36 research outputs found

    Tetracycline Effects on Candida Albicans Virulence Factors

    Get PDF
    Object. To determine if tetracycline, previously reported to increase the probability of developing symptomatic vaginal yeast infections, has a direct effect on Candida albicans growth or induction of virulent phenotypes. Method. In vitro, clinical isolates of yeast were cultivated with sublethal concentrations of tetracycline and yeast cell counts, hyphal formation, drug efflux pump activity, biofilm production, and hemolysin production were determined by previously reported methods. Results. Tetracycline concentrations above 150 μg/mL inhibited Candida albicans, but at submicrogram/mL, a modest growth increase during the early hours of the growth curve was observed. Tetracycline did not inhibit hyphal formation at sublethal concentrations. Hypha formation appeared augmented by exposure to tetracycline in the presence of chemically defined medium and especially in the presence of human serum. Efflux pump CDR1 was upregulated and a nonsignificant trend toward increased biofilm formation was noted. Conclusion. Tetracycline appears to have a small growth enhancing effect and may influence virulence through augmentation of hypha formation, and a modest effect on drug efflux and biofilm formation, although tetracycline did not affect hemolysin. It is not clear if the magnitude of the effect is sufficient to attribute vaginitis following tetracycline treatment to direct action of tetracycline on yeast

    Ultrasound measurements of the first extensor compartment: determining the transection limits for ultra-minimally invasive release of De Quervain tenosynovitis

    No full text
    Background: De Quervain syndrome is the second most common compressive tendinopathy. Although the length of the first extensor compartment (FEC) has been studied previously, there is no documented reported comparison study of short-axis and long-axis sonographic measurements. The thread technique, or Guo Technique, has been applied to carpal tunnel syndrome, trigger finger, and superficial peroneal compressive neuropathy. To perform this procedure, it is critically important to accurately identify the boundaries for transection. Methods: Twenty-one fresh frozen cadaver upper extremities were examined under ultrasound to determine the length of the extensor retinaculum (ER) over the FEC. Using the sonographic landmarks, the ERs were measured in short axis and long axis over their proximal to distal margins and from the distal margins to the distal edges of the radial styloids. These sonographic measurements were then compared with gross anatomical measurements. Results: The short-axis sonographic measurement of the ER on average was 22.53 mm (95% confidence interval [CI] = 20.79-24.05 mm). The long-axis sonographic measurement of the ER on average was 15.65 mm (95% CI = 13.70-17.78 mm). The average length of the ER by gross anatomical dissection was 22.40 mm (95% CI = 21.15-23.51 mm). Conclusions: The short axis is not significantly different from the gross anatomical measurement; however, the long axis is significantly lower than the gross anatomical measurement. The results support the idea that the short axis is more accurate than the long axis

    Ultrasound Measurements of the First Extensor Compartment: Determining the Transection Limits for Ultra-minimally Invasive Release of De Quervain Tenosynovitis

    Full text link
    Background: De Quervain syndrome is the second most common compressive tendinopathy. Although the length of the first extensor compartment (FEC) has been studied previously, there is no documented reported comparison study of short-axis and long-axis sonographic measurements. The thread technique, or Guo Technique, has been applied to carpal tunnel syndrome, trigger finger, and superficial peroneal compressive neuropathy. To perform this procedure, it is critically important to accurately identify the boundaries for transection. Methods: Twenty-one fresh frozen cadaver upper extremities were examined under ultrasound to determine the length of the extensor retinaculum (ER) over the FEC. Using the sonographic landmarks, the ERs were measured in short axis and long axis over their proximal to distal margins and from the distal margins to the distal edges of the radial styloids. These sonographic measurements were then compared with gross anatomical measurements. Results: The short-axis sonographic measurement of the ER on average was 22.53 mm (95% confidence interval [CI] = 20.79-24.05 mm). The long-axis sonographic measurement of the ER on average was 15.65 mm (95% CI = 13.70-17.78 mm). The average length of the ER by gross anatomical dissection was 22.40 mm (95% CI = 21.15-23.51 mm). Conclusions: The short axis is not significantly different from the gross anatomical measurement; however, the long axis is significantly lower than the gross anatomical measurement. The results support the idea that the short axis is more accurate than the long axis. </jats:p

    The modified ultrasound-guided distal-to-proximal carpal tunnel injection with median nerve hydrodissection: A retrospective safety review of 827 procedures

    No full text
    Objective: The aim of this report is to describe a new ultrasound guided technique for carpal tunnel injection and median nerve hydrodissection using distal to proximal approach. Methods: From 2015 to 2019, 827 consecutive injections by distal-to-proximal approach were included using coding information to check for post-procedural skin hypopigmentation, hematoma, seroma, nerve injury, or vascular injury. Results: There were no occurrences of post-procedural skin-hypopigmentation, hematoma or seroma formation, or neurovascular injury. Conclusions: The distal approach carpal tunnel injection is a safe and effective method. It may directly inject the medication into carpal tunnel to avoid skin hypopigmentation from steroid side effect with previous report method, also it may release adhesion of median nerve with surrounding soft tissue by hydrodissection. It helps median nerve compression at outlet of carpal tunnel

    The Modified Ultrasound-Guided Distal-to-Proximal Carpal Tunnel Injection With Median Nerve Hydrodissection: A Retrospective Safety Review of 827 Procedures

    Full text link
    Objective: The aim of this report is to describe a new ultrasound guided technique for carpal tunnel injection and median nerve hydrodissection using distal to proximal approach. Methods: From 2015 to 2019, 827 consecutive injections by distal-to-proximal approach were included using coding information to check for post-procedural skin hypopigmentation, hematoma, seroma, nerve injury, or vascular injury. Results: There were no occurrences of post-procedural skin-hypopigmentation, hematoma or seroma formation, or neurovascular injury. Conclusions: The distal approach carpal tunnel injection is a safe and effective method. It may directly inject the medication into carpal tunnel to avoid skin hypopigmentation from steroid side effect with previous report method, also it may release adhesion of median nerve with surrounding soft tissue by hydrodissection. It helps median nerve compression at outlet of carpal tunnel. </jats:p

    A Cadaveric Study of the Thread Trigger Finger Release: The First Annular Pulley Transection Through Thread Transecting Technique

    Full text link
    Background: After the thread transecting technique was successfully applied for the thread carpal tunnel release, we researched using the same technique in the thread trigger finger release (TTFR). This study was designed to test the operational feasibility of the TTFR on cadavers and verify the limits of division on the first annular (A1) pulley to ensure a complete trigger finger release with minimal iatrogenic injuries. Methods: The procedure of TTFR was performed on 14 fingers and 4 thumbs of 4 unembalmed cadaveric hands. After the procedures, all fingers and thumbs were dissected and visually assessed. Results: All of the digits and thumbs demonstrated a complete A1 pulley release. There was no injury to the neurovascular bundle (radial digital nerve in case of thumb), flexor tendon, or A2 pulley for each case. Conclusions: The cadaveric study showed that the technique of TTFR was safe and effective, and the future clinical study is necessary to verify the findings of this study.</jats:p

    Percutaneous cubital tunnel release with a dissection thread: a cadaveric study

    No full text
    This cadaveric study tested the feasibility of decompressing the ulnar nerve across the elbow percutaneously with a commercially available surgical dissection thread, a guiding needle, hydrodissection and ultrasound guidance. We performed the procedure in 19 fresh-frozen cadaveric upper extremities. Subsequently, we did an anatomical dissection of the specimens to visualize the extent of ulnar nerve decompression and the extent of damage to surrounding structures. The cubital tunnel and deep across the medial elbow were completely transected leaving the ulnar nerve fully decompressed in all cases. There was no evidence of direct injury to the ulnar nerve or adjacent neurovascular structures. A prerequisite knowledge of sonographic anatomy and experience with interventional ultrasound is essential. Future clinical studies should evaluate this technique\u27s safety and efficacy compared with conventional ones

    Percutaneous cubital tunnel release with a dissection thread: a cadaveric study

    Full text link
    This cadaveric study tested the feasibility of decompressing the ulnar nerve across the elbow percutaneously with a commercially available surgical dissection thread, a guiding needle, hydrodissection and ultrasound guidance. We performed the procedure in 19 fresh-frozen cadaveric upper extremities. Subsequently, we did an anatomical dissection of the specimens to visualize the extent of ulnar nerve decompression and the extent of damage to surrounding structures. The cubital tunnel and deep across the medial elbow were completely transected leaving the ulnar nerve fully decompressed in all cases. There was no evidence of direct injury to the ulnar nerve or adjacent neurovascular structures. A prerequisite knowledge of sonographic anatomy and experience with interventional ultrasound is essential. Future clinical studies should evaluate this technique’s safety and efficacy compared with conventional ones. </jats:p
    corecore