87 research outputs found
The INAF ASTRI Project in the framework of CTA
The ASTRI project aims to develop, in the framework of the Cherenkov
Telescope Array, an end-to-end prototype of the small-size telescope, devoted
to the investigation of the energy range ~ 1-100 TeV. The proposed design is
characterized by two challenging but innovative technological solutions which
will be adopted for the first time on a Cherenkov telescope: a dual-mirror
Schwarzschild-Couder configuration and a modular, light and compact camera
based on Silicon photo-multipliers. Here we describe the prototype design, the
expected performance and the possibility to realize a mini array composed by a
few such telescopes, which shall be placed at the final CTA Southern Site.Comment: 4 pages, 1 figure. Proceedings of the conference "14th ICATPP
Conference on Astroparticle, Particle, Space Physics and Detectors for
Physics Applications" (Villa Olmo, Como 23-27 September 2013
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
The LFI radiometers use a pseudo-correlation design where the signal from the
sky is continuously compared with a stable reference signal, provided by a
cryogenic reference load system. The reference unit is composed by small
pyramidal horns, one for each radiometer, 22 in total, facing small absorbing
targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately
4.5 K. Horns and targets are separated by a small gap to allow thermal
decoupling. Target and horn design is optimized for each of the LFI bands,
centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the
radiometer 20K module or connected via external electro-formed bended
waveguides. The requirement of high stability of the reference signal imposed a
careful design for the radiometric and thermal properties of the loads.
Materials used for the manufacturing have been characterized for thermal, RF
and mechanical properties. We describe in this paper the design and the
performance of the reference system.Comment: This is an author-created, un-copyedited version of an article
accepted for publication in JINST. IOP Publishing Ltd is not responsible for
any errors or omissions in this version of the manuscript or any version
derived from it. The definitive publisher authenticated version is available
online at [10.1088/1748-0221/4/12/T12006]. 14 pages, 34 figure
LFI 30 and 44 GHz receivers Back-End Modules
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency
Instrument are broadband receivers (20% relative bandwidth) working at room
temperature. The signals coming from the Front End Module are amplified, band
pass filtered and finally converted to DC by a detector diode. Each receiver
has two identical branches following the differential scheme of the Planck
radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs
P-HEMT devices, microstrip filters and Schottky diode detectors. Their
manufacturing development has included elegant breadboard prototypes and
finally qualification and flight model units. Electrical, mechanical and
environmental tests were carried out for the characterization and verification
of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules
of Planck-LFI radiometers is given, with details of the tests done to determine
their electrical and environmental performances. The electrical performances of
the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth,
equivalent noise temperature, 1/f noise and linearity are presented
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and
Astrophysic
The Large-Scale Polarization Explorer (LSPE)
The LSPE is a balloon-borne mission aimed at measuring the polarization of
the Cosmic Microwave Background (CMB) at large angular scales, and in
particular to constrain the curl component of CMB polarization (B-modes)
produced by tensor perturbations generated during cosmic inflation, in the very
early universe. Its primary target is to improve the limit on the ratio of
tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7%
confidence. A second target is to produce wide maps of foreground polarization
generated in our Galaxy by synchrotron emission and interstellar dust emission.
These will be important to map Galactic magnetic fields and to study the
properties of ionized gas and of diffuse interstellar dust in our Galaxy. The
mission is optimized for large angular scales, with coarse angular resolution
(around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload
will fly in a circumpolar long duration balloon mission during the polar night.
Using the Earth as a giant solar shield, the instrument will spin in azimuth,
observing a large fraction of the northern sky. The payload will host two
instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers
will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters,
using large throughput multi-mode bolometers and rotating Half Wave Plates
(HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz.
The wide frequency coverage will allow optimal control of the polarized
foregrounds, with comparable angular resolution at all frequencies.Comment: In press. Copyright 2012 Society of Photo-Optical Instrumentation
Engineers. One print or electronic copy may be made for personal use only.
Systematic reproduction and distribution, duplication of any material in this
paper for a fee or for commercial purposes, or modification of the content of
the paper are prohibite
Boosting the performance of the ASTRI SST-2M prototype: reflective and anti-reflective coatings
ASTRI is a Flagship Project of the Italian Ministry of Education, University and Research, led by the Italian National Institute of Astrophysics, INAF. One of the main aims of the ASTRI Project is the design, construction and verification on-field of a dual mirror (2M) end-to-end prototype for the Small Size Telescope (SST) envisaged to become part of the Cherenkov Telescope Array. The ASTRI SST-2M prototype adopts the Schwarzschild-Couder design, and a camera based on SiPM (Silicon Photo Multiplier); it will be assembled at the INAF astronomical site of Serra La Nave on mount Etna (Catania, Italy) within mid 2014, and will start scientific validation phase soon after. The peculiarities of the optical design and of the SiPM bandpass pushed towards specifically optimized choices in terms of reflective coatings for both the primary and the secondary mirror. In particular, multi-layer dielectric coatings, capable of filtering out the large Night Sky Background contamination at wavelengths nm have been developed and tested, as a solution for the primary mirrors. Due to the conformation of the ASTRI SST-2M camera, a reimaging system based on thin pyramidal light guides could be optionally integrated aiming to increase the fill factor. An anti-reflective coating optimized for a wide range of incident angles faraway from normality was specifically developed to enhance the UV-optical transparency of these elements. The issues, strategy, simulations and experimental results are thoroughly presented
Planck-LFI radiometers tuning
"This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst"
This paper describes the Planck Low Frequency Instrument tuning activities
performed through the ground test campaigns, from Unit to Satellite Levels.
Tuning is key to achieve the best possible instrument performance and tuning
parameters strongly depend on thermal and electrical conditions. For this
reason tuning has been repeated several times during ground tests and it has
been repeated in flight before starting nominal operations. The paper discusses
the tuning philosophy, the activities and the obtained results, highlighting
developments and changes occurred during test campaigns. The paper concludes
with an overview of tuning performed during the satellite cryogenic test
campaign (Summer 2008) and of the plans for the just started in-flight
calibration.Comment: This is an author-created, un-copyedited version of an article
accepted for publication in JINST. IOP Publishing Ltd is not responsible for
any errors or omissions in this version of the manuscript or any version
derived from it. The definitive publisher authenticated version is available
online at http://dx.doi.org/10.1088/1748-0221/4/12/T12013
The linearity response of the Planck-LFI flight model receivers
In this paper we discuss the linearity response of the Planck-LFI receivers,
with particular reference to signal compression measured on the 30 and 44 GHz
channels. In the article we discuss the various sources of compression and
present a model that accurately describes data measured during tests performed
with individual radiomeric chains. After discussing test results we present the
best parameter set representing the receiver response and discuss the impact of
non linearity on in-flight calibration, which is shown to be negligible.Comment: this paper is part of the Prelaunch status LFI papers published on
JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst; This is an
author-created, un-copyedited version of an article accepted for publication
in JINST. IOP Publishing Ltd is not responsible for any errors or omissions
in this version of the manuscript or any version derived from it. The
definitive publisher authenticated version is available online at
10.1088/1748-0221/4/12/T12011
- …
