269 research outputs found

    Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter‐Defibrillator Systems—A Simple Issue?

    Full text link
    Background: The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter‐defibrillator (S‐ICD) system. To address the question of whether defibrillation testing in S‐ICD systems is still necessary, we analyzed the data of a large, standard‐of‐care prospective single‐center S‐ICD registry. // Methods and Results: In the present study, 102 consecutive patients received an S‐ICD for primary (n=50) or secondary prevention (n=52). Defibrillation testing was performed in all except 4 patients. In 74 (75%; 95% CI 0.66–0.83) of 98 patients, ventricular fibrillation was effectively terminated by the first programmed internal shock. In 24 (25%; 95% CI 0.22–0.44) of 98 patients, the first internal shock was ineffective and further internal or external shock deliveries were required. In these patients, programming to reversed shock polarity (n=14) or repositioning of the sensing lead (n=1) or the pulse generator (n=5) led to successful defibrillation. In 4 patients, a safety margin of <10 J was not attained. Nevertheless, in these 4 patients, ventricular arrhythmias were effectively terminated with an internal 80‐J shock. // Conclusions: Although it has been shown that defibrillation testing is not necessary in transvenous ICD systems, it seems particular important for S‐ICD systems, because in nearly 25% of the cases the primary intraoperative test was not successful. In most cases, a successful defibrillation could be achieved by changing shock polarity or by optimizing the shock vector caused by the pulse generator or lead repositioning.<br

    Dual phase patterning during a congruent grain boundary phase transition in elemental copper

    Get PDF
    The phase behavior of grain boundaries can have a strong influence on interfacial properties. Little is known about the emergence of grain boundary phases in elemental metal systems and how they transform. Here, we observe the nanoscale patterning of a grain boundary by two alternating grain boundary phases with distinct atomic structures in elemental copper by atomic resolution imaging. The same grain boundary phases are found by computational grain boundary structure search indicating a first-order transformation. Finite temperature atomistic simulations reveal a congruent, diffusionless transition between these phases under ambient pressure. The patterning of the grain boundary at room temperature is dominated by the grain boundary phase junctions separating the phase segments. Our analysis suggests that the reduced mobility of the phase junctions at low temperatures kinetically limits the transformation, but repulsive elastic interactions between them and disconnections could additionally stabilize the pattern formation

    Plastic localization phenomena in a Mn-alloyed austenitic steel

    Get PDF
    A 0.5 wt pct C, 22 wt pct Mn austenitic steel, recently proposed for fabricating automotive body structures by cold sheet forming, exhibits plastic localizations (PLs) during uniaxial tensile tests, yet showing a favorable overall strength and ductility. No localization happens during biaxial Erichsen cupping tests. Full-thickness tensile and Erichsen specimens, cut from as-produced steel sheets, were polished and tested at different strain rates. During the tensile tests, the PL phenomena consist first of macroscopic deformation bands traveling along the tensile axis, and then of a series of successive stationary deformation bands, each adjacent to the preceding ones; both types of bands involve the full specimen width and yield a macroscopically observable surface relief. No comparable surface relief was observed during the standard Erichsen tests. Because the stress state is known to influence PL phenomena, reduced-width Erichsen tests were performed on polished sheet specimens, in order to explore the transition from biaxial to uniaxial loading; surface relief lines were observed on a 20-mm-wide specimen, but not on wider ones

    Processing and mechanical properties of magnesium-lithium composites containing steel fibers

    Get PDF
    Deformation-processed metal-metal composites (DMMC) of Mg-Li alloys containing steel reinforcing fibers were prepared by infiltrating a preform of steel wool with the molten matrix. The Li content was varied to control the crystal structure of the matrix; Mg-4 wt pct Li is hexagonal close packed (hcp), while Mg-12 wt pct Li is body-centered cubic (bcc). The low carbon steel used as the reinforcing fiber is essentially bcc. The hcp/bcc and bcc/bcc composites were subsequently deformed by rolling and by extrusion/swaging and mechanically tested to relate the tensile strength of the composites to true deformation strain. The hcp/bcc composites had limited formability at temperatures up to 400 °C, while the bcc/bcc composites had excellent formability during sheet rolling at room temperature but limited formability during swaging at room temperature. The tensile strengths of the hcp/bcc composite rod and the bcc/bcc composite sheet and rod increased moderately with deformation, though less than predicted from rule-of-mixtures (ROM) calculations. This article presents the experimental data for these DMMC materials and comments on the possible effect of texture development in the matrix and fiber phases on the deformation characteristics of the composite material

    On Ti-18Si-6B and Ti-7.5Si-22.5B powder alloys prepared by high-energy ball milling and sintering

    Get PDF
    Recently, a new ternary phase was discovered in the Ti-Si-B system, located near the Ti6Si2B composition. The present study concerns the preparation of titanium alloys that contain such phase mixed with α-titanium and other intermetallic phases. High-purity powders were initially processed in a planetary ball-mill under argon atmosphere with Ti-18Si-6B and Ti-7.5Si-22.5B at. (%) initial compositions. Variation of parameters such as rotary speed, time, and ball diameters were adopted. The as-milled powders were pressureless sintered and hot pressed. Both the as-milled and sintered materials were characterized by X-ray diffraction, scanning electron microscopy and energy-dispersive spectrometry. Sintered samples have presented equilibrium structures formed mainly by the α-Ti+Ti6Si2B+Ti5Si3+TiB phases. Silicon and boron peaks disappear throughout the milling processes, as observed in the powder diffraction data. Furthermore, an iron contamination of up to 10 at. (%) is measured by X-ray spectroscopy analysis on some regions of the sintered samples. Density, hardness and tribological results for these two compositions are also presented here.Instituto Tecnologico de Aeronautica (ITA)Instituto Nacional de Pesquisas Espaciais (INPE)Universidade do Vale do Paraiba (UNIVAP)Instituto de Aeronautica e Espaco (IAE)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Instituto Tecnológico de AeronáuticaInstituto Nacional de Pesquisas EspaciaisUniversidade Estadual PaulistaUniversidade de São PauloUniversidade Estadual Paulist

    Effects of annealing treatment prior to cold rolling on delayed fracture properties in ferrite-austenite duplex lightweight steels

    Get PDF
    Tensile properties of recently developed automotive high-strength steels containing about 10 wt pct of Mn and Al are superior to other conventional steels, but the active commercialization has been postponed because they are often subjected to cracking during formation or to the delayed fracture after formation. Here, the delayed fracture behavior of a ferrite-austenite duplex lightweight steel whose microstructure was modified by a batch annealing treatment at 1023 K (750 A degrees C) prior to cold rolling was examined by HCl immersion tests of cup specimens, and was compared with that of an unmodified steel. After the batch annealing, band structures were almost decomposed as strong textures of {100}aOE (c) 011 > alpha-fibers and {111}aOE (c) 112 > gamma-fibers were considerably dissolved, while ferrite grains were refined. The steel cup specimen having this modified microstructure was not cracked when immersed in an HCl solution for 18 days, whereas the specimen having unmodified microstructure underwent the delayed fracture within 1 day. This time delayed fracture was more critically affected by difference in deformation characteristics such as martensitic transformation and deformation inhomogeneity induced from concentration of residual stress or plastic strain, rather than the difference in initial microstructures. The present work gives a promise for automotive applications requiring excellent mechanical and delayed fracture properties as well as reduced specific weight.ope

    Erratum for the Report “A precise measurement of the magnetic field in the corona of the black hole binary V404 Cygni”

    Get PDF
    In the Report “A precise measurement of the magnetic field in the corona of the black hole binary V404 Cygni,” a calculation error led to values of the magnetic field that were about 14 times too high. The mathematical expressions given in the Report were correct, but the code used to calculate the numerical values included an extraneous factor, which led to incorrect results. The magnetic fields calculated from the observations at different wavelengths were all scaled by the same factor, so after this is removed they remain consistent with each other. The corrected value of the magnetic field is lower than previously calculated, making the field in V404 Cygni even more unlike those estimated for other systems. However, the lower magnetic field is no longer consistent with the value predicted from the equipartition model. The text, materials and methods, Table S1, and Figure S3 have been updated to reflect the corrected magnetic field values and to state that the system was not in equipartition. No other results or conclusions of the study were affected. The authors thank J. Malzac (Institut de Recherche en Astrophysique et Planétologie, Université de Toulouse) for alerting them to this error
    corecore