225 research outputs found

    Muon capture by 3He nuclei followed by proton and deuteron production

    Full text link
    The paper describes an experiment aimed at studying muon capture by 3He{}^{3}\mathrm{He} nuclei in pure 3He{}^{3}\mathrm{He} and D2+3He\mathrm{D}_2 + {}^{3}\mathrm{He} mixtures at various densities. Energy distributions of protons and deuterons produced via μ+3Hep+n+n+νμ\mu^-+{}^{3}\mathrm{He}\to p+n+n + \nu_{\mu } and μ+3Hed+n+νμ\mu^-+{}^{3} \mathrm{He} \to d+n + \nu_{\mu} are measured for the energy intervals 104910 - 49 MeV and 133113 - 31 MeV, respectively. Muon capture rates, λcapp(ΔEp)\lambda_\mathrm{cap}^p (\Delta E_p) and λcapd(ΔEd)\lambda_\mathrm{cap}^d (\Delta E_d) are obtained using two different analysis methods. The least--squares methods gives λcapp=(36.7±1.2)s1\lambda_\mathrm{cap}^p = (36.7\pm 1.2) {s}^{- 1}, λcapd=(21.3±1.6)s1\lambda_\mathrm{cap}^d = (21.3 \pm 1.6) {s}^{- 1}. The Bayes theorem gives λcapp=(36.8±0.8)s1\lambda_\mathrm{cap}^p = (36.8 \pm 0.8) {s}^{- 1}, λcapd=(21.9±0.6)s1\lambda_\mathrm{cap}^d = (21.9 \pm 0.6) {s}^{- 1}. The experimental differential capture rates, dλcapp(Ep)/dEpd\lambda_\mathrm{cap}^p (E_p) / dE_p and dλcapd(Ed)/dEd d\lambda_\mathrm{cap}^d (E_d) / dE_d, are compared with theoretical calculations performed using the plane--wave impulse approximation (PWIA) with the realistic NN interaction Bonn B potential. Extrapolation to the full energy range yields total proton and deuteron capture rates in good agreement with former results.Comment: 17 pages, 13 figures, accepted for publication in PR

    Pleiotropic locus for emotion recognition and amygdala volume identified using univariate and bivariate linkage

    Get PDF
    Objective: The role of the amygdala in emotion recognition is well established, and amygdala volume and emotion recognition performance have each been shown separately to be highly heritable traits, but the potential role of common genetic influences on both traits has not been explored. The authors investigated the pleiotropic influences of amygdala volume and emotion recognition performance. Method: In a sample of randomly selected extended pedigrees (N=858), the authors used a combination of univariate and bivariate linkage to investigate pleiotropy between amygdala volume and emotion recognition performance and followed up with association analysis. Results: The authors found a pleiotropic region for amygdala volume and emotion recognition performance on chromosome 4q26 (LOD score=4.40). Association analysis conducted in the region underlying the bivariate linkage peak revealed a variant meeting the corrected significance level (Bonferroni-corrected p=5.01×10-5) within an intron of PDE5A (rs2622497, p=4.4×10-5) as being jointly influential on both traits. PDE5A has been implicated previously in recognition-memory deficits and is expressed in subcortical structures that are thought to underlie memory ability, including the amygdala. Conclusions: This study extends our understanding of the shared etiology between the amygdala and emotion recognition by showing that the overlap between amygdala volume and emotion recognition performance is due at least in part to common genetic influences. Moreover, this study identifies a pleiotropic locus for the two traits and an associated variant, which localizes the genetic signal even more precisely. These results, when taken in the context of previous research, highlight the potential utility of PDE5 inhibitors for ameliorating emotion recognition deficits in individuals suffering from mental or neurodegenerative illness

    The Genetic contribution to solving the cocktail-party problem

    Get PDF
    Communicating in everyday situations requires solving the cocktail-party problem, or segregating the acoustic mixture into its constituent sounds and attending to those of most interest. Humans show dramatic variation in this ability, leading some to experience real-world problems irrespective of whether they meet criteria for clinical hearing loss. Here, we estimated the genetic contribution to cocktail-party listening by measuring speech-reception thresholds (SRTs) in 425 people from large families and ranging in age from 18 to 91 years. Roughly half the variance of SRTs was explained by genes (h 2 = 0.567). The genetic correlation between SRTs and hearing thresholds (HTs) was medium (ρ G = 0.392), suggesting that the genetic factors influencing cocktail-party listening were partially distinct from those influencing sound sensitivity. Aging and socioeconomic status also strongly influenced SRTs. These findings may represent a first step toward identifying genes for hidden hearing loss, or hearing problems in people with normal HTs

    Sinus Development and Pneumatization in a Primary Ciliary Dyskinesia Cohort

    Get PDF
    Background: Primary ciliary dyskinesia (PCD) is a genetically diverse disease which causes impaired mucociliary clearance, and results in pulmonary, otologic, and rhinologic disease in affected patients. Genetic mutations in multiple genes impair the ability of patients to clear mucous from the lungs, middle ear, and sinonasal cavity and lead to chronic pulmonary and sinonasal symptoms. Methods: We identified 17 PCD patients who had available CT scans. Volumes for bilateral maxillary, sphenoid, and frontal sinuses were calculated. A control population of patients who had preoperative CT scans for endoscopic endonasal resection of skull base pathology without sinonasal cavity involvement was also identified. Results: The mean age of PCD was 33 and ranged from 13 to 54 years. Patients were age- and gender-matched to a control group that underwent resection of anterior skull-base tumors and had a mean age of 35 that ranged between 17–53 years old. The volumes for all thee sinus cavities were significantly smaller (p < 0.007) compared to the control population. The average Lund-Mackay score was 10.6 in the PCD cohort (range 6–16) in comparison to an average of 0.7 in the control cohort (range 0–2). Conclusions: Overall sinus volumes were smaller in patients with PCD compared to our control population. Future studies will be aimed at understanding defects in sinus development as a function of specific genetic mutations in PCD patients. Ultimately, a better understanding of the underlying pathophysiology of PCD will allow us to identify the optimal treatment practices for this unique patient group

    Characterization of large area avalanche photodiodes in X-ray and VUV-light detection

    Get PDF
    The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.Comment: 25 pages, 40 figures, submitted to JINS

    Characterization of large area avalanche photodiodes in X-ray and VUV-light detection

    Get PDF
    The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.Comment: 25 pages, 40 figures, submitted to JINS

    Characterization of large area avalanche photodiodes in X-ray and VUV-light detection

    Get PDF
    The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.Comment: 25 pages, 40 figures, submitted to JINS

    A human ciliopathy reveals essential functions for NEK10 in airway mucociliary clearance

    Get PDF
    Mucociliary clearance, the physiological process by which mammalian conducting airways expel pathogens and unwanted surface materials from the respiratory tract, depends on the coordinated function of multiple specialized cell types, including basal stem cells, mucus-secreting goblet cells, motile ciliated cells, cystic fibrosis transmembrane conductance regulator (CFTR)-rich ionocytes, and immune cells1,2. Bronchiectasis, a syndrome of pathological airway dilation associated with impaired mucociliary clearance, may occur sporadically or as a consequence of Mendelian inheritance, for example in cystic fibrosis, primary ciliary dyskinesia (PCD), and select immunodeficiencies3. Previous studies have identified mutations that affect ciliary structure and nucleation in PCD4, but the regulation of mucociliary transport remains incompletely understood, and therapeutic targets for its modulation are lacking. Here we identify a bronchiectasis syndrome caused by mutations that inactivate NIMA-related kinase 10 (NEK10), a protein kinase with previously unknown in vivo functions in mammals. Genetically modified primary human airway cultures establish NEK10 as a ciliated-cell-specific kinase whose activity regulates the motile ciliary proteome to promote ciliary length and mucociliary transport but which is dispensable for normal ciliary number, radial structure, and beat frequency. Together, these data identify a novel and likely targetable signaling axis that controls motile ciliary function in humans and has potential implications for other respiratory disorders that are characterized by impaired mucociliary clearance

    The Atacama Cosmology Telescope: A Catalog of >4000 Sunyaev–Zel’dovich Galaxy Clusters

    Get PDF
    We present a catalog of 4195 optically confirmed Sunyaev–Zel'dovich (SZ) selected galaxy clusters detected with signal-to-noise ratio >4 in 13,211 deg2 of sky surveyed by the Atacama Cosmology Telescope (ACT). Cluster candidates were selected by applying a multifrequency matched filter to 98 and 150 GHz maps constructed from ACT observations obtained from 2008 to 2018 and confirmed using deep, wide-area optical surveys. The clusters span the redshift range 0.04 1 clusters, and a total of 868 systems are new discoveries. Assuming an SZ signal versus mass-scaling relation calibrated from X-ray observations, the sample has a 90% completeness mass limit of M500c > 3.8 × 1014 M⊙, evaluated at z = 0.5, for clusters detected at signal-to-noise ratio >5 in maps filtered at an angular scale of 2farcm4. The survey has a large overlap with deep optical weak-lensing surveys that are being used to calibrate the SZ signal mass-scaling relation, such as the Dark Energy Survey (4566 deg2), the Hyper Suprime-Cam Subaru Strategic Program (469 deg2), and the Kilo Degree Survey (825 deg2). We highlight some noteworthy objects in the sample, including potentially projected systems, clusters with strong lensing features, clusters with active central galaxies or star formation, and systems of multiple clusters that may be physically associated. The cluster catalog will be a useful resource for future cosmological analyses and studying the evolution of the intracluster medium and galaxies in massive clusters over the past 10 Gyr
    corecore