575 research outputs found
New Exclusion Limits for the Search of Scalar and Pseudoscalar Axion-Like Particles from "Light Shining Through a Wall"
Physics beyond the Standard Model predicts the possible existence of new
particles that can be searched at the low energy frontier in the sub-eV range.
The OSQAR photon regeneration experiment looks for "Light Shining through a
Wall" from the quantum oscillation of optical photons into "Weakly Interacting
Sub-eV Particles", such as axion or Axion-Like Particles (ALPs), in a 9 T
transverse magnetic field over the unprecedented length of m.
In 2014, this experiment has been run with an outstanding sensitivity, using an
18.5 W continuous wave laser emitting in the green at the single wavelength of
532 nm. No regenerated photons have been detected after the wall, pushing the
limits for the existence of axions and ALPs down to an unprecedented level for
such a type of laboratory experiment. The di-photon couplings of possible
pseudo-scalar and scalar ALPs can be constrained in the nearly massless limit
to be less than GeV and
GeV, respectively, at 95% Confidence Level.Comment: 6 pages, 6 figure
Search for weakly interacting sub-eV particles with the OSQAR laser-based experiment: results and perspectives
Recent theoretical and experimental studies highlight the possibility of new
fundamental particle physics beyond the Standard Model that can be probed by
sub-eV energy experiments. The OSQAR photon regeneration experiment looks for
"Light Shining through a Wall" (LSW) from the quantum oscillation of optical
photons into "Weakly Interacting Sub-eV Particles" (WISPs), like axion or
axion-like particles (ALPs), in a 9 T transverse magnetic field over the
unprecedented length of m. No excess of events has been
detected over the background. The di-photon couplings of possible new light
scalar and pseudo-scalar particles can be constrained in the massless limit to
be less than GeV. These results are very close to the
most stringent laboratory constraints obtained for the coupling of ALPs to two
photons. Plans for further improving the sensitivity of the OSQAR experiment
are presented.Comment: 7 pages, 7 figure
Fast photon detection for the COMPASS RICH detector
The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring
Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a
wide momentum range. For the data taking in 2006, the COMPASS RICH has been
upgraded in the central photon detection area (25% of the surface) with a new
technology to detect Cherenkov photons at very high count rates of several 10^6
per second and channel and a new dead-time free read-out system, which allows
trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of
576 visible and ultra-violet sensitive multi-anode photomultipliers with 16
channels each. The upgraded detector showed an excellent performance during the
2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06
The Fast Read-out System for the MAPMTs of COMPASS RICH-1
A fast readout system for the upgrade of the COMPASS RICH detector has been
developed and successfully used for data taking in 2006 and 2007. The new
readout system for the multi-anode PMTs in the central part of the photon
detector of the RICH is based on the high-sensitivity MAD4
preamplifier-discriminator and the dead-time free F1-TDC chip characterized by
high-resolution. The readout electronics has been designed taking into account
the high photon flux in the central part of the detector and the requirement to
run at high trigger rates of up to 100 kHz with negligible dead-time. The
system is designed as a very compact setup and is mounted directly behind the
multi-anode photomultipliers. The data are digitized on the frontend boards and
transferred via optical links to the readout system. The read-out electronics
system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor
change
Multi-layer scintillation detector for the MOON double beta decay experiment: Scintillation photon responses studied by a prototype detector MOON-1
An ensemble of multi-layer scintillators is discussed as an option of the
high-sensitivity detector Mo Observatory Of Neutrinos (MOON) for spectroscopic
measurements of neutrino-less double beta decays. A prototype detector MOON-1,
which consists of 6 layer plastic-scintillator plates, was built to study the
sensitivity of the MOON-type detector. The scintillation photon collection and
the energy resolution, which are key elements for the high-sensitivity
experiments, are found to be 1835+/-30 photo-electrons for 976 keV electrons
and sigma = 2.9+/-0.1% (dE/E = 6.8+/-0.3 % in FWHM) at the Qbb ~ 3 MeV region,
respectively. The multi-layer plastic-scintillator structure with good energy
resolution as well as good background suppression of beta-gamma rays is crucial
for the MOON-type detector to achieve the inverted hierarchy neutrino mass
sensitivity.Comment: 8 pages, 16 figures, submitted to Nucl.Instrum.Met
Interplay among transversity induced asymmetries in hadron leptoproduction
In the fragmentation of a transversely polarized quark several left-right
asymmetries are possible for the hadrons in the jet. When only one unpolarized
hadron is selected, it exhibits an azimuthal modulation known as Collins
effect. When a pair of oppositely charged hadrons is observed, three
asymmetries can be considered, a di-hadron asymmetry and two single hadron
asymmetries. In lepton deep inelastic scattering on transversely polarized
nucleons all these asymmetries are coupled with the transversity distribution.
From the high statistics COMPASS data on oppositely charged hadron-pair
production we have investigated for the first time the dependence of these
three asymmetries on the difference of the azimuthal angles of the two hadrons.
The similarity of transversity induced single and di-hadron asymmetries is
discussed. A new analysis of the data allows to establish quantitative
relationships among them, providing for the first time strong experimental
indication that the underlying fragmentation mechanisms are all driven by a
common physical process.Comment: 6 figure
Measurement of the charged-pion polarisability
The COMPASS collaboration at CERN has investigated pion Compton scattering,
, at centre-of-mass energy below 3.5 pion
masses. The process is embedded in the reaction
, which is initiated by
190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons
is selected by isolating the sharp Coulomb peak observed at smallest momentum
transfers, \,(GeV/). From a sample of 63\,000 events the
pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\
0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times
10^{-4}\,\mbox{fm}^3\alpha_\pi=-\beta_\pi$, which
relates the electric and magnetic dipole polarisabilities. It is the most
precise measurement of this fundamental low-energy parameter of strong
interaction, that has been addressed since long by various methods with
conflicting outcomes. While this result is in tension with previous dedicated
measurements, it is found in agreement with the expectation from chiral
perturbation theory. An additional measurement replacing pions by muons, for
which the cross-section behavior is unambigiously known, was performed for an
independent estimate of the systematic uncertainty.Comment: Published version: 9 pages, 3 figures, 1 tabl
Measurement of the Longitudinal Spin Transfer to Lambda and Anti-Lambda Hyperons in Polarised Muon DIS
The longitudinal polarisation transfer from muons to lambda and anti-lambda
hyperons, D_LL, has been studied in deep inelastic scattering off an
unpolarised isoscalar target at the COMPASS experiment at CERN. The spin
transfers to lambda and anti-lambda produced in the current fragmentation
region exhibit different behaviours as a function of x and xF . The measured x
and xF dependences of D^lambda_LL are compatible with zero, while
D^anti-lambda_LL tends to increase with xF, reaching values of 0.4 - 0.5. The
resulting average values are D^lambda_LL = -0.012 +- 0.047 +- 0.024 and
D^anti-lambda_LL = 0.249 +- 0.056 +- 0.049. These results are discussed in the
frame of recent model calculations.Comment: 13 pages, 7 figure
Fast Photon Detection for Particle Identification with COMPASS RICH-1
Particle identification at high rates is an important challenge for many
current and future high-energy physics experiments. The upgrade of the COMPASS
RICH-1 detector requires a new technique for Cherenkov photon detection at
count rates of several per channel in the central detector region, and a
read-out system allowing for trigger rates of up to 100 kHz. To cope with these
requirements, the photon detectors in the central region have been replaced
with the detection system described in this paper. In the peripheral regions,
the existing multi-wire proportional chambers with CsI photocathode are now
read out via a new system employing APV pre-amplifiers and flash ADC chips. The
new detection system consists of multi-anode photomultiplier tubes (MAPMT) and
fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip.
The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run.
We present the photon detection design, constructive aspects and the first
Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30
June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption
of Fig.
- …
