445 research outputs found
Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron
and the number of pixels is large (above 1000) it is virtually impossible to
use the conventional PCB read-out approach to bring the signal charge from the
individual pixel to the external electronics chain. For this reason a custom
CMOS array of 2101 active pixels with 80 micron pitch, directly used as the
charge collecting anode of a GEM amplifying structure, has been developed and
built. Each charge collecting pad, hexagonally shaped, realized using the top
metal layer of a deep submicron VLSI technology is individually connected to a
full electronics chain (pre-amplifier, shaping-amplifier, sample and hold,
multiplexer) which is built immediately below it by using the remaining five
active layers. The GEM and the drift electrode window are assembled directly
over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern
Gas Detector. With this approach, for the first time, gas detectors have
reached the level of integration and resolution typical of solid state pixel
detectors. Results from the first tests of this new read-out concept are
presented. An Astronomical X-Ray Polarimetry application is also discussed.Comment: 11 pages, 14 figures, presented at the Xth Vienna Conference on
Instrumentation (Vienna, February 16-21 2004). For a higher resolution paper
contact [email protected]
Single-shot X-ray phase-contrast computed tomography with non-microfocal laboratory sources
We present a method that enables performing x-ray phase-contrast imaging (XPCI) computed tomography with a laboratory setup using a single image per projection angle, eliminating the need to move optical elements during acquisition. Theoretical derivation of the method is presented, and its validity conditions are provided. The object is assumed to be quasihomogeneous, i.e., to feature a ratio between the refractive index and the linear attenuation coefficient that is approximately constant across the field of view. The method is experimentally demonstrated on a plastics phantom and on biological samples using a continuous rotation acquisition scheme achieving scan times of a few minutes. Moreover, we show that such acquisition times can be further reduced with the use of a high-efficiency photon-counting detector. Thanks to its ability to substantially simplify the image-acquisition procedure and greatly reduce collection times, we believe this method represents a very important step towards the application of XPCI to real-world problems
Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether
The Gas Pixel Detector belongs to the very limited class of gas detectors
optimized for the measurement of X-ray polarization in the emission of
astrophysical sources. The choice of the mixture in which X-ray photons are
absorbed and photoelectrons propagate, deeply affects both the energy range of
the instrument and its performance in terms of gain, track dimension and
ultimately, polarimetric sensitivity. Here we present the characterization of
the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME)
at 0.79 atm, selected among other mixtures for the very low diffusion
coefficient. Almost completely polarized and monochromatic photons were
produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg
diffraction at nearly 45 degrees. For the first time ever, we measured the
modulation factor and the spectral capabilities of the instrument at energies
as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV.
These measurements cover almost completely the energy range of the instrument
and allows to compare the sensitivity achieved with that of the standard
mixture, composed of helium and DME.Comment: 20 pages, 11 figures, 5 tables. Accepted for publication by NIM
Acute mammary and liver transcriptome responses after an intramammary Escherichia coli lipopolysaccharide challenge in postpartal dairy cows
The study investigated the effect of an intramammary lipopolysaccharide (LPS) challenge on the bovine mammary and liver transcriptome and its consequences on metabolic biomarkers and liver tissue composition. At 7 days of lactation, 7 cows served as controls (CTR) and 7 cows (LPS) received an intramammary Escherichia coli LPS challenge. The mammary and liver tissues for transcriptomic profiling were biopsied at 2.5 h from challenge. Liver composition was evaluated at 2.5 h and 7 days after challenge, and blood biomarkers were analyzed at 2, 3, 7 and 14 days from challenge. In mammary tissue, the LPS challenge resulted in 189 differentially expressed genes (DEG), with 20 down-regulated and 169 up-regulated. In liver tissue, there were 107 DEG in LPS compared with CTR with 42 down-regulated and 65 up-regulated. In mammary, bioinformatics analysis highlighted that LPS led to activation of NOD-like receptor signaling, Toll-like receptor signaling, RIG-I-like receptor signaling and apoptosis pathways. In liver, LPS resulted in an overall inhibition of fatty acid elongation in mitochondria and activation of the p53 signaling pathway. The LPS challenge induced changes in liver lipid composition, a systemic inflammation (rise of blood ceruloplasmin and bilirubin), and an increase in body fat mobilization. The data suggest that cells within the inflamed mammary gland respond by activating mechanisms of pathogen recognition. However, in the liver the response likely depends on mediators originating from the udder that affect liver functionality and specifically fatty acid metabolism (b-oxidation, ketogenesis, and lipoprotein synthesis).Fil: Minuti, Andrea. Universita Cattolica del Sacro Cuore; ItaliaFil: Zhou, Zheng. University Of Illinois At Urbana; Estados UnidosFil: Graugnard, Daniel E. University Of Illinois At Urbana; Estados UnidosFil: Rodriguez Zas, Sandra L.. University Of Illinois At Urbana; Estados UnidosFil: Palladino, Rafael Alejandro. Universidad de Buenos Aires. Facultad de Agronomia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Cardoso, Felipe C.. University Of Illinois At Urbana; Estados UnidosFil: Trevisi, Erminio. Universita Cattolica del Sacro Cuore; ItaliaFil: Loor, Juan J. University Of Illinois At Urbana; Estados Unido
Low energy polarization sensitivity of the Gas Pixel Detector
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been
proposed to be included in many upcoming space missions to fill the gap of
about 30 years from the first (and to date only) positive measurement of
polarized X-ray emission from an astrophysical source. The estimated
sensitivity of the current prototype peaks at an energy of about 3 keV, but the
lack of readily available polarized sources in this energy range has prevented
the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector
polarimetric sensitivity at energies of a few keV and the new, light, compact
and transportable polarized source that was devised and built to this aim.
Polarized photons are produced, from unpolarized radiation generated with an
X-ray tube, by means of Bragg diffraction at nearly 45 degrees.
The employment of mosaic graphite and flat aluminum crystals allow the
production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from
the diffraction of unpolarized continuum or line emission. The measured
modulation factor of the Gas Pixel Detector at these energies is in good
agreement with the estimates derived from a Monte Carlo software, which was up
to now employed for driving the development of the instrument and for
estimating its low energy sensitivity. In this paper we present the excellent
polarimetric performance of the Gas Pixel Detector at energies where the peak
sensitivity is expected. These measurements not only support our previous
claims of high sensitivity but confirm the feasibility of astrophysical X-ray
photoelectric polarimetry.Comment: 15 pages, 12 figures. Accepted for publication in NIM
The imaging properties of the Gas Pixel Detector as a focal plane polarimeter
X-rays are particularly suited to probe the physics of extreme objects.
However, despite the enormous improvements of X-ray Astronomy in imaging,
spectroscopy and timing, polarimetry remains largely unexplored. We propose the
photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate
to fill the gap of more than thirty years of lack of measurements. The GPD, in
the focus of a telescope, will increase the sensitivity of orders of magnitude.
Moreover, since it can measure the energy, the position, the arrival time and
the polarization angle of every single photon, allows to perform polarimetry of
subsets of data singled out from the spectrum, the light curve or the image of
source. The GPD has an intrinsic very fine imaging capability and in this work
we report on the calibration campaign carried out in 2012 at the PANTER X-ray
test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of
Garching (Germany) in which, for the first time, we coupled it to a JET-X
optics module with a focal length of 3.5 m and an angular resolution of 18
arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray
Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small
mission. We derived the imaging and polarimetric performance for extended
sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the
XIPE configuration, discussing also possible improvements by coupling the
detector with advanced optics, having finer angular resolution and larger
effective area, to study with more details extended objects.Comment: Accepted for publication in The Astrophysical Journal Supplemen
INFN Camera demonstrator for the Cherenkov Telescope Array
The Cherenkov Telescope Array is a world-wide project for a new generation of
ground-based Cherenkov telescopes of the Imaging class with the aim of
exploring the highest energy region of the electromagnetic spectrum. With two
planned arrays, one for each hemisphere, it will guarantee a good sky coverage
in the energy range from a few tens of GeV to hundreds of TeV, with improved
angular resolution and a sensitivity in the TeV energy region better by one
order of magnitude than the currently operating arrays. In order to cover this
wide energy range, three different telescope types are envisaged, with
different mirror sizes and focal plane features. In particular, for the highest
energies a possible design is a dual-mirror Schwarzschild-Couder optical
scheme, with a compact focal plane. A silicon photomultiplier (SiPM) based
camera is being proposed as a solution to match the dimensions of the pixel
(angular size of ~ 0.17 degrees). INFN is developing a camera demonstrator made
by 9 Photo Sensor Modules (PSMs, 64 pixels each, with total coverage 1/4 of the
focal plane) equipped with FBK (Fondazione Bruno Kessler, Italy) Near
UltraViolet High Fill factor SiPMs and Front-End Electronics (FEE) based on a
Target 7 ASIC, a 16 channels fast sampler (up to 2GS/s) with deep buffer,
self-trigger and on-demand digitization capabilities specifically developed for
this purpose. The pixel dimensions of mm lead to a very compact
design with challenging problems of thermal dissipation. A modular structure,
made by copper frames hosting one PSM and the corresponding FEE, has been
conceived, with a water cooling system to keep the required working
temperature. The actual design, the adopted technical solutions and the
achieved results for this demonstrator are presented and discussed.Comment: In Proceedings of the 34th International Cosmic Ray Conference
(ICRC2015), The Hague, The Netherlands. All CTA contributions at
arXiv:1508.0589
XIPE: the X-ray Imaging Polarimetry Explorer
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and
temporal variability measurements and to imaging, allows a wealth of physical
phenomena in astrophysics to be studied. X-ray polarimetry investigates the
acceleration process, for example, including those typical of magnetic
reconnection in solar flares, but also emission in the strong magnetic fields
of neutron stars and white dwarfs. It detects scattering in asymmetric
structures such as accretion disks and columns, and in the so-called molecular
torus and ionization cones. In addition, it allows fundamental physics in
regimes of gravity and of magnetic field intensity not accessible to
experiments on the Earth to be probed. Finally, models that describe
fundamental interactions (e.g. quantum gravity and the extension of the
Standard Model) can be tested. We describe in this paper the X-ray Imaging
Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a
small mission with a launch in 2017 but not selected. XIPE is composed of two
out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD)
filled with a He-DME mixture at their focus and two additional GPDs filled with
pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 %
at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half
Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X
optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with
Malindi as down-link station and of a Mission Operation Center (MOC) at INPE
(Brazil).Comment: 49 pages, 14 figures, 6 tables. Paper published in Experimental
Astronomy http://link.springer.com/journal/1068
Fermi LAT observations of cosmic-ray electrons from 7 GeV to 1 TeV
We present the results of our analysis of cosmic-ray electrons using about 8
million electron candidates detected in the first 12 months on-orbit by the
Fermi Large Area Telescope. This work extends our previously-published
cosmic-ray electron spectrum down to 7 GeV, giving a spectral range of
approximately 2.5 decades up to 1 TeV. We describe in detail the analysis and
its validation using beam-test and on-orbit data. In addition, we describe the
spectrum measured via a subset of events selected for the best energy
resolution as a cross-check on the measurement using the full event sample. Our
electron spectrum can be described with a power law with no prominent spectral features within systematic uncertainties.
Within the limits of our uncertainties, we can accommodate a slight spectral
hardening at around 100 GeV and a slight softening above 500 GeV.Comment: 20 pages, 23 figures, 2 tables, published in Physical Review D 82,
092004 (2010) - contact authors: C. Sgro', A. Moisee
- …
