11,063 research outputs found
Packing While Traveling: Mixed Integer Programming for a Class of Nonlinear Knapsack Problems
Packing and vehicle routing problems play an important role in the area of
supply chain management. In this paper, we introduce a non-linear knapsack
problem that occurs when packing items along a fixed route and taking into
account travel time. We investigate constrained and unconstrained versions of
the problem and show that both are NP-hard. In order to solve the problems, we
provide a pre-processing scheme as well as exact and approximate mixed integer
programming (MIP) solutions. Our experimental results show the effectiveness of
the MIP solutions and in particular point out that the approximate MIP approach
often leads to near optimal results within far less computation time than the
exact approach
A new design of friction test rig and determination of friction coefficient when warm forming an aluminium alloy
To facilitate reduced fuel consumption and increase environmental friendliness, in recent years, demands for lightweight vehicles have been increasing, and interest in hot or warm forming of sheet aluminium alloys for use in vehicle body structures, has grown. For better understanding and optimisation of the forming processes, knowledge of friction coefficient between tooling and work-piece, at elevated temperature, is critical. However, because of difficulties with measurement at elevated temperature, most studies on friction are limited to room temperature. In this study, a friction rig was designed for isothermal tests at elevated temperature. The test rig enables pure sliding between pins (made of a tool steel) and a metal sheet. The friction behaviour of Forge Ease 278, a water based solid lubricant pre-applied to aluminium alloy AA5754, was investigated, under isothermal warm forming conditions, using the test rig. The effects of testing temperature, sliding speed and applied pressure on the friction coefficient were studied. It was found that Forge Ease produced a low friction coefficient of around 0.05, above room temperature and below 250 °C. The lubricant performance degrades at 350 °C and the friction coefficient increases markedly. Both sliding speed (up to 150 mm s -1 ) and applied pressure (up to 12.8 MPa) had no significant effect on friction coefficient of Forge Ease
Impact of calcium on salivary α-amylase activity, starch paste apparent viscosity and thickness perception
Thickness perception of starch-thickened products
during eating has been linked to starch viscosity and
salivary amylase activity. Calcium is an essential cofactor
for α-amylase and there is anecdotal evidence that adding
extra calcium affects amylase activity in processes like
mashing of beer. The aims of this paper were to (1) investigate the role of salivary calcium on α-amylase
activity and (2) to measure the effect of calcium concentration on apparent viscosity and thickness perception when interacting with salivary α-amylase in starch-based samples.
α-Amylase activity in saliva samples from 28 people
was assessed using a typical starch pasting cycle (up to 95 °C). The activity of the enzyme (as measured by the change in starch apparent viscosity) was maintained by the presence of calcium, probably by protecting the enzyme from heat denaturation. Enhancement of α-amylase activity by calcium at 37 °C was also observed although to a smaller extent. Sensory analysis showed a general trend of decreased
thickness perception in the presence of calcium, but the result was only significant for one pair of samples, suggesting a limited impact of calcium enhanced enzyme activity on perceived thickness
Spatiotemporal evaluation of EMEP4UK-WRF v4.3 atmospheric chemistry transport simulations of health-related metrics for NO2, O3, PM10 and PM2.5 for 2001-2010
This study was motivated by the use in air pollution epidemiology and health burden assessment of data simulated at 5 km × 5 km horizontal resolution by the EMEP4UK-WRF v4.3 atmospheric chemistry transport model. Thus the focus of the model–measurement comparison statistics presented here was on the health-relevant metrics of annual and daily means of NO2, O3, PM2. 5, and PM10 (daily maximum 8 h running mean for O3). The comparison was temporally and spatially comprehensive, covering a 10-year period (2 years for PM2. 5) and all non-roadside measurement data from the UK national reference monitor network, which applies consistent operational and QA/QC procedures for each pollutant (44, 47, 24, and 30 sites for NO2, O3, PM2. 5, and PM10, respectively). Two important statistics highlighted in the literature for evaluation of air quality model output against policy (and hence health)-relevant standards – correlation and bias – together with root mean square error, were evaluated by site type, year, month, and day-of-week. Model–measurement statistics were generally better than, or comparable to, values that allow for realistic magnitudes of measurement uncertainties. Temporal correlations of daily concentrations were good for O3, NO2, and PM2. 5 at both rural and urban background sites (median values of r across sites in the range 0.70–0.76 for O3 and NO2, and 0.65–0.69 for PM2. 5), but poorer for PM10 (0.47–0.50). Bias differed between environments, with generally less bias at rural background sites (median normalized mean bias (NMB) values for daily O3 and NO2 of 8 and 11 %, respectively). At urban background sites there was a negative model bias for NO2 (median NMB = −29 %) and PM2. 5 (−26 %) and a positive model bias for O3 (26 %). The directions of these biases are consistent with expectations of the effects of averaging primary emissions across the 5 km × 5 km model grid in urban areas, compared with monitor locations that are more influenced by these emissions (e.g. closer to traffic sources) than the grid average. The biases are also indicative of potential underestimations of primary NOx and PM emissions in the model, and, for PM, with known omissions in the model of some PM components, e.g. some components of wind-blown dust. There were instances of monthly and weekday/weekend variations in the extent of model–measurement bias. Overall, the greater uniformity in temporal correlation than in bias is strongly indicative that the main driver of model–measurement differences (aside from grid versus monitor spatial representivity) was inaccuracy of model emissions – both in annual totals and in the monthly and day-of-week temporal factors applied in the model to the totals – rather than simulation of atmospheric chemistry and transport processes. Since, in general for epidemiology, capturing correlation is more important than bias, the detailed analyses presented here support the use of data from this model framework in air pollution epidemiology
Nanoscale atomic waveguides with suspended carbon nanotubes
We propose an experimentally viable setup for the realization of
one-dimensional ultracold atom gases in a nanoscale magnetic waveguide formed
by single doubly-clamped suspended carbon nanotubes. We show that all common
decoherence and atom loss mechanisms are small guaranteeing a stable operation
of the trap. Since the extremely large current densities in carbon nanotubes
are spatially homogeneous, our proposed architecture allows to overcome the
problem of fragmentation of the atom cloud. Adding a second nanowire allows to
create a double-well potential with a moderate tunneling barrier which is
desired for tunneling and interference experiments with the advantage of
tunneling distances being in the nanometer regime.Comment: Replaced with the published version, 7 pages, 3 figure
Bridging the Mid-Infrared-to-Telecom Gap with Silicon Nanophotonic Spectral Translation
Expanding far beyond traditional applications in optical interconnects at
telecommunications wavelengths, the silicon nanophotonic integrated circuit
platform has recently proven its merits for working with mid-infrared (mid-IR)
optical signals in the 2-8 {\mu}m range. Mid-IR integrated optical systems are
capable of addressing applications including industrial process and
environmental monitoring, threat detection, medical diagnostics, and free-space
communication. Rapid progress has led to the demonstration of various silicon
components designed for the on-chip processing of mid-IR signals, including
waveguides, vertical grating couplers, microcavities, and electrooptic
modulators. Even so, a notable obstacle to the continued advancement of
chip-scale systems is imposed by the narrow-bandgap semiconductors, such as
InSb and HgCdTe, traditionally used to convert mid-IR photons to electrical
currents. The cryogenic or multi-stage thermo-electric cooling required to
suppress dark current noise, exponentially dependent upon the ratio Eg/kT, can
limit the development of small, low-power, and low-cost integrated optical
systems for the mid-IR. However, if the mid-IR optical signal could be
spectrally translated to shorter wavelengths, for example within the
near-infrared telecom band, photodetectors using wider bandgap semiconductors
such as InGaAs or Ge could be used to eliminate prohibitive cooling
requirements. Moreover, telecom band detectors typically perform with higher
detectivity and faster response times when compared with their mid-IR
counterparts. Here we address these challenges with a silicon-integrated
approach to spectral translation, by employing efficient four-wave mixing (FWM)
and large optical parametric gain in silicon nanophotonic wires
The peaked response of transpiration rate to vapour pressure deficit in field conditions can be explained by the temperature optimum of photosynthesis
Leaf transpiration rate (E) frequently shows a peaked response to increasing vapour pressure deficit (D). The mechanisms for the decrease in E at high D, known as the 'apparent feed-forward response', are strongly debated but explanations to date have exclusively focused on hydraulic processes. However, stomata also respond to signals related to photosynthesis. We investigated whether the apparent feed-forward response of E to D in the field can be explained by the response of photosynthesis to temperature (T), which normally co-varies with D in field conditions. As photosynthesis decreases with increasing T past its optimum, it may drive a decrease in stomatal conductance (gs) that is additional to the response of gs to increasing D alone. If this additional decrease is sufficiently steep and coupling between A and gs occurs, it could cause an overall decrease in E with increasing D. We tested this mechanism using a gas exchange model applied to leaf-scale and whole-tree CO2 and H2O fluxes measured on Eucalyptus saligna growing in whole-tree chambers. A peaked response of E to D was observed at both leaf and whole-tree scales. We found that this peaked response was matched by a gas exchange model only when T effects on photosynthesis were incorporated. We conclude that field-based studies of the relationship between E and D need to consider signals related to changing photosynthetic rates in addition to purely hydraulic mechanisms. © 2014 Elsevier B.V
N = 2 SCFTs: An M5-brane perspective
Inspired by the recently discovered holographic duality between N=2 SCFTs and
half-BPS M-theory backgrounds, we study probe M5-branes. Though our main focus
is supersymmetric M5-branes whose worldvolume has an AdS_n factor, we also
consider some other configurations. Of special mention is the identification of
AdS_5 and AdS_3 probes preserving supersymmetry, with only the latter
supporting a self-dual field strength.Comment: 27 page
Most vital segment barriers
We study continuous analogues of "vitality" for discrete network flows/paths,
and consider problems related to placing segment barriers that have highest
impact on a flow/path in a polygonal domain. This extends the graph-theoretic
notion of "most vital arcs" for flows/paths to geometric environments. We give
hardness results and efficient algorithms for various versions of the problem,
(almost) completely separating hard and polynomially-solvable cases
Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review
Background: Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. Methods: We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. Results: The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Conclusion: Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation
- …
