251 research outputs found
Is there a “Dark Side” to Monitoring? Board and Shareholder Monitoring Effects on M&A Performance Extremeness
Research summary: We investigate the effects of monitoring by boards of directors and institutional shareholders on merger and acquisition (M&A) performance extremeness using a sample of M&A deals from 1997 to 2006. Both governance research and legal reforms generally have espoused a “raise all boats” view of monitoring. We instead investigate whether monitoring may serve as a double-edged sword that limits CEO discretion to undertake both value-destroying M&A deals and value-creating ones. Our findings indicate that the relationship between monitoring and M&A performance is more complex than previously believed. Rather than “raising all boats” in a shift towards better M&A outcomes, monitoring instead is associated with lower M&A losses, but also with lower M&A gains
Limit on Lorentz and CPT violation of the bound Neutron Using a Free Precession 3He/129Xe co-magnetometer
We report on the search for Lorentz violating sidereal variations of the
frequency difference of co-located spin-species while the Earth and hence the
laboratory reference frame rotates with respect to a relic background field.
The co-magnetometer used is based on the detection of freely precessing nuclear
spins from polarized 3He and 129Xe gas samples using SQUIDs as low-noise
magnetic flux detectors. As result we can determine the limit for the
equatorial component of the background field interacting with the spin of the
bound neutron to be bn < 3.7 x 10^{-32} GeV (95 C.L.).Comment: 5 pages, 4 figure
Test of Lorentz Symmetry by using a 3He/129Xe Co-Magnetometer
To test Lorentz symmetry we used a 3He/129Xe co-magnetometer. We will give a
short summary of our experimental setup and the results of our latest
measurements. We obtained preliminary results for the equatorial component of
the background field interacting with the spin of the bound neutron: b_n < 3.72
x 10^(-32) GeV (95 C.L.).Comment: Presented at the Fifth Meeting on CPT and Lorentz Symmetry,
Bloomington, Indiana, June 28 - July 2, 201
An Improved Neutron Electric Dipole Moment Experiment
A new measurement of the neutron EDM, using Ramsey's method of separated
oscillatory fields, is in preparation at the new high intensity source of
ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland
(PSI). The existence of a non-zero nEDM would violate both parity and time
reversal symmetry and, given the CPT theorem, might lead to a discovery of new
CP violating mechanisms. Already the current upper limit for the nEDM
(|d_n|<2.9E-26 e.cm) constrains some extensions of the Standard Model.
The new experiment aims at a two orders of magnitude reduction of the
experimental uncertainty, to be achieved mainly by (1) the higher UCN flux
provided by the new PSI source, (2) better magnetic field control with improved
magnetometry and (3) a double chamber configuration with opposite electric
field directions.
The first stage of the experiment will use an upgrade of the RAL/Sussex/ILL
group's apparatus (which has produced the current best result) moved from
Institut Laue-Langevin to PSI. The final accuracy will be achieved in a further
step with a new spectrometer, presently in the design phase.Comment: Flavor Physics & CP Violation Conference, Taipei, 200
Quantification of the aggregation of magnetic nanoparticles with different polymeric coatings in cell culture medium
The knowledge of the physico-chemical characteristics of magnetic nanoparticles (MNPs) is essential to enhance the efficacy of MNP-based therapeutic treatments (e.g. magnetic heating, magnetic drug targeting). According to the literature, the MNP uptake by cells may depend on the coating of MNPs, the surrounding medium as well as on the aggregation behaviour of the MNPs. Therefore, in this study, the aggregation behaviour of MNPs in various media was investigated. MNPs with different coatings were suspended in cell culture medium (CCM) containing fetal calf serum (FCS) and the distribution of the hydrodynamic sizes was measured by magnetorelaxometry (MRX). FCS as well as bovine serum albumin (BSA) buffer (phosphate buffered saline with 0.1% bovine serum albumin) may induce MNP aggregation. Its strength depends crucially on the type of coating. The degree of aggregation in CCM depends on its FCS content showing a clear, local maximum at FCS concentrations, where the IgG concentration (part of FCS) is of the order of the MNP number concentration. Thus, we attribute the observed aggregation behaviour to the mechanism of agglutination of MNPs by serum compartments as for example IgG. No aggregation was induced for MNPs coated with dextran, polyarabic acid or sodium phosphate, respectively, which were colloidally stable in CCM.</jats:p
Ultra-sensitive magnetometry based on free precession of nuclear spins
We discuss the design and performance of a very sensitive low-field
magnetometer based on the detection of free spin precession of gaseous, nuclear
polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The
device will be employed to control fluctuating magnetic fields and gradients in
a new experiment searching for a permanent electric dipole moment of the
neutron as well as in a new type of 3He/129Xe clock comparison experiment which
should be sensitive to a sidereal variation of the relative spin precession
frequency. Characteristic spin precession times T_2 of up to 60h could be
measured. In combination with a signal-to-noise ratio of > 5000:1, this leads
to a sensitivity level of deltaB= 1fT after an integration time of 220s and to
deltaB= 10^(-4)fT after one day. Even in that sensitivity range, the
magnetometer performance is statistically limited, and noise sources inherent
to the magnetometer are not limiting. The reason is that free precessing 3He
(129Xe) nuclear spins are almost completely decoupled from the environment.
That makes this type of magnetometer in particular attractive for precision
field measurements where a long-term stability is required
- …
