2,447 research outputs found
Operational Planning of Active Distribution Grids under Uncertainty
Modern distribution system operators are facing constantly changing operating conditions caused by the increased penetration of intermittent renewable generators and other distributed energy resources. Under these conditions, the distribution system operators are required to operate their networks with increased uncertainty, while ensuring optimal, cost-effective, and secure operation. This paper proposes a centralized scheme for the operational planning of active distribution networks under uncertainty. A multi-period optimal power flow algorithm is used to compute optimal set-points of the controllable distributed energy resources located in the system and ensure its security. Computational tractability of the algorithm and feasibility of the resulting flows are ensured with the use of an iterative power flow method. The system uncertainty, caused by forecasting errors of renewables, is handled through the incorporation of chance constraints, which limit the probability of insecure operation. The resulting operational planning scheme is tested on a low-voltage distribution network model using real forecasting data for the renewable energy sources. We observe that the proposed method prevents insecure operation through efficient use of system controls
Pure hydrogen low-temperature plasma exposure of HOPG and graphene: Graphane formation?
Single- and multilayer graphene and highly ordered pyrolytic graphite (HOPG) were exposed to a pure hydrogen low-temperature plasma (LTP). Characterizations include various experimental techniques such as photoelectron spectroscopy, Raman spectroscopy and scanning probe microscopy. Our photoemission measurement shows that hydrogen LTP exposed HOPG has a diamond-like valence-band structure, which suggests double-sided hydrogenation. With the scanning tunneling microscopy technique, various atomic-scale charge-density patterns were observed, which may be associated with different C-H conformers. Hydrogen-LTP-exposed graphene on SiO₂ has a Raman spectrum in which the D peak to G peak ratio is over 4, associated with hydrogenation on both sides. A very low defect density was observed in the scanning probe microscopy measurements, which enables a reverse transformation to graphene. Hydrogen-LTP-exposed HOPG possesses a high thermal stability, and therefore, this transformation requires annealing at over 1000 °C
Interpretation of Core Extrusion Measurements When Tunnelling Through Squeezing Ground
Squeezing intensity in tunnelling often varies over short distances, even where there is no change in the excavation method or lithology. Reliable predictions of the ground conditions ahead of the face are thus essential to avoid project setbacks. Such predictions would enable adjustments to be made during construction to the temporary support, to the excavation diameter and also to the final lining. The assessment of the behaviour of the core ahead of the face, as observed by means of extrusion measurements, provides some indications as to the mechanical characteristics of the ground. If the ground exhibits a moderate time-dependent behaviour and the effects of the support measures are taken into account, the prediction of convergence is feasible. If the ground behaviour is pronouncedly time-dependent, however, convergence predictions become very difficult, because core extrusion is governed by the short-term characteristics of the ground, which may be different from the long-term properties that govern final convergence. The case histories of the Gotthard Base Tunnel and of the Vasto tunnel show that there is a weak correlation between the axial extrusions and the convergences of the tunnel. By means of the case histories of the Tartaiguille tunnel and Raticosa tunnel, it is shown that to identify potentially weak zones on the basis of the extrusion measurements, careful processing of the monitoring data is essential: the analysis of the data has to take account of the effects of tunnel support and time, and has to eliminate errors caused by the monitoring proces
Individualising drug dispensaries in a university hospital
BACKGROUND: In hospitals and other healthcare institutions drugs are routinely stored in designated satellite areas on the wards. Often ad hoc decisions are made by clinicians and nurses regarding drug type and quantity to be stored. As a result the number of different drugs and drug packages in storage tends to increase, which may lead to inefficient drug handling and become a potential risk factor in the medication control process. Based on an extended analysis of drug inventories on three different wards it was hypothesized that a ward-individualised formulary (WIF) can halve the number of different drugs and drug packages in a drug dispensary and hence reduce bound capital, money lost through expired drugs, and facilitate safer drug handling. The interdisciplinary intervention described here took place on three 40-bed wards in a 700-bed university hospital housing patients in general internal medicine, haematology, nephrology and oncology. METHODS: A WIF was defined by including all drugs from the hospital formulary ordered at least three times in the past six months. A pharmacist, a nurse and a clinician reviewed the inclusion list of drugs and clinicians were strongly encouraged to prescribe drugs primarily from the WIF. Drugs excluded from the WIF were removed from the drug dispensaries and the number of included drug packages stored in the remote dispensaries was reduced according to their order history. Drug inventory on the wards was monitored from February 2004 to April 2006. RESULTS: The initial drug dispensary inventories on wards A, B and C consisted of 2031, 1667 and 1536 packages with 943, 897 and 831 different drugs valued at h 83 931, h 44 590 and h 57 285. respectively. After adjusting the drug dispensaries according to the WIF drug dispensary inventories on wards A, B and C consisted of 808 (-60%), 600 (-64%) and 485 (-68%) packages with 415 (-56%), 334 (-63%) and 376 (-55%) different drugs valued euro 28 012 (-67%), euro 10 381 (-77%) an euro 17 898 (-69%). The overall reductions the number of packages, the different drugs and the drug value were comparable (<50%) and remained low during the entire observation time (A: 18 months, B: 13 months, C: 8 months). CONCLUSION: Rearranging dispensaries by individualizing the drug inventory according to the needs of the ward by introducing a WIF is a valuable means to significantly (<50%) reduce [1] the number of drug packages, [2] the number of different drugs stored and [3] the capital bound drugs. The positive effects of the WIF are supported by the interdisciplinary interaction of the different professional groups involved in the medication process. The leaner drug dispensaries offer optimal basic conditions for introducing new IT-based systems to further increase the safety of the medication process
Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds
Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined
Lab Scale Fixed-Bed Reactor for Operando X-Ray Absorption Spectroscopy for Structure Activity Studies of Supported Metal Oxide Catalysts
Lab scale fixed-bed reactor is applied for operando transmission X-ray absorption spectroscopy (XAS) for structure-activity studies of supported metal oxide catalysts under real reaction conditions. This setup includes many properties of an optimal fixed-bed reactor for operando transmission XAS studies. For instance, it is usable in a wide range of temperature (up to 1,000°C), pressure and space velocity. Besides, this operando setup can be used for transmission XAS measurements in a wide edge energy range. The potential of this reactor for operando transmission XAS is demonstrated by, as examples, the three-way catalytic performance of Pd/Al2O3/CeZrO2 and Rh/Al2O
Local spectroscopy and atomic imaging of tunneling current, forces and dissipation on graphite
Theory predicts that the currents in scanning tunneling microscopy (STM) and
the attractive forces measured in atomic force microscopy (AFM) are directly
related. Atomic images obtained in an attractive AFM mode should therefore be
redundant because they should be \emph{similar} to STM. Here, we show that
while the distance dependence of current and force is similar for graphite,
constant-height AFM- and STM images differ substantially depending on distance
and bias voltage. We perform spectroscopy of the tunneling current, the
frequency shift and the damping signal at high-symmetry lattice sites of the
graphite (0001) surface. The dissipation signal is about twice as sensitive to
distance as the frequency shift, explained by the Prandtl-Tomlinson model of
atomic friction.Comment: 4 pages, 4 figures, accepted at Physical Review Letter
The effects of acute experimental hip muscle pain on dynamic single-limb balance performance in healthy middle-aged adults
Middle-aged adults with painful hip conditions show balance impairments that are consistent with an increased risk of falls. Pathological changes at the hip, accompanied by pain, may accelerate pre-existing age-related balance deficits present in midlife. To consider the influence of pain alone, we investigated the effects of acute experimental hip muscle pain on dynamic single-limb balance in middle-aged adults. Thirty-four healthy adults aged 40–60 years formed two groups (Group-1: n\ua0=\ua016; Group-2: n\ua0=\ua018). Participants performed four tasks: Reactive Sideways Stepping (ReactSide); Star Excursion Balance Test (SEBT); Step Test; Single-Limb Squat; before and after an injection of hypertonic saline into the right gluteus medius muscle (Group-1) or ∼5\ua0min rest (Group-2). Balance measures included the range and standard deviation of centre of pressure (CoP) movement in mediolateral and anterior-posterior directions, and CoP total path velocity (ReactSide, Squat); reach distance (SEBT); and number of completed steps (Step Test). Data were assessed using three-way analysis of variance. Motor outcomes were altered during the second repetition of tasks irrespective of exposure to experimental hip muscle pain or rest, with reduced SEBT anterior reach (−1.2\ua0±\ua04.1\ua0cm, P\ua0=\ua00.027); greater step number during Step Test (1.5\ua0±\ua01.7 steps, P\ua
Distance dependence of force and dissipation in non-contact atomic force microscopy on Cu(100) and Al(111)
The dynamic characteristics of a tip oscillating in the nc-AFM mode in close
vicinity to a Cu(100)-surface are investigated by means of phase variation
experiments in the constant amplitude mode. The change of the quality factor
upon approaching the surface deduced from both frequency shift and excitation
versus phase curves yield to consistent values. The optimum phase is found to
be independent of distance. The dependence of the quality factor on distance is
related to 'true' damping, because artefacts related to phase misadjustment can
be excluded. The experimental results, as well as on-resonance measurements at
different bias voltages on an Al(111) surface, are compared to Joule
dissipation and to a model of dissipation in which long-range forces lead to
viscoelastic deformations
- …
