmortem genetic testing was undertaken in 24 of 202 (12%). Rare genetic variants were classified according to American College of Medical Genetics and Genomics criteria. RESULTS: Of 202 ACM decedents (35.4±13.2 years; 82% male), no previous cardiac symptoms were reported in 157 (78%). Forty-one decedents (41/202; 20%) had been participants in competitive sport. The adjusted odds of dying during physical exertion were higher in men than in women (odds ratio, 4.58; 95% CI, 1.54-13.68; P=0.006) and in competitive athletes in comparison with nonathletes (odds ratio, 16.62; 95% CI, 5.39-51.24; P<0.001). None of the decedents with an antemortem diagnosis of dilated cardiomyopathy fulfilled definite 2010 Task Force criteria. The macroscopic appearance of the heart was normal in 40 of 202 (20%) cases. There was left ventricular histopathologic involvement in 176 of 202 (87%). Isolated right ventricular disease was seen in 13%, isolated left ventricular disease in 17%, and biventricular involvement in 70%. Among whole hearts, the most common areas of fibrofatty infiltration were the left ventricular posterobasal (68%) and anterolateral walls (58%). Postmortem genetic testing yielded pathogenic variants in ACM-related genes in 6 of 24 (25%) decedents. CONCLUSIONS: SCD attributable to ACM affects men predominantly, most commonly occurring during exertion in athletic individuals in the absence of previous reported cardiac symptoms. Left ventricular involvement is observed in the vast majority of SCD cases diagnosed with ACM at autopsy. Current Task Force criteria may fail to diagnose biventricular ACM before death

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Sensitivity of an Ultrasonic Technique for Axial Stress Determination

    Get PDF
    In machine assembly it is often required that bolts used to fasten machine parts be installed with specific design preloads. Because it is inconvenient to measure preload directly, preload specifications are usually based on some more easily measured quantity with which the level of preload may be correlated. Most often this quantity is the torque to be applied to the bolt at installation. Studies by Blake and Kurtz [1] and Heyman [2] have shown that when bolts are torqued into place, the fraction of applied torque which translates into useful preload is small and widely variable. This is so because the large majority of applied torque is absorbed in overcoming friction in the bolt’s threads and at the underside of the bolt’s head. Consequently, even though the torque to install different bolts may be identical, small variations in frictional conditions from one installation to the next can result in large variations in preload. The unreliability of torque as an indicator of preload has been the motivating factor behind the development of a number of alternate methods of measurement [2–5]

    Posterior Decompression and Fusion: Whole-Spine Functional and Clinical Outcomes

    Get PDF
    The mobility of the spine and the change in the angle of the curvatures are directly related to spinal pain and spinal stenosis. The aim of the study was the evaluation of morphology and mobility of the spine in patients who were subjected to decompression and posterior fusion with pedicle screws. The treatment group consisted of 20 patients who underwent posterior fixation of lumbar spine (one and two level fusion). The control group consisted of 39 healthy subjects. Mobility and curvatures of the spine were measured with a non-invasive device, the Spinal Mouse. Pain was evaluated with the Visual Analogue Scale (VAS). The Oswestry Disability Index (ODI) and the SF-36 were used to evaluate the degree of the functional disability and the quality of life, respectively. The measurements were recorded preoperatively and at 3, 6 and 12 months postoperatively. The mobility of the lumbar spine in the sagittal plane increased (p = 0.009) at 12 months compared to the measurements at 3 months. The mobility of the thoracic spine in the frontal plane increased (p = 0.009) at 12 months compared to the preoperative evaluation. The results of VAS, ODI and SF-36 PCS improved significantly (p<0.001). The levels of fusion exhibited a strong linear correlation (r = 0.651, p = 0.002) with the total trunk inclination in the upright position. Although pain, quality of life and spinal mobility in the sagittal and frontal planes significantly improved in the treatment group, these patients still had limited mobility and decreased curves/angles values compared to control group

    Ultrasonic Monitoring of Reaction Bonding Silicon Nitride

    Get PDF
    A method is discussed to use ultrasonic techniques to monitor the reaction bonding of silicon nitride. Reaction bonding takes place in a nitrogen atmosphere heated up to 1390°C. As with many sensors used in hostile environments, it is difficult to design the ultrasonic sensor in a way that provides optimal clarity of the signal. The sensing system has to be designed within physical limitations on access to the furnace and it has to satisfy considerations on the design of a cooling system for the ultrasonic transducer. These limiting factors have been overcome so that ultrasonic signals have been obtained during processing, albeit with a significant noise level. Signal processing techniques have been developed which make it possible to obtain information on changes in phase velocity and attenuation during reaction bonding. The signal processing techniques have the potential to be implemented in real time for the monitoring of the progress of the reaction. This information can then be used for process control feedback.</p

    Undiagnosed osteoid osteoma of the spine presenting as painful scoliosis from adolescence to adulthood: a case report

    Get PDF
    Presented here is a case of a young woman, with an undiagnosed osteoid osteoma of the spine, which presented with painful scoliosis in adolescence and was treated by bracing until her accession to adulthood. A more thorough investigation, years after the initial one, revealed the tumor. Surgical excision and stabilization offered the long-awaited cure. Misdiagnosis resulted in intractable pain for years, deformity, the discomfort of brace therapy, and the frustration of a prolonged yet ineffective treatment

    Mechanisms of T cell organotropism

    Get PDF
    F.M.M.-B. is supported by the British Heart Foundation, the Medical Research Council of the UK and the Gates Foundation

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe

    Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data

    Get PDF
    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns
    corecore