236 research outputs found

    Genetic Variants of the Renin-Angiotensin-Aldosterone System and Reverse Remodeling After Cardiac Resynchronization Therapy

    Get PDF
    Background: Reverse remodeling (RR) after cardiac resynchronization therapy (CRT) is associated with favorable clinical outcomes in heart failure (HF). The renin-angiotensin-aldosterone system (RAAS) is involved in the remodeling process. Methods and Results: We assessed the association between RR and 8 common RAAS gene variants, which were determined by TaqMan assays, in 156 outpatients with chronic HF. RR was defined as a O15% decrease in left ventricular end systolic volume (LVESV) at 9 (interquartile range 7e12) months after CRT. We matched 76 patients who did not show RR (RR) to 80 RR? control subjects by age, sex, HF etiology, New York Heart Association (NYHA) functional class and left ventricular ejection fraction (LVEF). The frequency of the minor allele of the NR3C2 gene (rs5522 C/T), encoding the mineralocorticoid receptor, was higher in RR than in RR (24/126 vs 10/150; P value after false discovery rate correction: <.0193). Conversely, LVESV decreased significantly less after CRT in carriers of the NR3C2 minor C allele (P 5 .02). After adjustment for age, sex, NYHA functional class, previous myocardial infarction, atrial fibrillation, and LVEF, RR remained independently associated with NR3C2 C allele carriage (odds ratio 3.093, 95% confidence interval 1.253e7.632). Conclusions: The association of RR after CRT with a common polymorphism in the mineralocorticoid receptor gene involved in aldosterone signaling suggests a possible role for variants in RAAS genes in progressive LV function decline, despite apparently effective CRT

    Favorable Trend of Implantable Cardioverter-Defibrillator Service Life in a Large Single-Nation Population: Insights From 10-Year Analysis of the Italian Implantable Cardioverter-Defibrillator Registry

    Get PDF
    Background: Implantable cardioverter-defibrillators (ICDs) are widely employed for the prevention of sudden cardiac death. Despite technological improvements, patients often need to undergo generator replacement, which entails the risk of periprocedural complications. Our aim was to estimate the service life of ICDs over a 10-year interval and to assess the main causes of replacement on the basis of data from the National ICD Registry of the Italian Society of Arrhythmology and Cardiac Pacing (AIAC). Methods and Results: The registry includes data from over 400 hospitals in Italy. We included all patients who underwent device replacement from calendar years 2007 to 2016. The median service life of the ICDs and its trend over the years was estimated across the 3 types of devices (single-chamber, dual-chamber, cardiac resynchronization therapy defibrillator) and the indication to implantation. The causes of replacement were also analyzed. We included 29&nbsp;158 records from 27&nbsp;676 patients (80.9% men; mean age at device replacement 65.8±12.0&nbsp;years). The median service life was 57.3 months (interquartile range 27.8&nbsp;months). Over the years, service life showed an increasing trend. The majority of patients underwent elective replacement because of battery end of life, and over the years there was a significant reduction of replacement for recalls, erosion/infections, and cardiac resynchronization therapy upgrading. Conclusions: Our data from a large single-nation population showed that the trend of ICD service life, independently from ICD type, indication, and settings, significantly improved over time. Moreover, there was a striking reduction of interventions for upgrading and infection/erosion. This favorable trend has important clinical, organizational, and financial implications

    Treatment of atrial fibrillation with a dual defibrillator in heart failure patients (TRADE HF): protocol for a randomized clinical trial.

    Get PDF
    Background: Heart failure(HF) and atrial fibrillation(AF) frequently coexist in the same patient and are associated with increased mortality and frequent hospitalizations. As the concomitance of AF and HF is often associated with a poor prognosis, the prompt treatment of AF in HF patients may significantly improve outcome.Methods/design: Recent implantable cardiac resynchronization (CRT) devices allow electrical therapies to treat AF automatically. TRADE-HF (trial registration: NCT00345592; http://www.clinicaltrials.gov) is a prospective, randomized, double arm study aimed at demonstrating the efficacy of an automatic, device-based therapy for treatment of atrial tachycardia and fibrillation(AT/AF) in patients indicated for CRT. The study compares automatic electrical therapy to a traditional more usual treatment of AT/AF: the goal is to demonstrate a reduction in a combined endpoint of unplanned hospitalizations for cardiac reasons, death from cardiovascular causes or permanent AF when using automatic atrial therapy as compared to the traditional approach involving hospitalization for symptoms and in-hospital treatment of AT/AF.Discussion: CRT pacemaker with the additional ability to convert AF as well as ventricular arrhythmias may play a simultaneous role in rhythm control and HF treatment. The value of the systematic implantation of CRT ICDs with the capacity to deliver atrial therapy in HF patients at risk of AF has not yet been explored. The TRADE-HF study will assess in CRT patients whether a strategy based on automatic management of atrial arrhythmias might be a valuable option to reduce the number of hospital admission and to reduce the progression the arrhythmia to a permanent for

    Predictive role of early recurrence of atrial fibrillation after cryoballoon ablation

    Get PDF
    Aims The aims of this study were to determine the rate and the predictors of early recurrences of atrial fibrillation (ERAF) after cryoballoon (CB) ablation and to evaluate whether ERAF correlate with the long-term outcome. Methods and results Three thousand, six hundred, and eighty-one consecutive patients (59.9 ± 10.5 years, female 26.5%, and 74.3% paroxysmal AF) were included in the analysis. Atrial fibrillation recurrence, lasting at least 30 s, was collected during and after the 3-month blanking period. Three-hundred and sixteen patients (8.6%) (Group A) had ERAF during the blanking period, and 3365 patients (Group B) had no ERAF. Persistent AF and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of ERAF. After a mean follow-up of 16.8 ± 16.4 months, 923/3681 (25%) patients had at least one AF recurrence. The observed freedom from AF recurrence, at 24-month follow-up from procedure, was 25.7% and 64.8% in Groups A and B, respectively (P &lt; 0.001). ERAF, persistent AF, and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of AF. In a propensity score matching, the logistic model showed that ERAF 1 month after ablation are the best predictor of long-term AF recurrence (P = 0.042). Conclusion In patients undergoing CB ablation for AF, ERAF are rare and are a strong predictor of AF recurrence in the follow-up, above all when occur &gt;30 days after the ablation

    The practice of deep sedation in electrophysiology and cardiac pacing laboratories: Results of an italian survey promoted by the aiac (italian association of arrhythmology and cardiac pacing)

    Get PDF
    The aim of this survey, which was open to all Italian cardiologists involved in arrhythmia, was to assess common practice regarding sedation and analgesia in interventional electrophysiology procedures in Italy. The survey consisted of 28 questions regarding the approach to sedation used for elective direct-current cardioversion (DCC), subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, atrial fibrillation (AF) ablation, ventricular tachycardia (VT) ablation, and transvenous lead extraction procedures. A total of 105 cardiologists from 92 Italian centres took part in the survey. The rate of centres where DCC, S-ICD implantation, AF ablation, VT ablation and lead extraction procedures were performed without anaesthesiologic assistance was 60.9%, 23.6%, 51.2%, 37.3%, and 66.7%, respectively. When these procedures were performed without anaesthesiologic assistance, the drugs (in addition to local anaesthetics) commonly administered were benzodiazepines (from 64.3% to 79.6%), opioids (from 74.4% to 88.1%), and general anaesthetics (from 7.1% to 30.4%). Twenty-three (21.9%) of the 105 cardiologists declared that they routinely administered propofol, without the supervision of an anaesthesiologist, in at least one of the above-mentioned procedures. In current Italian clinical practice, there is a lack of uniformity in the sedation/analgesia approach used in interventional electrophysiology procedures

    Reproducibility of acute pulmonary vein isolation guided by the ablation index.

    Get PDF
    BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times

    Antecedent administration of angiotensin-converting enzyme inhibitors or angiotensin ii receptor antagonists and survival after hospitalization for COVID-19 syndrome

    Get PDF
    Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) utilizes the angiotensin-converting enzyme-2 (ACE-2) receptor to enter human cells. Angiotensin-converting enzyme inhibitors (ACEI) and angiotensin II receptor antagonists (ARB) are associated with ACE-2 upregulation. We hypothesized that antecedent use of ACEI/ARB may be associated with mortality in coronavirus disease 2019 (COVID-19). Methods and Results We used the Coracle registry, which contains data of patients hospitalized with COVID-19 in 4 regions of Italy, and restricted analyses to those ≥50&nbsp;years of age. The primary outcome was in-hospital mortality. Among these 781 patients, 133 (17.0%) used an ARB and 171 (21.9%) used an ACEI. While neither sex nor smoking status differed by user groups, patients on ACEI/ARB were older and more likely to have hypertension, diabetes mellitus, and congestive heart failure. The overall mortality rate was 15.1% (118/781) and increased with age (PTrend&lt;0.0001). The crude odds ratios (ORs) for death for ACEI users and ARB users were 0.98, 95% CI, 0.60-1.60, P=0.9333, and 1.13, 95% CI, 0.67-1.91, P=0.6385, respectively. After adjusting for age, hypertension, diabetes mellitus, and congestive heart failure, antecedent ACEI administration was associated with reduced mortality (OR, 0.55; 95% CI, 0.31-0.98, P=0.0436); a similar, but weaker trend was observed for ARB administration (OR, 0.58; 95% CI, 0.32-1.07, P=0.0796). Conclusions In those aged ≥50&nbsp;years hospitalized with COVID-19, antecedent use of ACEI was independently associated with reduced risk of inpatient death. Our findings suggest a protective role of renin-angiotensin-aldosterone system inhibition in patients with high cardiovascular risk affected by COVID-19
    corecore