1,848 research outputs found

    Anisotropy in nanocellular polymers promoted by the addition of needle‐like sepiolites

    Get PDF
    This work presents a new strategy for obtaining nanocellular materials with high anisotropy ratios by means of the addition of needle‐like nanoparticles. Nanocellular polymers are of great interest due to their outstanding properties, whereas anisotropic structures allow the realization of improved thermal and mechanical properties in certain directions. Nanocomposites based on poly(methyl methacrylate) (PMMA) with nanometric sepiolites are generated by extrusion. From the extruded filaments, cellular materials are produced using a two‐step gas dissolution foaming method. The effect of adding various types and contents of sepiolites is investigated. As a result of the extrusion process, the needle‐like sepiolites are aligned in the machine direction in the solid nanocomposites. Regarding the cellular materials, the addition of sepiolites allows one to obtain anisotropic nanocellular polymers with cell sizes of 150 to 420 nm and cell nucleation densities of 1013–1014 nuclei cm−3 and presenting anisotropy ratios ranging from 1.38 to 2.15, the extrusion direction being the direction of the anisotropy. To explain the appearance of anisotropy, a mechanism based on cell coalescence is proposed and discussed. In addition, it is shown that it is possible to control the anisotropy ratio of the PMMA/sepiolite nanocellular polymers by changing the amount of well‐dispersed sepiolites in the solid nanocomposites

    Composite nature of fresh skin revealed during compression

    Get PDF
    Biological systems are subjected to moderate-to-high strain rates in blast-type traumatic injuries. An improved understanding of the responses of cells and tissues to extreme mechanical stresses could improve mitigation and post-injury treatment strategies. A key aim of this research is to create biologically meaningful injury models of soft tissues. Here the authors examine the material and cellular properties of freshly harvested porcine skin in compression. The data presented suggest that fresh skin differentially responds low to moderate strain rates as a composite rather than that of a homogeneous polymer. The implications of this work are discussed in terms of creating improved analytical models to describe the material properties of fresh skin. The Centre for Blast Injury Studies acknowledges The Royal British Legion for its support, as well as Imperial College London. The Institute of Shock Physics acknowledges the support of the Atomic Weapon Establishment, Aldermaston, UK and Imperial College London.This is the accepted manuscript. The final version is available at http://www.icevirtuallibrary.com/content/article/10.1680/bbn.14.00028

    Long-term Outcomes of Small Pigmented Choroidal Melanoma Treated with Primary Photodynamic Therapy

    Get PDF
    PURPOSE: To report the long-term outcomes of patients with small, pigmented posteriorly located choroidal melanoma undergoing primary treatment using photodynamic therapy (PDT) with verteporfin at the London Ocular Oncology Service. DESIGN: Retrospective interventional consecutive case series SUBJECTS: All patients undergoing primary treatment using PDT with verteporfin from April 2014 and December 2015 and followed until December 2019. METHODS: This is a long-term follow up study of the same cohort of patients previously reported by our group in 2017 and 2018. MAIN OUTCOME MEASURE: Local tumor control, visual outcomes and metastasis-free survival. RESULTS: Twenty-six patients were included with a mean (± SD) age and tumour thickness of 62 ± 14 years and 1.3 ± 0.5 mm, respectively. Tumours were posteriorly located (mean distance to optic nerve and fovea = 2.0 ± 2.2 and 1.6 ± 1.5 mm, respectively) and the majority were fully pigmented (73%). Overall, patients were followed for a median [IQR, range] of 49.5 [15.3, 7.0 - 66.0] months from first PDT to last follow up. Over the course of this study, 14/26 (54%) have developed a local recurrence at a median of 20.0 months [20.5, 4.7 - 60.9 months]. The most common pattern of recurrence was an isolated increase in basal dimensions (9/14; 64%). Median [IQR] final LogMAR visual acuity of the whole cohort was 0.2 [0.5]. The only statistically significant difference in baseline and outcome characteristics between treatment failures and non-failures was distance to fovea (median [IQR]: 0.5 [1.3] versus 2.5 [2.8]; P = 0.002) and final LogMAR visual acuity (median [IQR]: 0.50 [0.80] versus 0.00 [0.14]; P-value = 0.002), respectively. CONCLUSIONS: While treatment of small pigmented posterior choroidal melanoma with PDT effectively preserves visual acuity, five-year treatment-success calculated by Kaplan-Meier analysis was only 38.4%. Recurrences after PDT tend to occur along the tumor edges, often with minimal increase in thickness. Given the substantial risk of treatment failure, primary PDT with vertepofrin is recommended in exceptional cases of choroidal melanoma, where other treatments with greater tumor control are not a feasible option

    Kinesin expands and stabilizes the GDP-microtubule lattice

    Get PDF
    Kinesin-1 is a nanoscale molecular motor that walks towards the fast-growing (plus) ends of microtubules, hauling molecular cargo to specific reaction sites in cells. Kinesin-driven transport is central to the self-organization of eukaryotic cells and shows great promise as a tool for nano-engineering1. Recent work hints that kinesin may also play a role in modulating the stability of its microtubule track, both in vitro2,3 and in vivo4, but the results are conflicting5,6,7 and the mechanisms are unclear. Here, we report a new dimension to the kinesin–microtubule interaction, whereby strong-binding state (adenosine triphosphate (ATP)-bound and apo) kinesin-1 motor domains inhibit the shrinkage of guanosine diphosphate (GDP) microtubules by up to two orders of magnitude and expand their lattice spacing by ~1.6%. Our data reveal an unexpected mechanism by which the mechanochemical cycles of kinesin and tubulin interlock, and so allow motile kinesins to influence the structure, stability and mechanics of their microtubule track

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Effects of pulsed electric field on the viscoelastic properties of potato tissue

    Get PDF
    We have investigated whether transient permeabilization caused by the application of pulsed electric field would give rise to transient changes in the potato tissue viscoelastic properties. Potato tissue was subjected to nominal field strengths (E) ranging from 30 to 500 V/cm, with a single rectangular pulse of 10−5, 10−4, or 10−3 s. The changes on the viscoelastic properties of potato tissue during pulsed electric fields (PEF) were monitored through small amplitude oscillatory dynamic rheological measurements. The elastic (G′) and viscous moduli (G″) were measured every 30 s after the delivery of the pulse and the loss tangent change (tan-δ) was calculated. The results were correlated with measurements of changes on electrical resistance during the delivery of the pulse. Results show a drastic increase of tan-δ in the first 30 s after the application of the pulse, followed by a decrease 1 min after pulsation. This response is strongly influenced by pulsing conditions and is independent of the total permeabilization achieved by the pulse. Our results, supported by similar measurements on osmotically dehydrated control samples, clearly show that PEF causes a rapid change of the viscoelastic properties of the tissue that could be attributed to a partial loss in turgor pressure. This would be an expected consequence of electroporation. The recovery of tan-δ to values similar to those before pulsation strongly suggests recovery of cell membrane properties and turgor, pointing at reversible permeabilization of the cells. A slight increase of stiffness traduced by a negative change of tan-δ after application of certain PEF conditions may also give an indication of events occurring on cell wall structure due to stress responses. This study set the basis for further investigations on the complex cell stress physiology involving both cell membrane functional properties and cell wall structure that would influence tissue physical properties upon PEF application.Fundação para a Ciência e a Tecnologia (FCT

    Consideration of the bioavailability of metal/metalloid species in freshwaters: experiences regarding the implementation of biotic ligand model-based approaches in risk assessment frameworks

    Get PDF
    After the scientific development of Biotic Ligand Models (BLMs) in recent decades these models are now considered suitable for implementation in regulatory risk assessment of metals in freshwater bodies. The approach has been developed over several years and has been described in many peer-reviewed publications. The original complex BLMs have been applied in prospective risk assessment reports for metals and metal compounds and are also recommended as suitable concepts for the evaluation of monitoring data in the context of the European Water Framework Directive. Currently, several user-friendly BLM-based bioavailability software tools are available for assessing the aquatic toxicity of a limited number of metals (mainly copper, nickel, and zinc). These tools need only a basic set of water parameters as input (e.g., pH, hardness, dissolved organic matter and dissolved metal concentration). Such tools seem appropriate to foster the implementation in routine water quality assessments. This work aims to review the existing bioavailability-based regulatory approaches and the application of available BLM-based bioavailability tools for this purpose. Advantages and possible drawbacks of these tools (e.g., feasibility, boundaries of validity) are discussed, and recommendations for further implementation are given

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    corecore