188 research outputs found
Effects of 60 MeV protons and 250 kV X-rays on cell viability
Particle radiotherapy such as the one using proton beams, provides a successful treatment approach in many cancer types. However, the cellular and molecular mechanisms by which proton irradiation induces cell death, particularly in a human peripheral blood lymphocyte model has not been examined in detail. Comparative studies of the biological effects, such as cell death, of particle therapy versus conventional X-rays treatment are of utmost importance. Here, we compared the viability of human peripheral blood lymphocyte following in vitro irradiation with protons (therapeutic 60 MeV proton beam) and photon beam (250 kV, X-rays), by applying separate doses within the range of 0.3-4.0 Gy. Cell viability was assessed 1 and 4 h after irradiation with protons and X-rays by the FITC-Annexin V labelling procedure (Apoptotic & Necrotic & Healthy Cells Quantification Kit, Biotium). Results showed that irradiation with both radiation types reduced the number of viable cells in a dose-dependent manner, as assessed as a function of the duration of post-irradiation time. Protons proved more fatal to the cells treated than X-ray photons. This demonstrates a difference in cell viability after irradiation with protons and photons in a human peripheral blood lymphocyte model
Adherence measurements and corrosion resistance in primer/hot-dip galvanized steel systems
This paper focuses on the adherence during ageing of a primer (made of polyester resins crosslinked with melamine) applied onto hot-dip galvanized (HDG) steel for coil coating application and its influence on corrosion protection. A chromium-free surface treatment, composed of fluorotitanic acid, phosphoric acid, manganese phosphate, and vinylphenol was applied on the HDG steel to obtain high corrosion resistance and high adherence of a polyester and melamine primer. The influence of the manganese phosphate on the corrosion and adherence was investigated. To measure the adherence between the metal and the primer, a three-point flexure test was set up. The adherence was then linked with corrosion resistance during ageing, using electrochemical impedance spectroscopy
Impact of genetic traits on the occurrence of colorectal cancer : response to the challenging dose of X-rays in lymphocytes of colorectal cancer patients and healthy donors
Refining Treatment Planning in STereotactic Arrhythmia Radioablation (STAR): Benchmark Results and Consensus Statement from the STOPSTORM.eu Consortium.
BACKGROUND AND PURPOSE
STereotactic Arrhythmia Radioablation (STAR) showed promising results in patients with refractory ventricular tachycardia (VT). However, clinical data is scarce and heterogeneous. The STOPSTORM.eu consortium was established to investigate and harmonize STAR in Europe. The primary goal of this benchmark study was to investigate current treatment planning practice within the STOPSTORM project as a baseline for future harmonization.
METHODS
Planning target volumes (PTV) overlapping extra-cardiac organs-at-risk and/or cardiac substructures were generated for three STAR cases. Participating centers were asked to create single fraction treatment plans with 25 Gy dose prescription based on in-house clinical practice. All treatment plans were reviewed by an expert panel and quantitative crowd knowledge-based analysis was performed with independent software using descriptive statistics for ICRU report 91 relevant parameters and crowd dose-volume-histograms. Thereafter, treatment planning consensus statements were established using a dual-stage voting process.
RESULTS
Twenty centers submitted 67 treatment plans for this study. In most plans (75%) Intensity Modulated Arc Therapy (IMAT) with 6 MV flattening-filter-free beams was used. Dose prescription was mainly based on PTV D95% (49%) or D96-100% (19%). Many participants preferred to spare close extra-cardiac organs-at-risk (75%) and cardiac substructures (50%) by PTV coverage reduction. PTV D0.035cm3 ranged 25.5-34.6 Gy, demonstrating a large variety of dose inhomogeneity. Estimated treatment times without motion compensation or setup ranged 2-80 minutes. For the consensus statements, strong agreement was reached for beam technique planning, dose calculation, prescription methods and trade-offs between target and extra-cardiac critical structures. No agreement was reached on cardiac substructure dose limitations and on desired dose inhomogeneity in the target.
CONCLUSION
This STOPSTORM multi-center treatment planning benchmark study showed strong agreement on several aspects of STAR treatment planning, but also revealed disagreement on others. To standardize and harmonize STAR in the future, consensus statements were established, however clinical data is urgently needed for actionable guidelines for treatment planning
Refining Critical Structure Contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark Results and Consensus Guidelines from the STOPSTORM.eu Consortium.
BACKGROUND AND PURPOSE
In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre.
MATERIALS AND METHODS
Centres within the STOPSTORM consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95).
RESULTS
Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC=0.96, median MDA=0.1mm and median HD95=1.1mm) and aorta (median DSC=0.90, median MDA=0.1mm and median HD95=1.5mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC=0.83, median MDA=0.2mm and median HD95=0.5mm), valves (median DSC=0.16, median MDA=4.6mm and median HD95=16.0mm), coronary arteries (median DSC=0.4, median MDA=0.7mm and median HD95=8.3mm) and the sinoatrial and atrioventricular nodes (median DSC=0.29, median MDA=4.4mm and median HD95=11.4mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established.
CONCLUSION
This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established
Updated Prostate Cancer Risk Groups by Prostate-specific Membrane Antigen Positron Emission Tomography Prostate Cancer Molecular Imaging Standardized Evaluation (PPP2): Results from an International Multicentre Registry Study
Background and objectiveWe established prognostic nomograms incorporating prostate-specific membrane antigen (PSMA) positron emission tomography (PET) parameters standardised by Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE; PPP1). Here, we develop an updated PPP2 risk score from a large international multicentre registry study.MethodsWe included 6128 prostate cancer patients who underwent PSMA-PET at 20 hospitals in Europe, USA, and Australia between 2013 and 2022. Investigator sites were split 2:1 into the development (4044 patients) and validation (2084 patients) cohorts. We created nomograms of version 2 (PPP2) based on Cox regression models with the least absolute shrinkage and selection operator penalty for overall survival (development cohort). Performance of both nomograms was measured using Harrell's C-index and calibration plots and a head-to-head comparison with the National Comprehensive Cancer Network (NCCN) risk score by receiver operating characteristic curves (validation cohort).Key findings and limitationsPredictors were distant metastases (extrapelvic nodal metastases [M1a], bone metastases [M1b], and visceral metastases [M1c]), PSMA expression score, and total lesion count (visual PPP2) or total tumour volume (quantitative PPP2). C-indices (95% confidence interval) in the validation cohort were 0.80 (0.78-0.82; visual) and 0.80 (0.79-0.82; quantitative), respectively. Accuracy of both the PPP2 nomograms was superior to the NCCN risk score (n = 1034, area under the curve 0.84 vs 0.76; p < 0.001). The retrospective design represents a limitation of the study.Conclusions and clinical implicationsPPP nomograms were improved in an international multicentre study to predict accurately the 3- and 5-yr overall survival probabilities of prostate cancer. PPP2 yielded superior accuracy to the NCCN risk score. A free software tool has been created for PROMISE and PPP2 assessments (promise-pet.org)
The effectiveness and side effects of conformal external beam radiotherapy combined with high-dose-rate brachytherapy boost compared to conformal external beam radiotherapy alone in patients with prostate cancer
Refining critical structure contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark results and consensus guidelines from the STOPSTORM.eu consortium
BACKGROUND AND PURPOSE: In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS: Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS: Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION: This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established
Stereotactic linac radiosurgery and hypofractionated stereotactic radiotherapy for pediatric arteriovenous malformations of the brain: experiences of a single institution
- …
