1,529 research outputs found
Fifteen years follow-up of photorefractive keratectomy up to 10 D of myopia: outcomes and analysis of the refractive regression
PURPOSE:
To evaluate outcomes of photorefractive keratectomy up to -10.00 D of myopia and -4.50 of astigmatism and to develop a predictive model for the refractive changes in the long term.
SETTING:
Vissum Corporation and Miguel Hernandez University (Alicante, Spain).
DESIGN:
Retrospective-prospective observational series of cases.
METHODS:
This study included 33 eyes of 33 patients aged 46.79±7.04 years (range 40-57) operated with the VISX 20/20 excimer laser with optical zones of 6 mm. No mitomycin C was used in any of these cases. The minimum follow-up was 15 years. The main outcome measures were: uncorrected and corrected distance visual acuity, manifest refraction and corneal topography. Linear regression models were developed from the observed refractive changes over time.
RESULTS:
Safety and efficacy indexes at 15 years were 1.18 and 0.83, respectively. No statistically significant differences were detected for any keratometric variable during the follow-up (p≥0.103). 15 years after the surgery 54.55% of the eyes were within ±1.00 D of spherical equivalent and 84.85% within ±2.00 D. The uncorrected distance visual acuity at 15 years was 20/25 or better in 60.6% of the eyes and 20/40 or better in 72.73% of the eyes. The correlation between the attempted and the achieved refractions was r=0.948 (p<0.001) at 1 year, and r=0.821 (p<0.001) at 15 years. No corneal ectasia was detected in any case during the follow-up.
CONCLUSIONS:
Photorefractive keratectomy is a safe refractive procedure in the long term within the range of myopia currently considered suitable for its use, although its efficacy decreases with time, especially, in high myopia. The model developed predicts a myopic regression of 2.00 D at 15 years for an ablation depth of 130 µm
Análisis preliminar del contenido estomacal del pez espada, Xiphias gladius, en el area del Caribe
An adaptive algorithm for the cornea modeling from keratometric data
In this paper we describe an adaptive and multi-scale algorithm for the parsimonious t of the corneal surface data that allows to adapt the number of functions used in the reconstruction to the conditions of each cornea. The method implements also a dynamical selection of the parameters and the management of noise. It can be used for the real-time reconstruction of both altimetric data and corneal power maps from the data collected by keratoscopes, such as the Placido rings based topographers, decisive for an early detection of corneal diseases such as keratoconus. Numerical experiments show that the algorithm exhibits a steady exponential error decay, independently of the level of aberration of the cornea. The complexity of each anisotropic gaussian basis functions in the functional representation is the same, but their parameters vary to fit the current scale. This scale is determined only by the residual errors and not by the number of the iteration. Finally, the position and clustering of their centers, as well as the size of the shape parameters, provides an additional spatial information about the regions of higher irregularity. These results are compared with the standard approximation procedures based on the Zernike polynomials expansions
Procedimiento de reconstrucción de la topografía corneal a partir de datos altímetros o de curvatura
Número de publicación: ES2392619 A1 (12.12.2012) También publicado como: ES2392619 B1 (22.10.2013) Número de Solicitud: Consulta de Expedientes OEPM (C.E.O.) P201000842(08.06.2010)Procedimiento de reconstrucción de la topografía corneal a partir de datos altimétricos o de curvatura. La invención consiste en un método de reconstrucción de la superficie de la cara anterior de la córnea, a partir de los datos medidos en un conjunto discreto de puntos por medio de un topógrafo corneal o equipo equivalente. Se trata de un procedimiento que obtiene una expresión analítica de la superficie, combinando un ajuste por polinomios de Zernike o con esfera de mejor ajuste, con una reconstrucción por funciones de base radial gaussianas. Se logra obtener una descripción detallada de la superficie corneal, permitiendo un diagnóstico más fiable de patologías, o la implementación de tratamientos customizados. Este procedimiento es fácilmente implementable en cualquier topógrafo corneal, tomógrafo de coherencia óptica, equipos de lámpara de hendidura y equivalentes, de los existentes en el mercado, como sustituto del método estándar basado en polinomios de Zernike.Universidad de Almerí
Comparative Analysis of Some Modal Reconstruction Methods of the Shape of the Cornea from Corneal Elevation Data
Purpose: A comparative study of the ability of some modal schemes to reproduce corneal shapes of varying complexity was performed, by using both standard radial polynomials and radial basis functions (RBFs). The hypothesis was that the correct approach in the case of highly irregular corneas should combine several bases.
Methods: Standard approaches of reconstruction by Zernike and other types of radial polynomials were compared with the discrete least-squares fit (LSF) by the RBF in three theoretical surfaces, synthetically generated by computer algorithms in the absence of measurement noise. For the reconstruction by polynomials, the maximal radial order 6 was chosen, which corresponds to the first 28 Zernike polynomials or the first 49 Bhatia-Wolf polynomials. The fit with the RBF was performed by using a regular grid of centers.
Results: The quality of fit was assessed by computing for each surface the mean square errors (MSEs) of the reconstruction by LSF, measured at the same nodes where the heights were collected. Another criterion of the fit quality used was the accuracy in recovery of the Zernike coefficients, especially in the case of incomplete data.
Conclusions: The Zernike (and especially, the Bhatia-Wolf) polynomials constitute a reliable reconstruction method of a nonseverely aberrated surface with a small surface regularity index (SRI). However, they fail to capture small deformations of the anterior surface of a synthetic cornea. The most promising approach is a combined one that balances the robustness of the Zernike fit with the localization of the RBF
Refractive surgical correction and treatment of keratoconus
Keratoconus is an ectatic corneal disorder that causes severe vision loss. Surgical options allow us to correct, partially or totally, the induced refractive error. Intracorneal ring segments (ICRS) implantation represents a minimally invasive surgical option that improves visual acuity, with a high success rate and a low overall complication rate. Corneal allogenic ICRS consists of ring segments derived from allogenic eye bank-processed donor corneas. Selective topography-guided transepithelial photorefractive or phototherapeutic keratectomy combined with CXL is another way in selected cases to improve spectacles corrected distance visual acuity. The microphotoablative remodeling of the central corneal profile is generally planned by optimizing the optical zones and minimizing tissue consumption. Phakic intraocular lens (PIOL) implant is considered in patients with stable disease and acceptable anatomical requirements. The two types of pIOLs, depending on their implantation inside the eye, are anterior chamber-pIOLs, which fixate to the anterior surface of the iris by using a polymethomethacrolate claw at the two haptics, and posterior chamber-pIOLs. In patients with both cataracts and keratoconus, the correct IOL power is difficult to obtain due to the irregular corneal shape and K values. Toric IOL is recommended, but carefully judging the topography and the possible need of subsequent keratoplasties
Search for squarks and gluinos with the ATLAS detector in final states with jets and missing transverse momentum using √s=8 TeV proton-proton collision data
A search for squarks and gluinos in final states containing high-p T jets, missing transverse momentum and no electrons or muons is presented. The data were recorded in 2012 by the ATLAS experiment in s√=8 TeV proton-proton collisions at the Large Hadron Collider, with a total integrated luminosity of 20.3 fb−1. Results are interpreted in a variety of simplified and specific supersymmetry-breaking models assuming that R-parity is conserved and that the lightest neutralino is the lightest supersymmetric particle. An exclusion limit at the 95% confidence level on the mass of the gluino is set at 1330 GeV for a simplified model incorporating only a gluino and the lightest neutralino. For a simplified model involving the strong production of first- and second-generation squarks, squark masses below 850 GeV (440 GeV) are excluded for a massless lightest neutralino, assuming mass degenerate (single light-flavour) squarks. In mSUGRA/CMSSM models with tan β = 30, A 0 = −2m 0 and μ > 0, squarks and gluinos of equal mass are excluded for masses below 1700 GeV. Additional limits are set for non-universal Higgs mass models with gaugino mediation and for simplified models involving the pair production of gluinos, each decaying to a top squark and a top quark, with the top squark decaying to a charm quark and a neutralino. These limits extend the region of supersymmetric parameter space excluded by previous searches with the ATLAS detector
Measurement of the production of a W boson in association with a charm quark in pp collisions at √s = 7 TeV with the ATLAS detector
The production of a W boson in association with a single charm quark is studied using 4.6 fb−1 of pp collision data at s√ = 7 TeV collected with the ATLAS detector at the Large Hadron Collider. In events in which a W boson decays to an electron or muon, the charm quark is tagged either by its semileptonic decay to a muon or by the presence of a charmed meson. The integrated and differential cross sections as a function of the pseudorapidity of the lepton from the W-boson decay are measured. Results are compared to the predictions of next-to-leading-order QCD calculations obtained from various parton distribution function parameterisations. The ratio of the strange-to-down sea-quark distributions is determined to be 0.96+0.26−0.30 at Q 2 = 1.9 GeV2, which supports the hypothesis of an SU(3)-symmetric composition of the light-quark sea. Additionally, the cross-section ratio σ(W + +c¯¯)/σ(W − + c) is compared to the predictions obtained using parton distribution function parameterisations with different assumptions about the s−s¯¯¯ quark asymmetry
- …
