8,677 research outputs found
Quad-band internal mobile phone antenna
A novel internal, quad-band antenna placed inside a ‘foldable’ type of Mobile Phone is presented. Its structure consists of a helical and a monopole element exciting two broad frequency bands. Using a simple matching circuit the proposed antenna covers several frequency bands including the Global System for Mobile Communication (890-960 MHz), Digital Communication System (1710-1880 MHz), Personal Communication System (1850-1990 MHz) and Universal Mobile Telecommunication System (1920-2170 MHz). It achieves a Voltage Standing Wave Ratio (VSWR) of less than three across all frequency bands with total radiation efficiency of more than 50%. Its novel design and structure occupies only 1.8 cm3 of volume making this antenna very small and very suitable for internal use inside mobile terminals
Recommended from our members
Discovering qualitative empirical laws
In this paper we describe GLAUBER, an AI system that models the scientific discovery of qualitative empirical laws. We have tested the system on data from the history of early chemistry, and it has rediscovered such concepts as acids, alkalis, and salts, as well as laws relating these concepts. After discussing GLAUBER we examine the program's relation to other discovery systems, particularly methods for conceptual clustering and language acquisition
Methods of space radiation dose analysis with applications to manned space systems
The full potential of state-of-the-art space radiation dose analysis for manned missions has not been exploited. Point doses have been overemphasized, and the critical dose to the bone marrow has been only crudely approximated, despite the existence of detailed man models and computer codes for dose integration in complex geometries. The method presented makes it practical to account for the geometrical detail of the astronaut as well as the vehicle. Discussed are the major assumptions involved and the concept of applying the results of detailed proton dose analysis to the real-time interpretation of on-board dosimetric measurements
A Personalized System for Conversational Recommendations
Searching for and making decisions about information is becoming increasingly
difficult as the amount of information and number of choices increases.
Recommendation systems help users find items of interest of a particular type,
such as movies or restaurants, but are still somewhat awkward to use. Our
solution is to take advantage of the complementary strengths of personalized
recommendation systems and dialogue systems, creating personalized aides. We
present a system -- the Adaptive Place Advisor -- that treats item selection as
an interactive, conversational process, with the program inquiring about item
attributes and the user responding. Individual, long-term user preferences are
unobtrusively obtained in the course of normal recommendation dialogues and
used to direct future conversations with the same user. We present a novel user
model that influences both item search and the questions asked during a
conversation. We demonstrate the effectiveness of our system in significantly
reducing the time and number of interactions required to find a satisfactory
item, as compared to a control group of users interacting with a non-adaptive
version of the system
A study on stability analysis of atrial repolarization variability using ARX model in sinus rhythm and atrial tachycardia ECGs
© 2016 Elsevier Ireland Ltd Background The interaction between the PTa and PP interval dynamics from the surface ECG is seldom explained. Mathematical modeling of these intervals is of interest in finding the relationship between the heart rate and repolarization variability. Objective The goal of this paper is to assess the bounded input bounded output (BIBO) stability in PTa interval (PTaI) dynamics using autoregressive exogenous (ARX) model and to investigate the reason for causing instability in the atrial repolarization process. Methods Twenty-five male subjects in normal sinus rhythm (NSR) and ten male subjects experiencing atrial tachycardia (AT) were included in this study. Five minute long, modified limb lead (MLL) ECGs were recorded with an EDAN SE-1010 PC ECG system. The number of minute ECGs with unstable segments (N us ) and the frequency of premature activation (PA) (i.e. atrial activation) were counted for each ECG recording and compared between AT and NSR subjects. Results The instability in PTaI dynamics was quantified by measuring the numbers of unstable segments in ECG data for each subject. The unstable segments in the PTaI dynamics were associated with the frequency of PA. The presence of PA is not the only factor causing the instability in PTaI dynamics in NSR subjects, and it is found that the cause of instability is mainly due to the heart rate variability (HRV). C onclusion The ARX model showed better prediction of PTa interval dynamics in both groups. The frequency of PA is significantly higher in AT patients than NSR subjects. A more complex model is needed to better identify and characterize healthy heart dynamics
Nationwide forestry applications program. Renewable resources inventory project. Multiresource Inventory Methods Pilot Test (phase 1), Volume 5
Remote sensing applications in forestry. The development of an earth resources information system using aerial photographs and digital computers photographs and digital computers
Remote aerial sensing and automatic mapping for forest resources information syste
- …
