3,129 research outputs found
The neurochemical basis of photic entrainment of the circadian pacemaker
Circadian rhythmicity in mammals is controlled by the action of a light-entrainable hypothalamus, in association with two cell clusters known as the supra chiasmatic nuclei (SCN). In the absence of temporal environmental clues, this pacemaker continues to measure time by an endogenous mechanism (clock), driving biochemical, physiological, and behavioral rhythms that reflect the natural period of the pacemaker oscillation. This endogenous period usually differs slightly from 24 hours (i.e., circadian). When mammals are maintained under a 24 hour light-dark (LD) cycle, the pacemaker becomes entrained such that the period of the pacemaker oscillation matches that of the LD cycle. Potentially entraining photic information is conveyed to the SCN via a direct retinal projection, the retinohypothalamic tract (RHT). RHT neurotransmission is thought to be mediated by the release of excitatory amino acids (EAA) in the SCN. In support of this hypothesis, recent experiments using nocturnal rodents have shown that EAA antagonists block the effects of light on pacemaker-driven behavioral rhythms, and attenuate light induced gene expression in SCN cells. An understanding of the neurochemical basis of the photic entrainment process would facilitate the development of pharmacological strategies for maintaining synchrony among shift workers in environments, such as the Space Station, which provide unreliable or conflicting temporal photic clues
Artificial Evolution, 5th International Conference, Evolution Artificielle, EA 200. Selected Papers
In gas laser ionization and spectroscopy experiments at the Superconducting Separator Spectrometer (S3): Conceptual studies and preliminary design
International audienceThe results of preparatory experiments and the preliminary designs of a new in-gas laser ionization and spectroscopy setup, to be coupled to the Super Separator Spectrometer S3 of SPIRAL2-GANIL, are reported. Special attention is given to the development and tests to carry out a full implementation of the in-gas jet laser spectroscopy technique. Application of this novel technique to radioactive species will allow highsensitivity and enhanced-resolution laser spectroscopy studies of ground- and excited-state properties of exotic nuclei
Carbohydrate Reserves of Perennial Grasses: Effect of Drought and Defoliation Intensity
The carbohydrate reserves of six perennial grasses were measured during exposure to drought and defoliation over spring-summer and summer-autumn seasons. Of the six species assessed, tall fescue (Festuca arundinacea) and perennial ryegrass (Lolium perenne) had the highest level of reserves while wallaby grass (Danthonia richardsonii) had the lowest levels. The results indicate that during the spring-summer period drought intensity had a greater effect on plant reserves than defoliation intensity. However, defoliation had a greater effect on reserves during the summer-autumn period. It is suggested that tiller reserves may be most affected when drought is moderate and defoliation is severe
Signature of Martensite transformation on conductivity noise in thin films of NiTi shape memory alloys
Slow time-dependent fluctuations, or noise, in the electrical resistance of
dc magnetron sputtered thin films of Nickel Titanium shape memory alloys have
been measured. Even in equilibrium, the noise was several orders of magnitude
larger than that of simple diffusive metallic films, and was found to be
non-monotonic around the martensitic transformation regime. The results are
discussed in terms of dynamics of structural defects, which also lay foundation
to a new noise-based characterization scheme of martensite transformation.Comment: 4 pages, 3 figure
Significant variability exists in preoperative planning software measures of glenoid morphology for shoulder arthroplasty
Background & Hypothesis: We sought to assess the reliability of 4 different shoulder arthroplasty 3-dimensional preoperative planning programs. Comparison was also made to manual measurements conducted by 2 fellowship-trained musculoskeletal radiologists. We hypothesized that there would be significant variation in measurements of glenoid anatomy affected by glenoid deformity.
Methods: A retrospective review of computed tomography (CT) scans of patients undergoing shoulder arthroplasty was undertaken. A total of 76 computed tomographies were analyzed for glenoid version and inclination by 4 templating software systems (VIP, Blueprint, TrueSight, ExactechGPS). Inter-rater reliability was assessed via intra-class correlation coefficient (ICC). For those shoulders with glenohumeral arthritis (58/76), ICC was also calculated when sub-grouping by modified Walch classification. Lin\u27s concordance correlation coefficient was calculated for each system with 2 musculoskeletal-trained radiologists’ measurements.
Results: Measurements of glenoid version and inclination differed between at least 2 programs by 5º-10º in 75% and 92% of glenoids respectively, and by \u3e10º in 18% and 45% respectively. ICC was excellent for version but only moderate for inclination. ICC was highest among Walch A glenoids for both version (near excellent) and inclination (good), and lowest among Walch D for version (near poor) and Walch B for inclination (moderate). When measuring version, VIP had the highest concordance with manual measurement; Blueprint had the lowest. For inclination Blueprint had the highest concordance; ExactechGPS had the lowest.
Discussion & Conclusion: Despite overall high reliability for measures of glenoid version between 4 frequently utilized shoulder arthroplasty templating softwares, this reliability is significantly affected by glenoid deformity. The programs were overall less reliable when measuring inclination, and a similar trend of decreasing reliability with increasing glenoid deformity emerged that was not statistically significant. Concordance with manual measurement is also variable. Further research is needed to understand how this variability should be accounted for during shoulder arthroplasty preoperative planning.
Level of Evidence: Level III; Retrospective Comparative Stud
- …
