215 research outputs found
Experimental measurement of photothermal effect in Fabry-Perot cavities
We report the experimental observation of the photothermal effect. The
measurements are performed by modulating the laser power absorbed by the
mirrors of two high-finesse Fabry-Perot cavities. The results are very well
described by a recently proposed theoretical model [M. Cerdonio, L. Conti, A.
Heidmann and M. Pinard, Phys. Rev. D 63 (2001) 082003], confirming the
correctness of such calculations. Our observations and quantitative
characterization of the photothermal effect demonstrate its critical importance
for high sensitivity interferometric displacement measurements, as those
necessary for gravitational wave detection.Comment: 4 pages, 3 figures, submitted to Phys. Rev. Let
Room temperature GW bar detector with opto-mechanical readout
We present the full implementation of a room-temperature gravitational wave
bar detector equipped with an opto-mechanical readout. The mechanical
vibrations are read by a Fabry--Perot interferometer whose length changes are
compared with a stable reference optical cavity by means of a resonant laser.
The detector performance is completely characterized in terms of spectral
sensitivity and statistical properties of the fluctuations in the system output
signal. The new kind of readout technique allows for wide-band detection
sensitivity and we can accurately test the model of the coupled oscillators for
thermal noise. Our results are very promising in view of cryogenic operation
and represent an important step towards significant improvements in the
performance of massive gravitational wave detectors.Comment: 7 figures, submitted to Phys. Rev.
Selective readout and back-action reduction for wideband acoustic gravitational wave detectors
We present the concept of selective readout for broadband resonant mass
gravitational wave detectors. This detection scheme is capable of specifically
selecting the signal from the contributions of the vibrational modes sensitive
to the gravitational waves, and efficiently rejecting the contribution from non
gravitationally sensitive modes. Moreover this readout, applied to a dual
detector, is capable to give an effective reduction of the back-action noise
within the frequency band of interest. The overall effect is a significant
enhancement in the predicted sensitivity, evaluated at the standard quantum
limit for a dual torus detector. A molybdenum detector, 1 m in diameter and
equipped with a wide area selective readout, would reach spectral strain
sensitivities 2x10^{-23}/sqrt{Hz} between 2-6 kHz.Comment: 9 pages, 4 figure
Ion mobility discontinuities in superfluid helium: A test of the Huang-Olinto theory
A new method has been developed for making sensitive differential measurements of ion mobilities in liquid helium. Using this method, it has been possible to make a definitive test of the part of the Huang-Olinto theory intended to explain discontinuities in ion mobilities in superfluid helium. The theory has been found to be incorrect
Thermal and back-action noises in dual-sphere gravitational-waves detectors
We study the sensitivity limits of a broadband gravitational-waves detector
based on dual resonators such as nested spheres. We determine both the thermal
and back-action noises when the resonators displacements are read-out with an
optomechanical sensor. We analyze the contributions of all mechanical modes,
using a new method to deal with the force-displacement transfer functions in
the intermediate frequency domain between the two gravitational-waves sensitive
modes associated with each resonator. This method gives an accurate estimate of
the mechanical response, together with an evaluation of the estimate error. We
show that very high sensitivities can be reached on a wide frequency band for
realistic parameters in the case of a dual-sphere detector.Comment: 10 pages, 7 figure
Wideband dual sphere detector of gravitational waves
We present the concept of a sensitive AND broadband resonant mass
gravitational wave detector. A massive sphere is suspended inside a second
hollow one. Short, high-finesse Fabry-Perot optical cavities read out the
differential displacements of the two spheres as their quadrupole modes are
excited. At cryogenic temperatures one approaches the Standard Quantum Limit
for broadband operation with reasonable choices for the cavity finesses and the
intracavity light power. A molybdenum detector of overall size of 2 m, would
reach spectral strain sensitivities of 2x10^-23/Sqrt{Hz} between 1000 Hz and
3000 Hz.Comment: 4 pages, 3 figures. Changed content. To appear in Phys. Rev. Let
Modulation of LISA free-fall orbits due to the Earth-Moon system
We calculate the effect of the Earth-Moon (EM) system on the free-fall motion
of LISA test masses. We show that the periodic gravitational pulling of the EM
system induces a resonance with fundamental frequency 1 yr^-1 and a series of
periodic perturbations with frequencies equal to integer harmonics of the
synodic month (9.92 10^-7 Hz). We then evaluate the effects of these
perturbations (up to the 6th harmonics) on the relative motions between each
test masses couple, finding that they range between 3mm and 10pm for the 2nd
and 6th harmonic, respectively. If we take the LISA sensitivity curve, as
extrapolated down to 10^-6 Hz, we obtain that a few harmonics of the EM system
can be detected in the Doppler data collected by the LISA space mission. This
suggests that the EM system gravitational near field could provide an absolute
calibration for the LISA sensitivity at very low frequencies.Comment: 15 pages, 5 figure
- …
