248 research outputs found

    Tin dioxide sol-gel derived thin films deposited on porous silicon

    Get PDF
    Undoped and Sb-doped SnO2 sol¿gel derived thin films have been prepared for the first time from tin (IV) ethoxide precursor and SbCl3 in order to be utilised for gas sensing applications where porous silicon is used as a substrate. Transparent, crack-free and adherent layers were obtained on different types of substrates (Si, SiO2/Si). The evolution of the Sn¿O chemical bonds in the SnO2 during film consolidation treatments was monitored by infrared spectroscopy. By energy dispersive X-ray spectroscopy performed on the cross section of the porosified silicon coupled with transmission electron microscopy, the penetration of the SnO2 sol¿gel derived films in the nanometric pores of the porous silicon has been experimentally proved

    Isospin Diffusion in 58^{58}Ni-Induced Reactions at Intermediate Energies

    Get PDF
    Isospin diffusion is probed as a function of the dissipated energy by studying two systems 58^{58}Ni+58^{58}Ni and 58^{58}Ni+197^{197}Au, over the incident energy range 52-74\AM. Experimental data are compared with the results of a microscopic transport model with two different parameterizations of the symmetry energy term. A better overall agreement between data and simulations is obtained when using a symmetry term with a potential part linearly increasing with nuclear density. The isospin equilibration time at 52 \AM{} is estimated to 130±\pm10 fm/cc

    Estimate of average freeze-out volume in multifragmentation events

    Get PDF
    An estimate of the average freeze-out volume for multifragmentation events is presented. Values of volumes are obtained by means of a simulation using the experimental charged product partitions measured by the 4pi multidetector INDRA for 129Xe central collisions on Sn at 32 AMeV incident energy. The input parameters of the simulation are tuned by means of the comparison between the experimental and simulated velocity (or energy) spectra of particles and fragments.Comment: To be published in Phys. Lett. B 12 pages, 5 figure

    Isospin diffusion in semi-peripheral 58Ni^{58}Ni + 197Au^{197}Au collisions at intermediate energies (I): Experimental results

    Get PDF
    Isospin diffusion in semi-peripheral collisions is probed as a function of the dissipated energy by studying two systems 58Ni^{58}Ni + 58Ni^{58}Ni and 58Ni^{58}Ni + 197Au^{197}Au, over the incident energy range 52-74\AM. A close examination of the multiplicities of light products in the forward part of phase space clearly shows an influence of the isospin of the target on the neutron richness of these products. A progressive isospin diffusion is observed when collisions become more central, in connection with the interaction time

    Break-up stage restoration in multifragmentation reactions

    Full text link
    In the case of Xe+Sn at 32 MeV/nucleon multifragmentation reaction break-up fragments are built-up from the experimentally detected ones using evaluations of light particle evaporation multiplicities which thus settle fragment internal excitation. Freeze-out characteristics are extracted from experimental kinetic energy spectra under the assumption of full decoupling between fragment formation and energy dissipated in different degrees of freedom. Thermal kinetic energy is determined uniquely while for freeze-out volume - collective energy a multiple solution is obtained. Coherence between the solutions of the break-up restoration algorithm and the predictions of a multifragmentation model with identical definition of primary fragments is regarded as a way to select the true value. The broad kinetic energy spectrum of 3^3He is consistent with break-up genesis of this isotope.Comment: 17 pages, 5 figure

    Transition from participant to spectator fragmentation in Au+Au reaction between 60 AMeV and 150 AMeV

    Full text link
    Using the quantum molecular dynamics approach, we analyze the results of the recent INDRA Au+Au experiments at GSI in the energy range between 60 AMeV and 150 AMeV. It turns out that in this energy region the transition toward a participant-spectator scenario takes place. The large Au+Au system displays in the simulations as in the experiment simultaneously dynamical and statistical behavior which we analyze in detail: The composition of fragments close to midrapidity follows statistical laws and the system shows bi-modality, i.e. a sudden transition between different fragmentation pattern as a function of the centrality as expected for a phase transition. The fragment spectra at small and large rapidities, on the other hand, are determined by dynamics and the system as a whole does not come to equilibrium, an observation which is confirmed by FOPI experiments for the same system.Comment: published versio

    Energy measurement and fragment identification using digital signals from partially depleted Si detectors

    Get PDF
    A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the DE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector whose doping uniformity is not good enough for isotopic identification at full depletion.Comment: 13 pages, 10 figures 5 tables; submitted to European Physical Journal
    corecore