5,872 research outputs found
Tip Allocation: A Compliance Study tor Restaurants
Survey research of the commercial food service industry with regard to tips and tip allocation revealed that 50 percent of restaurateurs require that employees report a minimum amount or percentage of sales and over 50 percent which allocate tips report them as employee income. The authors discuss these results and point out other problems
Trends in the availability and usage of electrophysical agents in physiotherapy practices from 1990 to 2010: A review
This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2012 Maney PublishingBackground: The use of electrophysical agents has a historically important role in physiotherapy practice. There are anecdotal reports that the availability and usage of electrotherapy modalities are declining, which may have implications for physiotherapy practice. The aim of this literature review was to provide scientific evidence on electrotherapy usage in the last 20 years by identifying trends in availability, use, and non-use of nine electrotherapeutic modalities in physiotherapy practices during 1990s and 2000s. Methods: Review of empirical studies published in the English language from 1990 to 2010 and identified through searching online bibliographic databases, which included: Medline/OvidSP, PubMed Central, CINAHL/EBSCOhost, ScienceDirect, Scopus, ISI Web of Science, and Google Scholar. Findings: In the last 20 years, ultrasound availability and usage show increasing trends in several countries. The availability and use of pulsed shortwave diathermy and laser have shown steady trends. Transcutaneous electrical nerve stimulation, interferential, and biofeedback availability and usage have shown increasing trends in the UK and decreasing trends in Australia and the Republic of Ireland. Trends of continuous shortwave diathermy availability and use are declining irrespective of the country of the study. The availability and usage of microwave diathermy and H-wave show steeply declining trends, while there is a sharp rise in their non-availability over the last several years. Conclusions: The availability and use of electrophysical agents have greatly changed in the last 20 years. Declining trends in the availability and usage along with increasing trend of non-availability of electrotherapy modalities may have implications for electrotherapy education, training, and practice in the coming years.This study was funded by Health & Safety Executive, UK (grant no. 4371/R47.022)
The value of source data verification in a cancer clinical trial
Background
Source data verification (SDV) is a resource intensive method of quality assurance frequently used in clinical trials. There is no empirical evidence to suggest that SDV would impact on comparative treatment effect results from a clinical trial.
Methods
Data discrepancies and comparative treatment effects obtained following 100% SDV were compared to those based on data without SDV. Overall survival (OS) and Progression-free survival (PFS) were compared using Kaplan-Meier curves, log-rank tests and Cox models. Tumour response classifications and comparative treatment Odds Ratios (ORs) for the outcome objective response rate, and number of Serious Adverse Events (SAEs) were compared. OS estimates based on SDV data were compared against estimates obtained from centrally monitored data.
Findings
Data discrepancies were identified between different monitoring procedures for the majority of variables examined, with some variation in discrepancy rates. There were no systematic patterns to discrepancies and their impact was negligible on OS, the primary outcome of the trial (HR (95% CI): 1.18(0.99 to 1.41), p = 0.064 with 100% SDV; 1.18(0.99 to 1.42), p = 0.068 without SDV; 1.18(0.99 to 1.40), p = 0.073 with central monitoring). Results were similar for PFS. More extreme discrepancies were found for the subjective outcome overall objective response (OR (95% CI): 1.67(1.04 to 2.68), p = 0.03 with 100% SDV; 2.45(1.49 to 4.04), p = 0.0003 without any SDV) which was mostly due to differing CT scans.
Interpretation
Quality assurance methods used in clinical trials should be informed by empirical evidence. In this empirical comparison, SDV was expensive and identified random errors that made little impact on results and clinical conclusions of the trial. Central monitoring using an external data source was a more efficient approach for the primary outcome of OS. For the subjective outcome objective response, an independent blinded review committee and tracking system to monitor missing scan data could be more efficient than SDV
Characterization of Shewanella oneidensis MtrC: a cell-surface decaheme cytochrome involved in respiratory electron transport to extracellular electron acceptors
MtrC is a decaheme c-type cytochrome associated with the outer cell membrane of Fe(III)-respiring species of the Shewanella genus. It is proposed to play a role in anaerobic respiration by mediating electron transfer to extracellular mineral oxides that can serve as terminal electron acceptors. The present work presents the first spectropotentiometric and voltammetric characterization of MtrC, using protein purified from Shewanella oneidensis MR-1. Potentiometric titrations, monitored by UV–vis absorption and electron paramagnetic resonance (EPR) spectroscopy, reveal that the hemes within MtrC titrate over a broad potential range spanning between approximately +100 and approximately -500 mV (vs. the standard hydrogen electrode). Across this potential window the UV–vis absorption spectra are characteristic of low-spin c-type hemes and the EPR spectra reveal broad, complex features that suggest the presence of magnetically spin-coupled low-spin c-hemes. Non-catalytic protein film voltammetry of MtrC demonstrates reversible electrochemistry over a potential window similar to that disclosed spectroscopically. The voltammetry also allows definition of kinetic properties of MtrC in direct electron exchange with a solid electrode surface and during reduction of a model Fe(III) substrate. Taken together, the data provide quantitative information on the potential domain in which MtrC can operate
Engaging with community researchers for exposure science: lessons learned from a pesticide biomonitoring study
A major challenge in biomonitoring studies with members of the general public is ensuring their continued involvement throughout the necessary length of the research. The paper presents evidence on the use of community researchers, recruited from local study areas, as a mechanism for ensuring effective recruitment and retention of farmer and resident participants for a pesticides biomonitoring study. The evidence presented suggests that community researchers' abilities to build and sustain trusting relationships with participants enhanced the rigour of the study as a result of their on-the-ground responsiveness and flexibility resulting in data collection beyond targets expected
Bisphenol A exposure in Mexico City and risk of prematurity: a pilot nested case control study
Abstract Background Presence of Bisphenol A (BPA) has been documented worldwide in a variety of human biological samples. There is growing evidence that low level BPA exposure may impact placental tissue development and thyroid function in humans. The aim of this present pilot study was to determine urinary concentrations of BPA during the last trimester of pregnancy among a small subset of women in Mexico City, Mexico and relate these concentrations to risk of delivering prematurely. Methods A nested case-control subset of 60 participants in the Early Life Exposure in Mexico to ENvironmental Toxicants (ELEMENT) study in Mexico City, Mexico were selected based on delivering less than or equal to 37 weeks of gestation and greater than 37 weeks of gestation. Third trimester archived spot urine samples were analyzed by online solid phase extraction coupled with high performance liquid chromatography isotope dilution tandem mass spectrometry. Results BPA was detected in 80.0% (N = 48) of the urine samples; total concentrations ranged from < 0.4 μg/L to 6.7 μg/L; uncorrected geometric mean was 1.52 μg/L. The adjusted odds ratio of delivering less than or equal to 37 weeks in relation to specific gravity adjusted third trimester BPA concentration was 1.91 (95%CI 0.93, 3.91, p-value = 0.08). When cases were further restricted to births occurring prior to the 37th week (n = 12), the odds ratio for specific-gravity adjusted BPA was larger and statistically significant (p < 0.05). Conclusions This is the first study to document measurable levels of BPA in the urine of a population of Mexican women. This study also provides preliminary evidence, based on a single spot urine sample collected during the third trimester, that pregnant women who delivered less than or equal to 37 weeks of gestation and prematurely (< 37 weeks) had higher urinary concentrations of BPA compared to women delivering after 37 weeks.http://deepblue.lib.umich.edu/bitstream/2027.42/78251/1/1476-069X-9-62.xmlhttp://deepblue.lib.umich.edu/bitstream/2027.42/78251/2/1476-069X-9-62.pdfPeer Reviewe
In-cell NMR characterization of the secondary structure populations of a disordered conformation of α-Synuclein within E. coli cells
α-Synuclein is a small protein strongly implicated in the pathogenesis of Parkinson’s disease and related neurodegenerative disorders. We report here the use of in-cell NMR spectroscopy to observe directly the structure and dynamics of this protein within E. coli cells. To improve the accuracy in the measurement of backbone chemical shifts within crowded in-cell NMR spectra, we have developed a deconvolution method to reduce inhomogeneous line broadening within cellular samples. The resulting chemical shift values were then used to evaluate the distribution of secondary structure populations which, in the absence of stable tertiary contacts, are a most effective way to describe the conformational fluctuations of disordered proteins. The results indicate that, at least within the bacterial cytosol, α-synuclein populates a highly dynamic state that, despite the highly crowded environment, has the same characteristics as the disordered monomeric form observed in aqueous solution
An assessment of validity and responsiveness of generic measures of health-related quality of life in hearing impairment
This article is made available through the Brunel Open Access Publishing Fund. This article is distributed under the terms of the
Creative Commons Attribution License which permits any use, distribution,
and reproduction in any medium, provided the original
author(s) and the source are credited.Purpose: This review examines psychometric performance of three widely used generic preference-based measures, that is, EuroQol 5 dimensions (EQ-5D), Health Utility Index 3 (HUI3) and Short-form 6 dimensions (SF-6D) in patients with hearing impairments.
Methods: A systematic search was undertaken to identify studies of patients with hearing impairments where health state utility values were measured and reported. Data were extracted and analysed to assess the reliability, validity (known group differences and convergent validity) and responsiveness of the measures across hearing impairments.
Results: Fourteen studies (18 papers) were included in the review. HUI3 was the most commonly used utility measures in hearing impairment. In all six studies, the HUI3 detected difference between groups defined by the severity of impairment, and four out of five studies detected statistically significant changes as a result of intervention. The only study available suggested that EQ-5D only had weak ability to discriminate difference between severity groups, and in four out of five studies, EQ-5D failed to detected changes. Only one study involved the SF-6D; thus, the information is too limited to conclude on its performance. Also evidence for the reliability of these measures was not found.
Conclusion: Overall, the validity and responsiveness of the HUI3 in hearing impairment was good. The responsiveness of EQ-5D was relatively poor and weak validity was suggested by limited evidence. The evidence on SF-6D was too limited to make any judgment. More head-to-head comparisons of these and other preference measures of health are required.Medical Research Counci
Comparison of serious inhaler technique errors made by device-naïve patients using three different dry powder inhalers: a randomised, crossover, open-label study
Background: Serious inhaler technique errors can impair drug delivery to the lungs. This randomised, crossover, open-label study evaluated the proportion of patients making predefined serious errors with Pulmojet compared with Diskus and Turbohaler dry powder inhalers. Methods: Patients ≥18 years old with asthma and/or COPD who were current users of an inhaler but naïve to the study devices were assigned to inhaler technique assessment on Pulmojet and either Diskus or Turbohaler in a randomised order. Patients inhaled through empty devices after reading the patient information leaflet. If serious errors potentially affecting dose delivery were recorded, they repeated the inhalations after watching a training video. Inhaler technique was assessed by a trained nurse observer and an electronic inhalation profile recorder. Results: Baseline patient characteristics were similar between randomisation arms for the Pulmojet-Diskus (n = 277) and Pulmojet-Turbohaler (n = 144) comparisons. Non-inferiority in the proportions of patients recording no nurse-observed serious errors was demonstrated for both Pulmojet versus Diskus, and Pulmojet versus Turbohaler; therefore, superiority was tested. Patients were significantly less likely to make ≥1 nurse-observed serious errors using Pulmojet compared with Diskus (odds ratio, 0.31; 95 % CI, 0.19–0.51) or Pulmojet compared with Turbohaler (0.23; 0.12–0.44) after reading the patient information leaflet with additional video instruction, if required. Conclusions These results suggest Pulmojet is easier to learn to use correctly than the Turbohaler or Diskus for current inhaler users switching to a new dry powder inhaler
- …