287 research outputs found
Educational cosmic ray experiments with Geiger counters
Experiments concerning the physics of cosmic rays offer to high-school teachers and students a relatively easy approach to the field of research in high energy physics. The detection of cosmic rays does not necessarily require the use of sophisticated equipment, and various properties of the cosmic radiation can be observed and analysed even by the use of a single Geiger counter. Nevertheless, the variety of such kind of experiments and the results obtained are limited because of the inclusive nature of these measurements. A significant improvement may be obtained when two or more Geiger counters are operated in coincidence. In this paper we discuss the potential of performing educational cosmic ray experiments with Geiger counters. In order to show also the educational value of coincidence techniques, preliminary results of cosmic ray experiments carried out by the use of a simple coincidence circuit are briefly discussed
Using Expert Models in Human Reliability Analysis - A Dependence Assessment Method Based on Fuzzy Logic
International audienceIn human reliability analysis (HRA), dependence analysis refers to assessing the influence of the failure of the operators to perform one task on the failure probabilities of subsequent tasks. A commonly used approach is the technique for human error rate prediction (THERP). The assessment of the dependence level in THERP is a highly subjective judgment based on general rules for the influence of five main factors. A frequently used alternative method extends the THERP model with decision trees. Such trees should increase the repeatability of the assessments but they simplify the relationships among the factors and the dependence level. Moreover, the basis for these simplifications and the resulting tree is difficult to trace. The aim of this work is a method for dependence assessment in HRA that captures the rules used by experts to assess dependence levels and incorporates this knowledge into an algorithm and software tool to be used by HRA analysts. A fuzzy expert system (FES) underlies the method. The method and the associated expert elicitation process are demonstrated with a working model. The expert rules are elicited systematically and converted into a traceable, explicit, and computable model. Anchor situations are provided as guidance for the HRA analyst's judgment of the input factors. The expert model and the FES-based dependence assessment method make the expert rules accessible to the analyst in a usable and repeatable way, with an explicit and traceable basis
The effect of the HDACi JAHA on DNA methylation of breast cancer cells by down-regulating DNMT1 through ERK signaling
Molecular signatures associated with the treatment of triple-negative MDA-MB231 breast cancer cells with the histone deacetylase inhibitors JAHA and SAHA
Jay Amin Hydroxamic Acid (JAHA; N8-ferrocenylN1-hydroxy-octanediamide) is a ferrocene-containing analogue of the histone deacetylase inhibitor (HDACi) suberoylanilide hydroxamic acid (SAHA). JAHA’s cytotoxic activity on MDA-MB231 triple negative breast cancer (TNBC) cells at 72 h has been previously demonstrated with an IC50 of 8.45 M. JAHA’s lethal effect was found linked to perturbations of cell cycle, mitochondrial activity, signal transduction and autophagy mechanisms. In order to glean novel insights on how MDA-MB231 breast cancer cells respond to the cytotoxic effect induced by JAHA, and to compare the biological effect with the related compound SAHA, we have employed a combination of differential display-PCR, proteome analysis and COMET assay techniques and shown some differences in the molecular signature profiles induced by exposure to either HDACis. In particular, in contrast to the more numerous and diversified changes induced by SAHA, JAHA has shown a more selective impact on expression of molecular signatures involved in anti-oxidant activity and DNA repair. Besides expanding the biological knowledge of the effect exerted by the modifications in compound structures on cell phenotype, the molecular elements put in evidence in our study may provide promising targets for therapeutic interventions on TNBCs
Beam Test Performance and Simulation of Prototypes for the ALICE Silicon Pixel Detector
The silicon pixel detector (SPD) of the ALICE experiment in preparation at
the Large Hadron Collider (LHC) at CERN is designed to provide the precise
vertex reconstruction needed for measuring heavy flavor production in heavy ion
collisions at very high energies and high multiplicity. The SPD forms the
innermost part of the Inner Tracking System (ITS) which also includes silicon
drift and silicon strip detectors. Single assembly prototypes of the ALICE SPD
have been tested at the CERN SPS using high energy proton/pion beams in 2002
and 2003. We report on the experimental determination of the spatial precision.
We also report on the first combined beam test with prototypes of the other ITS
silicon detector technologies at the CERN SPS in November 2004. The issue of
SPD simulation is briefly discussed.Comment: 4 pages, 5 figures, prepared for proceedings of 7th International
Position Sensitive Detectors Conference, Liverpool, Sept. 200
Performance of prototypes for the ALICE electromagnetic calorimeter
The performance of prototypes for the ALICE electromagnetic sampling
calorimeter has been studied in test beam measurements at FNAL and CERN. A
array of final design modules showed an energy resolution of about
11% / 1.7 % with a uniformity of the response
to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV.
The electromagnetic shower position resolution was found to be described by 1.5
mm 5.3 mm /. For an electron identification
efficiency of 90% a hadron rejection factor of was obtained.Comment: 10 pages, 10 figure
Performance of ALICE pixel prototypes in high energy beams
The two innermost layers of the ALICE inner tracking system are instrumented
with silicon pixel detectors. Single chip assembly prototypes of the ALICE
pixels have been tested in high energy particle beams at the CERN SPS.
Detection efficiency and spatial precision have been studied as a function of
the threshold and the track incidence angle. The experimental method, data
analysis and main results are presented.Comment: 10 pages, 9 figures, contribution to PIX2005 Workshop, Bonn
(Germany), 5-8 September 200
International Veterinary Epilepsy Task Force Consensus Proposal: Outcome of therapeutic interventions in canine and feline epilepsy
Common criteria for the diagnosis of drug resistance and the assessment of outcome are needed urgently as a prerequisite for standardized evaluation and reporting of individual therapeutic responses in canine epilepsy. Thus, we provide a proposal for the definition of drug resistance and partial therapeutic success in canine patients with epilepsy. This consensus statement also suggests a list of factors and aspects of outcome, which should be considered in addition to the impact on seizures. Moreover, these expert recommendations discuss criteria which determine the validity and informative value of a therapeutic trial in an individual patient and also suggest the application of individual outcome criteria. Agreement on common guidelines does not only render a basis for future optimization of individual patient management, but is also a presupposition for the design and implementation of clinical studies with highly standardized inclusion and exclusion criteria. Respective standardization will improve the comparability of findings from different studies and renders an improved basis for multicenter studies. Therefore, this proposal provides an in-depth discussion of the implications of outcome criteria for clinical studies. In particular ethical aspects and the different options for study design and application of individual patient-centered outcome criteria are considered
A variant of green fluorescent protein exclusively deposited to active intracellular inclusion bodies
Background: Inclusion bodies (IBs) were generally considered to be inactive protein deposits and did not hold any attractive values in biotechnological applications. Recently, some IBs of recombinant proteins were confirmed to show their functional properties such as enzyme activities, fluorescence, etc. Such biologically active IBs are not commonly formed, but they have great potentials in the fields of biocatalysis, material science and nanotechnology. Results: In this study, we characterized the IBs of DL4, a deletion variant of green fluorescent protein which forms active intracellular aggregates. The DL4 proteins expressed in Escherichia coli were exclusively deposited to IBs, and the IBs were estimated to be mostly composed of active proteins. The spectral properties and quantum yield of the DL4 variant in the active IBs were almost same with those of its native protein. Refolding and stability studies revealed that the deletion mutation in DL4 didn't affect the folding efficiency of the protein, but destabilized its structure. Analyses specific for amyloid-like structures informed that the inner architecture of DL4 IBs might be amorphous rather than well-organized. The diameter of fluorescent DL4 IBs could be decreased up to 100-200 nm by reducing the expression time of the protein in vivo. Conclusions: To our knowledge, DL4 is the first GFP variant that folds correctly but aggregates exclusively in vivo without any self-aggregating/assembling tags. The fluorescent DL4 IBs have potentials to be used as fluorescent biomaterials. This study also suggests that biologically active IBs can be achieved through engineering a target protein itself.open0
The ALICE Silicon Pixel Detector: readiness for the first proton beam
The Silicon Pixel Detector (SPD) is the innermost element of the ALICE Inner Tracking
System (ITS). The SPD consists of two barrel layers of hybrid silicon pixels surrounding the
beam pipe with a total of 48 10^7 pixel cells. The SPD features a very low material budget, a 99.9%
efficient bidimensional digital response, a 12 micron spatial precision in the bending plane (rf ) and a
prompt signal as input to the L0 trigger. The SPD commissioning in the ALICE experimental area
is well advanced and it includes calibration runs with internal pulse and cosmic ray runs. In this
contribution the commissioning of the SPD is reviewed and the first results from runs with cosmic
rays and circulating proton beams are presented
- …
