1,005 research outputs found

    Mediterraneo:una storia incompleta

    Get PDF
    It is common opinion that Mediterranean history will always be incomplete, even though many reflexions and discussions have been made concerning what is called this “liquid womb”. In the past few years the traditional-rational interpretations that we may consider obvious has been replaced in an alternative, utilitarian, intuitive post-modern logic that has challenged consolidates approaches (Geograpfhic, historical, philosophical, political) obliging us to questions our certaintes in order to find alternatives-interpretative categories able to read the complexity, the diversità, the risks. In any case, the question of ”what the Mediterranean is” remains without any reply. It may be that what is thought of as Mediterranean might not reallty exist or has been thought of as a pluriuniverse Towards which the simbolic, the imaginary have prevailed over what is real, as if Mediterranean thought might be the thought of what is inexistent. At present Geopolitica see this region a san area of mediation of conflicts. However even with all that we have done,we have not succeeded in making the Mediterraneum a polare of a universal and collective love and peace.Geopolitics, Post-modernity thought, Mediterranean

    Reference crop evapotranspiration estimate using high-resolution meteorological network's data

    Get PDF
    Water management authorities need detailed information about each component of the hydrological balance. This document presents a method to estimate the evapotranspiration rate, initialized in order to obtain the reference crop evapotranspiration rate (<i>ET</i><sub>0</sub>). By using an Optimal Interpolation (OI) scheme, the hourly observations of several meteorological variables, measured by a high-resolution local meteorological network, are interpolated over a regular grid. The analysed meteorological fields, containing detailed meteorological information, enter a model for turbulent heat fluxes estimation based on Monin-Obukhov surface layer similarity theory. The obtained <i>ET</i><sub>0</sub> fields are then post-processed and disseminated to the users

    Anomalous Weak Values and the Violation of a Multiple-measurement Leggett-Garg Inequality

    Get PDF
    Quantum mechanics presents peculiar properties that, on the one hand, have been the subject of several theoretical and experimental studies about its very foundations and, on the other hand, provide tools for developing new technologies, the so-called quantum technologies. The nonclassicality pointed out by Leggett-Garg inequalities has represented, with Bell inequalities, one of the most investigated subject. In this letter we study the connection of Leggett-Garg inequalities with a new emerging field of quantum measurement, the weak values. In particular, we perform an experimental study of the four-time correlators Legget-Garg test, by exploiting single and sequential weak measurements performed on heralded single photons. We show violation of a four-parameters Leggett-Garg inequality in different experimental conditions, demonstrating an interesting connection between Leggett-Garg inequality violation and anomalous weak values

    Experiment Investigating the Connection between Weak Values and Contextuality

    Get PDF
    Weak value measurements have recently given rise to a large interest for both the possibility of measurement amplification and the chance of further quantum mechanics foundations investigation. In particular, a question emerged about weak values being proof of the incompatibility between Quantum Mechanics and Non-Contextual Hidden Variables Theories (NCHVT). A test to provide a conclusive answer to this question was given in [M. Pusey, Phys. Rev. Lett. 113, 200401 (2014)], where a theorem was derived showing the NCHVT incompatibility with the observation of anomalous weak values under specific conditions. In this paper we realize this proposal, clearly pointing out the strict connection between weak values and the contextual nature of Quantum Mechanics.Comment: 5 pages, 4 figure

    Enhanced single-photon time-of-flight 3D ranging

    Get PDF
    We developed a system for acquiring 3D depth-resolved maps by measuring the Time-of-Flight (TOF) of single photons. It is based on a CMOS 32 × 32 array of Single-Photon Avalanche Diodes (SPADs) and 350 ps resolution Time-to-Digital Converters (TDCs) into each pixel, able to provide photon-counting or photon-timing frames every 10 μs. We show how such a system can be used to scan large scenes in just hundreds of milliseconds. Moreover, we show how to exploit TDC unwarping and refolding for improving signal-to-noise ratio and extending the full-scale depth range. Additionally, we merged 2D and 3D information in a single image, for easing object recognition and tracking

    High linearity SPAD and TDC array for TCSPC and 3D ranging applications

    Get PDF
    An array of 32x32 Single-Photon Avalanche-Diodes (SPADs) and Time-to-Digital Converters (TDCs) has been fabricated in a 0.35 mu m automotive-certified CMOS technology. The overall dimension of the chip is 9x9 mm(2). Each pixel is able to detect photons in the 300 nm - 900 nm wavelength range with a fill-factor of 3.14% and either to count them or to time stamp their arrival time. In photon-counting mode an in-pixel 6-bit counter provides photon-number-resolved intensity movies at 100 kfps, whereas in photon-timing mode the 10-bit in-pixel TDC provides time-resolved maps (Time-Correlated Single-Photon Counting measurements) or 3D depth-resolved (through direct time-of-flight technique) images and movies, with 312 ps resolution. The photodetector is a 30 mu m diameter SPAD with low Dark Count Rate (120 cps at room temperature, 3% hot-pixels) and 55% peak Photon Detection Efficiency (PDE) at 450 nm. The TDC has a 6-bit counter and a 4-bit fine interpolator, based on a Delay Locked Loop (DLL) line, which makes the TDC insensitive to process, voltage, and temperature drifts. The implemented sliding-scale technique improves linearity, giving 2% LSB DNL and 10% LSB INL. The single-shot precision is 260 ps rms, comprising SPAD, TDC and driving board jitter. Both optical and electrical crosstalk among SPADs and TDCs are negligible. 2D fast movies and 3D reconstructions with centimeter resolution are reported

    Photon-efficient imaging with a single-photon camera

    Get PDF
    Reconstructing a scene’s 3D structure and reflectivity accurately with an active imaging system operating in low-light-level conditions has wide-ranging applications, spanning biological imaging to remote sensing. Here we propose and experimentally demonstrate a depth and reflectivity imaging system with a single-photon camera that generates high-quality images from ∼1 detected signal photon per pixel. Previous achievements of similar photon efficiency have been with conventional raster-scanning data collection using single-pixel photon counters capable of ∼10-ps time tagging. In contrast, our camera’s detector array requires highly parallelized time-to-digital conversions with photon time-tagging accuracy limited to ∼ns. Thus, we develop an array-specific algorithm that converts coarsely time-binned photon detections to highly accurate scene depth and reflectivity by exploiting both the transverse smoothness and longitudinal sparsity of natural scenes. By overcoming the coarse time resolution of the array, our framework uniquely achieves high photon efficiency in a relatively short acquisition time.National Science Foundation (U.S.) (1161413)National Science Foundation (U.S.) (1422034)Lincoln LaboratorySamsung (Firm
    corecore