129 research outputs found

    Mobile Communication Signatures of Unemployment

    Full text link
    The mapping of populations socio-economic well-being is highly constrained by the logistics of censuses and surveys. Consequently, spatially detailed changes across scales of days, weeks, or months, or even year to year, are difficult to assess; thus the speed of which policies can be designed and evaluated is limited. However, recent studies have shown the value of mobile phone data as an enabling methodology for demographic modeling and measurement. In this work, we investigate whether indicators extracted from mobile phone usage can reveal information about the socio-economical status of microregions such as districts (i.e., average spatial resolution < 2.7km). For this we examine anonymized mobile phone metadata combined with beneficiaries records from unemployment benefit program. We find that aggregated activity, social, and mobility patterns strongly correlate with unemployment. Furthermore, we construct a simple model to produce accurate reconstruction of district level unemployment from their mobile communication patterns alone. Our results suggest that reliable and cost-effective economical indicators could be built based on passively collected and anonymized mobile phone data. With similar data being collected every day by telecommunication services across the world, survey-based methods of measuring community socioeconomic status could potentially be augmented or replaced by such passive sensing methods in the future

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe

    Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data

    Get PDF
    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns

    The effect of long-term homocysteine-lowering on carotid intima-media thickness and flow-mediated vasodilation in stroke patients: a randomized controlled trial and meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Experimental and epidemiological evidence suggests that homocysteine (tHcy) may be a causal risk factor for atherosclerosis. B-vitamin supplements reduce tHcy and improve endothelial function in short term trials, but the long-term effects of the treatment on vascular structure and function are unknown.</p> <p>Methods</p> <p>We conducted a sub-study of VITATOPS, a randomised, double-blind, placebo-controlled intervention trial designed to test the efficacy of long term B-vitamin supplementation (folic acid 2 mg, vitamin B<sub>6 </sub>25 mg and vitamin B<sub>12 </sub>0.5 mg) in the prevention of vascular events in patients with a history of stroke. We measured carotid intima-medial thickness (CIMT) and flow-mediated dilation (FMD) at least two years after randomisation in 162 VITATOPS participants. We also conducted a systematic review and meta-analysis of studies designed to test the effect of B-vitamin treatment on CIMT and FMD.</p> <p>Results</p> <p>After a mean treatment period of 3.9 ± 0.9 years, the vitamin-treated group had a significantly lower mean plasma homocysteine concentration than the placebo-treated group (7.9 μmol/L, 95% CI 7.5 to 8.4 versus 11.8 μmol/L, 95% CI 10.9 to 12.8, p < 0.001). Post-treatment CIMT (0.84 ± 0.17 mm vitamins versus 0.83 ± 0.18 mm placebo, p = 0.74) and FMD (median of 4.0%, IQR 0.9 to 7.2 vitamins versus 3.0%, IQR 0.6 to 6.6 placebo, p = 0.48) did not differ significantly between groups. A meta-analysis of published randomised data, including those from the current study, suggested that B-vitamin supplements should reduce CIMT (-0.10 mm, 95% CI -0.20 to -0.01 mm) and increase FMD (1.4%, 95% CI 0.7 to 2.1%). However, the improvement in endothelial function associated with homocysteine-lowering treatment was significant in short-term studies but not in longer trials.</p> <p>Conclusion</p> <p>Although short-term treatment with B-vitamins is associated with increased FMD, long-term homocysteine-lowering did not significantly improve FMD or CIMT in people with a history of stroke.</p> <p>Trial Registration</p> <p>Clinical Trial Registration URL: <url>http://www.actr.org.au/</url></p> <p>Trial Registration number: 12605000005651</p

    Face recognition and visual search strategies in autism spectrum disorders: Amending and extending a recent review by Weigelt et al.

    Get PDF
    The purpose of this review was to build upon a recent review by Weigelt et al. which examined visual search strategies and face identification between individuals with autism spectrum disorders (ASD) and typically developing peers. Seven databases, CINAHL Plus, EMBASE, ERIC, Medline, Proquest, PsychInfo and PubMed were used to locate published scientific studies matching our inclusion criteria. A total of 28 articles not included in Weigelt et al. met criteria for inclusion into this systematic review. Of these 28 studies, 16 were available and met criteria at the time of the previous review, but were mistakenly excluded; and twelve were recently published. Weigelt et al. found quantitative, but not qualitative, differences in face identification in individuals with ASD. In contrast, the current systematic review found both qualitative and quantitative differences in face identification between individuals with and without ASD. There is a large inconsistency in findings across the eye tracking and neurobiological studies reviewed. Recommendations for future research in face recognition in ASD were discussed

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Performance of the CMS drift tube chambers with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the paper can be accessed from the link below - Copyright @ 2010 IOPStudies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    corecore