3,168 research outputs found

    SKA Weak Lensing III: Added Value of Multi-Wavelength Synergies for the Mitigation of Systematics

    Get PDF
    In this third paper of a series on radio weak lensing for cosmology with the Square Kilometre Array, we scrutinise synergies between cosmic shear measurements in the radio and optical/near-IR bands for mitigating systematic effects. We focus on three main classes of systematics: (i) experimental systematic errors in the observed shear; (ii) signal contamination by intrinsic alignments; and (iii) systematic effects due to an incorrect modelling of non-linear scales. First, we show that a comprehensive, multi-wavelength analysis provides a self-calibration method for experimental systematic effects, only implying <50% increment on the errors on cosmological parameters. We also illustrate how the cross-correlation between radio and optical/near-IR surveys alone is able to remove residual systematics with variance as large as 0.00001, i.e. the same order of magnitude of the cosmological signal. This also opens the possibility of using such a cross-correlation as a means to detect unknown experimental systematics. Secondly, we demonstrate that, thanks to polarisation information, radio weak lensing surveys will be able to mitigate contamination by intrinsic alignments, in a way similar but fully complementary to available self-calibration methods based on position-shear correlations. Lastly, we illustrate how radio weak lensing experiments, reaching higher redshifts than those accessible to optical surveys, will probe dark energy and the growth of cosmic structures in regimes less contaminated by non-linearities in the matter perturbations. For instance, the higher-redshift bins of radio catalogues peak at z~0.8-1, whereas their optical/near-IR counterparts are limited to z<0.5-0.7. This translates into having a cosmological signal 2 to 5 times less contaminated by non-linear perturbations.Comment: 16 pages, 10 figures, 2 tables; improved discussion of experimental systematics in Sec. 2; updated to match published versio

    Estimating the weak-lensing rotation signal in radio cosmic shear surveys

    Get PDF
    Weak lensing has become an increasingly important tool in cosmology and the use of galaxy shapes to measure cosmic shear has become routine. The weak-lensing distortion tensor contains two other effects in addition to the two components of shear: the convergence and rotation. The rotation mode is not measurable using the standard cosmic shear estimators based on galaxy shapes, as there is no information on the original shapes of the images before they were lensed. Due to this, no estimator has been proposed for the rotation mode in cosmological weak-lensing surveys, and the rotation mode has never been constrained. Here, we derive an estimator for this quantity, which is based on the use of radio polarisation measurements of the intrinsic position angles of galaxies. The rotation mode can be sourced by physics beyond Λ\LambdaCDM, and also offers the chance to perform consistency checks of Λ\LambdaCDM and of weak-lensing surveys themselves. We present simulations of this estimator and show that, for the pedagogical example of cosmic string spectra, this estimator could detect a signal that is consistent with the constraints from Planck. We examine the connection between the rotation mode and the shear BB-modes and thus how this estimator could help control systematics in future radio weak-lensing surveys

    SKA Weak Lensing II: Simulated Performance and Survey Design Considerations

    Get PDF
    We construct a pipeline for simulating weak lensing cosmology surveys with the Square Kilometre Array (SKA), taking as inputs telescope sensitivity curves; correlated source flux, size and redshift distributions; a simple ionospheric model; source redshift and ellipticity measurement errors. We then use this simulation pipeline to optimise a 2-year weak lensing survey performed with the first deployment of the SKA (SKA1). Our assessments are based on the total signal-to-noise of the recovered shear power spectra, a metric that we find to correlate very well with a standard dark energy figure of merit. We first consider the choice of frequency band, trading off increases in number counts at lower frequencies against poorer resolution; our analysis strongly prefers the higher frequency Band 2 (950-1760 MHz) channel of the SKA-MID telescope to the lower frequency Band 1 (350-1050 MHz). Best results would be obtained by allowing the centre of Band 2 to shift towards lower frequency, around 1.1 GHz. We then move on to consider survey size, finding that an area of 5,000 square degrees is optimal for most SKA1 instrumental configurations. Finally, we forecast the performance of a weak lensing survey with the second deployment of the SKA. The increased survey size (3π\pi\,steradian) and sensitivity improves both the signal-to-noise and the dark energy metrics by two orders of magnitude.Comment: 15 pages, 11 figures, 1 table. Comments welcome. Updated to match published versio

    Green synthesis of vanillin: Pervaporation and dialysis for process intensification in a membrane reactor

    Get PDF
    In the present work, two different membrane processes (pervaporation and dialysis) are compared in view of their utilization in a membrane reactor, where vanillin, which is probably the most important aroma of the food industry, is synthesized in a green and sustainable way. The utilized precursor (ferulic acid, which is possibly a natural product from agricultural wastes) is partially oxidized (photocatalytically or biologically) and the product is continuously recovered from the reacting solution by the membrane process to avoid its degradation. It is observed that pervaporation is much more selective towards vanillin than dialysis, but the permeate flux of dialysis is much higher. Furthermore, dialysis can work also at lower temperatures and can be used to continuously restore the consumed substrate into the reacting mixture. A mathematical model of the integrated process (reaction combined with membrane separation) reproduces quite satisfactorily the experimental results and can be used for the analysis and the design of the process

    Weak gravitational lensing with the Square Kilometre Array

    Get PDF
    We investigate the capabilities of various stages of the SKA to perform world-leading weak gravitational lensing surveys. We outline a way forward to develop the tools needed for pursuing weak lensing in the radio band. We identify the key analysis challenges and the key pathfinder experiments that will allow us to address them in the run up to the SKA. We identify and summarize the unique and potentially very powerful aspects of radio weak lensing surveys, facilitated by the SKA, that can solve major challenges in the field of weak lensing. These include the use of polarization and rotational velocity information to control intrinsic alignments, and the new area of weak lensing using intensity mapping experiments. We show how the SKA lensing surveys will both complement and enhance corresponding efforts in the optical wavebands through cross-correlation techniques and by way of extending the reach of weak lensing to high redshift.Comment: 19 pages, 6 figures. Cosmology Chapter, Advancing Astrophysics with the SKA (AASKA14) Conference, Giardini Naxos (Italy), June 9th-13th 201

    Intravenous itraconazole for treating invasive pulmonary aspergillosis in neutropenic patients with acute lymphoblastic leukemia.

    Get PDF
    Aspergillus infection is associated with a high mortality rate in immunocompromised hosts; more effective drugs for this infection are needed. Oral itraconazole has been studied in neutropenic fungus-infected patients. Using a novel formulation (intravenous) of itraconazole, we successfully treated severe necrotizing pneumonias due to Aspergillus species occurring during a postchemotherapy prolonged aplastic phase in two patients with acute lymphoblastic leukemia

    Characterization of Large Volume 3.5 x 8 inches LaBr3:Ce Detectors

    Full text link
    The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever produced and still need to be fully characterized to determine how these detectors can be utilized and in which applications. We tested the detectors using monochromatic gamma-ray sources and in-beam reactions producing gamma rays up to 22.6 MeV; we acquired PMT signal pulses and calculated detector energy resolution and response linearity as a function of gamma-ray energy. Two different voltage dividers were coupled to the Hamamatsu R10233-100SEL PMT: the Hamamatsu E1198-26, based on straightforward resistive network design, and the LABRVD, specifically designed for our large volume LaBr3:Ce scintillation detectors, which also includes active semiconductor devices. Because of the extremely high light yield of LaBr3:Ce crystals we observed that, depending on the choice of PMT, voltage divider and applied voltage, some significant deviation from the ideally proportional response of the detector and some pulse shape deformation appear. In addition, crystal non-homogeneities and PMT gain drifts affect the (measured) energy resolution especially in case of high-energy gamma rays. We also measured the time resolution of detectors with different sizes (from 1x1 inches up to 3.5x8 inches), correlating the results with both the intrinsic properties of PMTs and GEANT simulations of the scintillation light collection process. The detector absolute full energy efficiency was measured and simulated up to gamma-rays of 30 Me

    A parametrization of the growth index of matter perturbations in various Dark Energy models and observational prospects using a Euclid-like survey

    Full text link
    We provide exact solutions to the cosmological matter perturbation equation in a homogeneous FLRW universe with a vacuum energy that can be parametrized by a constant equation of state parameter ww and a very accurate approximation for the Ansatz w(a)=w0+wa(1a)w(a)=w_0+w_a(1-a). We compute the growth index \gamma=\log f(a)/\log\Om_m(a), and its redshift dependence, using the exact and approximate solutions in terms of Legendre polynomials and show that it can be parametrized as γ(a)=γ0+γa(1a)\gamma(a)=\gamma_0+\gamma_a(1-a) in most cases. We then compare four different types of dark energy (DE) models: wΛw\LambdaCDM, DGP, f(R)f(R) and a LTB-large-void model, which have very different behaviors at z\gsim1. This allows us to study the possibility to differentiate between different DE alternatives using wide and deep surveys like Euclid, which will measure both photometric and spectroscopic redshifts for several hundreds of millions of galaxies up to redshift z2z\simeq 2. We do a Fisher matrix analysis for the prospects of differentiating among the different DE models in terms of the growth index, taken as a given function of redshift or with a principal component analysis, with a value for each redshift bin for a Euclid-like survey. We use as observables the complete and marginalized power spectrum of galaxies P(k)P(k) and the Weak Lensing (WL) power spectrum. We find that, using P(k)P(k), one can reach (2%, 5%) errors in (w0,wa)(w_0, w_a), and (4%, 12%) errors in (γ0,γa)(\gamma_0, \gamma_a), while using WL we get errors at least twice as large. These estimates allow us to differentiate easily between DGP, f(R)f(R) models and Λ\LambdaCDM, while it would be more difficult to distinguish the latter from a variable equation of state parameter or LTB models using only the growth index.}Comment: 29 pages, 7 figures, 6 table

    Identification and rejection of scattered neutrons in AGATA

    Full text link
    Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold segmented high-purity germanium crystals), placed at a distance of 50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment was to study the interaction of neutrons in the segmented high-purity germanium detectors of AGATA and to investigate the possibility to discriminate neutrons and gamma rays with the gamma-ray tracking technique. The BaF2 detectors were used for a time-of-flight measurement, which gave an independent discrimination of neutrons and gamma rays and which was used to optimise the gamma-ray tracking-based neutron rejection methods. It was found that standard gamma-ray tracking, without any additional neutron rejection features, eliminates effectively most of the interaction points due to recoiling Ge nuclei after elastic scattering of neutrons. Standard tracking rejects also a significant amount of the events due to inelastic scattering of neutrons in the germanium crystals. Further enhancements of the neutron rejection was obtained by setting conditions on the following quantities, which were evaluated for each event by the tracking algorithm: energy of the first and second interaction point, difference in the calculated incoming direction of the gamma ray, figure-of-merit value. The experimental results of tracking with neutron rejection agree rather well with Geant4 simulations

    Non-invasive diagnostic imaging of colorectal liver metastases

    Get PDF
    Colorectal cancer is one of the few malignant tumors in which synchronous or metachronous liver metastases [colorectal liver metastases (CRLMs)] may be treated with surgery. It has been demonstrated that resection of CRLMs improves the long-term prognosis. On the other hand, patients with un-resectable CRLMs may benefit from chemotherapy alone or in addition to liver- directed therapies. The choice of the most appropriate therapeutic management of CRLMs depends mostly on the diagnostic imaging. Nowadays, multiple non-invasive imaging modalities are available and those have a pivotal role in the workup of patients with CRLMs. Although extensive research has been performed with regards to the diagnostic performance of ultrasonography, computed tomography, positron emission tomography and magnetic resonance for the detection of CRLMs, the optimal imaging strategies for staging and follow up are still to be established. This largely due to the progressive technological and pharmacological advances which are constantly improving the accuracy of each imaging modality. This review describes the non-invasive imaging approaches of CRLMs reporting the technical features, the clinical indications, the advantages and the potential limitations of each modality, as well as including some information on the development of new imaging modalities, the role of new contrast media and the feasibility of using parametric image analysis as diagnostic marker of presence of CRLMs
    corecore