8,901 research outputs found
Towards the Modeling of Neuronal Firing by Gaussian Processes
This paper focuses on the outline of some computational methods for the
approximate solution of the integral equations for the neuronal firing
probability density and an algorithm for the generation of sample-paths in
order to construct histograms estimating the firing densities. Our results
originate from the study of non-Markov stationary Gaussian neuronal models with
the aim to determine the neuron's firing probability density function. A
parallel algorithm has been implemented in order to simulate large numbers of
sample paths of Gaussian processes characterized by damped oscillatory
covariances in the presence of time dependent boundaries. The analysis based on
the simulation procedure provides an alternative research tool when closed-form
results or analytic evaluation of the neuronal firing densities are not
available.Comment: 10 pages, 3 figures, to be published in Scientiae Mathematicae
Japonica
Role of the flat-designed surface in improving the cyclic fatigue resistance of endodontic NiTi rotary instruments
The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel-titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon-Mann-Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments
In vivo evaluation of operative torque generated by two Nickel-Titanium rotary instruments during root canal preparation
Objectives This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars. Materials and Methods Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). Statistical Analysis Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%. Results No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p > 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p < 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p < 0.05). Conclusions Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals
Ku & C Band solid state switch matrix for satellite payloads using LTCC multilayer substrate
This paper describes the design and development of Ku and C band solid state switch matrix for multimedia satellite payloads. The design, through the use of advanced packaging techniques, allows significant savings on mass and volume with respect to traditional electromechanical switches while guaranteeing a comparable reliability
Nazwy komitetów wyborczych – aspekty strukturalne i aksjologiczne
The subject of this paper will be a semantic and structural analysis of the names of electoral committees, and a reference to the axiological systems that are indirectly reflected by them. The names of electoral committees are obligatory elements of electoral activities, as well as being an interesting element of political marketing
Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study
Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones
Recovery of viral RNA and infectious foot-and-mouth disease virus from positive lateral-flow devices
Foot-and-mouth disease Virus (FMDV) is an economically important, highly contagious picornavirus that affects both wild and domesticated cloven hooved animals. In developing countries, the effective laboratory diagnosis of foot-and-mouth disease (FMD) is often hindered by inadequate sample preservation due to difficulties in the transportation and storage of clinical material. These factors can compromise the ability to detect and characterise FMD virus in countries where the disease is endemic. Furthermore, the high cost of sending infectious virus material and the biosecurity risk it presents emphasises the need for a thermo-stable, non-infectious mode of transporting diagnostic samples. This paper investigates the potential of using FMDV lateral-flow devices (LFDs) for dry transportation of clinical samples for subsequent nucleic acid amplification, sequencing and recovery of infectious virus by electroporation. FMDV positive samples (epithelial suspensions and cell culture isolates) representing four FMDV serotypes were applied to antigen LFDs: after which it was possible to recover viral RNA that could be detected using real-time RT-PCR. Using this nucleic acid, it was also possible to recover VP1 sequences and also successfully utilise protocols for amplification of complete FMD virus genomes. It was not possible to recover infectious FMDV directly from the LFDs, however following electroporation into BHK-21 cells and subsequent cell passage, infectious virus could be recovered. Therefore, these results support the use of the antigen LFD for the dry, non-hazardous transportation of samples from FMD endemic countries to international reference laboratories
Atrial natriuretic peptide effects on intracellular pH changes and ROS production in HEPG2 cells: Role of p38 MAPK and phospholipase D
Aims: The present study was performed to evaluate Atrial Natriuretic Peptide ( ANP) effects on intracellular pH, phospholipase D and ROS production and the possible relationship among them in HepG2 cells. Cancer extracellular microenvironment is more acidic than normal tissues and the activation of NHE- 1, the only system able to regulate pHi homeostasis in this condition, can represent an important event in cell proliferation and malignant transformation. Methods: The ANP effects on pHi were evaluated by fluorescence spectrometry. The effects on p38 MAPK and ROS production were evaluated by immunoblots and analysis of DCF- DA fluorescence, respectively. RT- PCR analysis and Western blotting were used to determine the ANP effect on mRNA NHE- 1 expression and protein levels. PLD- catalyzed conversion of phosphatidylcholine to phosphatydilethanol ( PetOH), in the presence of ethanol, was monitored by thin layer chromatography. Results: A significant pHi decrease was observed in ANP- treated HepG2 cells and this effect was paralleled by the enhancement of PLD activity and ROS production. The ANP effect on pHi was coupled to an increased p38 MAPK phosphorylation and a down- regulation of mRNA NHE- 1 expression and protein levels. Moreover, the relationship between PLD and ROS production was demonstrated by calphostin- c, a potent inhibitor of PLD. At the same time, all assessed ANP- effects were mediated by NPR- C receptors. Conclusion: Our results indicate that ANP recruits a signal pathway associated with p38 MAPK, NHE- 1 and PLD responsible for ROS production, suggesting a possible role for ANP as novel modulator of ROS generation in HepG2 cells. Copyright (C) 2005 S. Karger AG, Basel
- …
