5,108 research outputs found

    Test beam Characterizations of 3D Silicon Pixel detectors

    Full text link
    3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders them particularly interesting to be used in environments where standard silicon detectors have limitations, such as for example the radiation environment expected in an LHC upgrade. For the first time, several 3D sensors were assembled as hybrid pixel detectors using the ATLAS-pixel front-end chip and readout electronics. Devices with different electrode configurations have been characterized in a 100 GeV pion beam at the CERN SPS. Here we report results on unirradiated devices with three 3D electrodes per 50 x 400 um2 pixel area. Full charge collection is obtained already with comparatively low bias voltages around 10 V. Spatial resolution with binary readout is obtained as expected from the cell dimensions. Efficiencies of 95.9% +- 0.1 % for tracks parallel to the electrodes and of 99.9% +- 0.1 % at 15 degrees are measured. The homogeneity of the efficiency over the pixel area and charge sharing are characterized.Comment: 5 pages, 7 figure

    Magnetically asymmetric interfaces in a (LaMnO3_3)/(SrMnO3_3) superlattice due to structural asymmetries

    Full text link
    Polarized neutron reflectivity measurements of a ferromagnetic [(LaMnO3_3)11.8_{11.8}/(SrMnO3_3)4.4_{4.4}]6_6 superlattice reveal a modulated magnetic structure with an enhanced magnetization at the interfaces where LaMnO3_3 was deposited on SrMnO3_3 (LMO/SMO). However, the opposite interfaces (SMO/LMO) are found to have a reduced ferromagnetic moment. The magnetic asymmetry arises from the difference in lateral structural roughness of the two interfaces observed via electron microscopy, with strong ferromagnetism present at the interfaces that are atomically smooth over tens of nanometers. This result demonstrates that atomic-scale roughness can destabilize interfacial phases in complex oxide heterostructures.Comment: 5 pages, 4 figure

    A apicultura nas regiões tropicais

    Get PDF

    Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

    Get PDF
    While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.Comment: 16 pages, 13 figure

    Magnetic Structure in Fe/Sm-Co Exchange Spring Bilayers with Intermixed Interfaces

    Full text link
    The depth profile of the intrinsic magnetic properties in an Fe/Sm-Co bilayer fabricated under nearly optimal spring-magnet conditions was determined by complementary studies of polarized neutron reflectometry and micromagnetic simulations. We found that at the Fe/Sm-Co interface the magnetic properties change gradually at the length scale of 8 nm. In this intermixed interfacial region, the saturation magnetization and magnetic anisotropy are lower and the exchange stiffness is higher than values estimated from the model based on a mixture of Fe and Sm-Co phases. Therefore, the intermixed interface yields superior exchange coupling between the Fe and Sm-Co layers, but at the cost of average magnetization.Comment: 16 pages, 6 figures and 1 tabl

    L’apiculture dans les zones tropicales

    Get PDF

    Beekeeping in the tropics

    Get PDF

    Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector

    Get PDF
    For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with five intermediate strips (20 micron strip pitch). An extensive test program has been carried out at the DESY-II testbeam facility. In this paper we describe the setup developed to test the ZEUS MVD sensors and the results obtained on both irradiated and non-irradiated single sided micro-strip detectors with rectangular and trapezoidal geometries. The performances of the sensors coupled to the readout electronics (HELIX chip, version 2.2) have been studied in detail, achieving a good description by a Monte Carlo simulation. Measurements of the position resolution as a function of the angle of incidence are presented, focusing in particular on the comparison between standard and newly developed reconstruction algorithms.Comment: 41 pages, 21 figures, 2 tables, accepted for publication in NIM
    corecore