426 research outputs found
Gaining comprehensive data about sexual knowledge through surveys
Background:
Delivery of sexual health services rely on rigorous facts extracted from surveys, but often those facts cannot be available due to the lack of culturally-sensitive questionnaires.
Objective:
our aim was to show the validity and reliability of the Persian version of the Acquisition of Sexual Information Test (ASIT), a measure selected due to its assemblages with Iranian culture.
Materials and Methods:
Forward-backward procedure was applied to translate the questionnaire. Cross-sectional study was carried out and psychometric properties of the Iranian version were tested in a thirty sample of reproductive-age women. Face validity was assessed by qualitative and quantitative methods. Content validity was also assessed by calculating two quantitative indicators as content validity index (CVI) and content validity ratio (CVR). Reliability was assessed by test-retest analyses.
Results:
Impact score was 1.5, the majority of participants (83.3%) stated that the overall level of questionnaire was high but some of the questions were irrelevant to sexual knowledge. Many questions (90%) gained a CVR less than 0.56, and all of them gained CVIs lower than 0.7. Correlation in test-retest reliability was 0.85
Modeling startup and shutdown transient of the microlinear piezo drive via ANSYS
The article describes the construction-design of the micro linear piezo drive intended for a peripheral cord tensioner in the reflecting surface shape regulator system for large-sized transformable spacecraft antenna reflectors. The research target -the development method of modeling startup and shutdown transient of the micro linear piezo drive. This method is based on application software package ANSYS. The method embraces a detailed description of the calculation stages to determine the operating characteristics of the designed piezo drive. Based on the numerical solutions, the time characteristics of the designed piezo drive are determined
Microlinear piezo drive experiments
The article embraces the experimental description of the micro linear piezo drive intended for the peripheral cord tensioner in the reflecting surface shape regulator system for large-sized transformable spacecraft antenna reflectors. The research target is the experimental investigation of the micro linear piezo drive to determine the stable oscillatory system operating modes which would include improved energy conversion parameters. The following points are briefly presented: test stand construction-design of the peripheral cord tensioner; the determined frequency characteristics and the identified resonant and actual frequencies of an oscillatory system under inertia load. A series of experiments has been conducted for both different preliminary voltages and inertia mass values
The antitumor efficiency of combined electrochemotherapy and single dose irradiation on a breast cancer tumor model
Background. The aim of this study was to investigate the antitumor effectiveness of electrochemotherapy with cisplatin
combined with suboptimal radiotherapy doses. Tumor radiosensitization was evaluated on large invasive ductal
carcinoma tumors in Balb/C mice.
Materials and methods. Tumors of an average volume of 630 mm3 were treated with cisplatin, electric pulses,
radiotherapy, electrochemotherapy, alone as well as in appropriate combinations. Tumors were irradiated with
Cobalt-60 γ-rays at doses 3 Gy and 5 Gy in combination with electrochemotherapy using cisplatin. Controls included
each of the treatments alone as well as the combination of the radiotherapy with electric pulses alone or with cisplatin
alone. Antitumor effectiveness was evaluated by tumor growth delay, tumor-doubling time, inhibition ratio and the
objective response rates.
Results. As anticipated, electrochemotherapy was more effective than the treatment with cisplatin alone or the application
of the electric pulses alone. When treatments were combined with tumor irradiation at either 3 or 5 Gy, the
combination with electrochemotherapy was more effective: at 5 Gy, 2 animals out of 8 were in complete remission
100 days later. In general the higher 5 Gy dose of γ-radiation was more effective than the lower one of 3 Gy.
Conclusions. The results of our study demonstrate that irradiation doses, 3 Gy or 5 Gy, increase the antitumor effectiveness
of electrochemotherapy with cisplatin on invasive ductal carcinoma tumors. Good antitumor results were
achieved in experimental tumors with a size comparable to clinical lesions, demonstrating that this three-modality
combined treatment is useful for the treatment of large lesions even at sub-optimal radiotherapy doses
H2 oxidation versus organic substrate oxidation in non-heme iron mediated reactions with H2O2
Herein we show that species generated upon reaction of α-[Fe(CF3SO3)2(BPMCN)] (BPMCN = N,N′-bis(2-pyridylmethyl)-trans-1,2-diaminocyclohexane) with H2O2 (putatively [FeV(O)(OH)(BPMCN)]) is able to efficiently oxidize H2 to H2O even in the presence of organic substrates, while species formed in the presence of acetic acid (putatively [FeV(O)(OAc)(BPMCN)]) prefer organic substrate oxidation over H2 activation. Mechanistic implications have been analysed with the aid of computational methodsThis work was supported by Spanish Ministerio de Economia y Competitividad (CTQ2012-37420-C02-02 and 01) European Research Council (StG 239910), and Generalitat de Catalunya (2014 SGR 862 and ICREA Academia award to MC). J.Ll.-F. thanks the CELLEX foundation for the starting career program for financial suppor
Reverse Δ-wave as a possible sign in electrocardiography to diagnose mitral valve prolapse
<p>Abstract</p> <p>Background</p> <p>Mitral valve prolapse (MVP) is defined as superior displacement of the mitral valve leaflets more than 2 mm into the left atrium during systole. Easier and cheaper assessment of this common disease is a priority in cardiac health care facilities.</p> <p>Presentation of the hypothesis</p> <p>In this study I addressed electrocardiographic presentation in 300 patients with MVP compared with 100 healthy individuals. I faced a novel finding in electrocardiogram (ECG) examination of these patients. It was a notch (reverse Δ-wave) in descending arm of QRS observed in 79% (237/300) of patients, consisting of 58% (174/300) in inferior leads and 21% (63/300) in I and aVL leads. The notch was identified only in 6 men in control group.</p> <p>Testing the hypothesis</p> <p>Considering the relatively higher prevalence of disease, a population-based diagnostic clinical trial study is appropriate to test the hypothesis.</p> <p>Implications of the hypothesis</p> <p>The hypothesis on diagnostic value of reverse Δ-wave in MVP may help in decreasing the rate of unnessessary echocardiography in some patients.</p
Preparation and Characterization of Mixed Halide MAPbI3−xClx Perovskite Thin Films by Three‐Source Vacuum Deposition
Chloride has been extensively used in the preparation of metal halide perovskites such as methylammonium lead iodide (MAPbI3-xClx), but its persistence and role in solution-processed materials has not yet been rationalized. Multiple-source vacuum deposition of perovskites enables a fine control over the thin-film stoichiometry, and allows to incorporate chemical species irrespectively of their solubility. In this communication, we present the first example of mixed MAPbI3-xClx thin films prepared by three-source vacuum deposition using MAI, PbI2 and PbCl2 as precursors. The optoelectronic properties of the material are evaluated through photovoltaic and electro-/photo-luminescent characterizations. Besides the very similar structural and optical properties of MAPbI3 and MAPbI3-xClx, we observed an increased electroluminescence efficiency, longer photoluminescence lifetimes, as well as larger photovoltage in the presence of chloride, suggesting a reduction of the non-radiative charge recombination
On the way to large-scale and high-resolution brain-chip interfacing
Brain-chip-interfaces (BCHIs) are hybrid entities where chips and nerve cells establish a close physical interaction allowing the transfer of information in one or both directions. Typical examples are represented by multi-site-recording chips interfaced to cultured neurons, cultured/acute brain slices, or implanted “in vivo”. This paper provides an overview on recent achievements in our laboratory in the field of BCHIs leading to enhancement of signals transmission from nerve cells to chip or from chip to nerve cells with an emphasis on in vivo interfacing, either in terms of signal-to-noise ratio or of spatiotemporal resolution. Oxide-insulated chips featuring large-scale and high-resolution arrays of stimulation and recording elements are presented as a promising technology for high spatiotemporal resolution interfacing, as recently demonstrated by recordings obtained from hippocampal slices and brain cortex in implanted animals. Finally, we report on an automated tool for processing and analysis of acquired signals by BCHIs
- …
