3,282 research outputs found
Radio Polarisation Study of High Rotation Measure AGNs
As radio polarised emission from astrophysical objects traverse through
foreground magnetised plasma, the physical conditions along the lines of sight
are encrypted in the form of Rotation Measure (RM). We performed broadband
spectro-polarimetric observations of high Rotation Measure (|RM| >~ 300 rad
m-2) sources away from the Galactic plane (|b| > 10 deg) selected from the NVSS
RM catalogue. The main goals are to verify the NVSS RM values, which could be
susceptible to n{\pi}-ambiguity, as well as to identify the origin of the
extreme RM values. We show that 40 % of our sample suffer from n{\pi}-ambiguity
in the NVSS RM catalogue. There are also hints of RM variabilities over ~20
years epoch for most of our sources, as revealed by comparing the RM values of
the two studies in the same frequency ranges after correcting for
n{\pi}-ambiguity. At last, we demonstrate the possibility of applying
QU-fitting to study the ambient media of AGNs.Comment: 6 pages, 2 figures; Accepted by MDPI Galaxies; Conference Proceedings
for the Polarised Emission from Astrophysical Jets meeting on June 12-16
2017, Ierapetra, Greec
Development of 3D Sculpted, Hyper-Realistic Biomimetic Eyes for Humanoid Robots and Medical Ocular Prostheses
Abstract. Hyper-realistic Humanoid Bio-robotic Systems (HHBS) are the precise electro-mechanical bodily emulation of natural human being in materiality, form and function. However, the standardised approach of constructing static ocular prosthesis for implementation in modern HHBS design, contradicts innate organic human criterion as the artificial eyes are void of the intricate dynamic fluidic functions of the natural human iris. The aim of this paper is to outline the development and construction process of a pair of realistic artificial humanistic optical retinal sensors that accurately simulate the autonomous fluctuating operations of the human iris in reaction to visceral emotion and photo-luminescent stimuli and retain the optical sensory capability and integral aesthetic materialism of the organic eye. The objective of the auto-dynamic pupillary framework is to advance the external
expressive / embodied realism of HHBS towards achieving a more accurate operational and embodied simulation. Prospective future application and advancement of the outlined optical system presents potential implementation in the field of medical ocular prosthetic design, with the aim of enhancing the naturalistic operations of future fabricated human eye replicas, thus conceivably reducing the malaise and discomfiture commonly associated with the archetypical fixed artificial eyes
Covalently bonded interfaces for polymer/graphene composites
The interface is well known for taking a critical role in the determination of the functional and mechanical properties of polymer composites. Previous interface research has focused on utilising reduced graphene oxide that is limited by a low structural integrity, which means a high fraction is needed to produce electrically conductive composites. By using 4,40-diaminophenylsulfone, we in this study chemically modified high-structural integrity graphene platelets (GnPs) of 2–4 nm in thickness, covalently bonded GnPs with an epoxy matrix, and investigated the morphology and functional and mechanical performance of these composites. This covalently bonded interface prevented GnPs stacking in the matrix. In comparison with unmodified composites showing no reduction in electrical volume resistivity, the interface-modified composite at 0.489 vol% GnPs demonstrates an eight-order reduction in the resistivity, a 47.7% further improvement in modulus and 84.6% in fracture energy release rate. Comparison of GnPs with clay and multi-walled carbon nanotubes shows that our GnPs are more advantageous in terms of performance and cost. This study provides a novel method for developing interface-tuned polymer/graphene composites
Bi- and tri-dentate imino-based iron and cobalt pre-catalysts for ethylene oligo-/polymerization
Recent progress on the use of iron and cobalt complex pre-catalysts for ethylene reactivity is reviewed. The review is organized in terms of the denticity of the chelate ligands employed, with particular reference to the influence of the ligand frameworks and their substituents on the catalytic performance for ethylene oligomerization/polymerization catalysis. The majority of the systems bear tri-dentate ligation at the iron/cobalt centre, though it is clear that bi-dentate iron/cobalt complex pre-catalysts have also attracted significant attention. Such systems produce in most cases highly linear products ranging from oligomeric α-olefins to high molecular weight polyethylene, and as such are promising candidates for both academic and industrial considerations
HIV and Hepatitis C-Coinfected Patients Have Lower Low-Density Lipoprotein Cholesterol Despite Higher Proprotein Convertase Subtilisin Kexin 9 (PCSK9): An Apparent "PCSK9-Lipid Paradox".
BackgroundProprotein convertase subtilisin kexin 9 (PCSK9) inhibitors reduce low-density lipoprotein cholesterol (LDL-C) and improve outcomes in the general population. HIV-infected individuals are at increased risk for cardiovascular events and have high rates of dyslipidemia and hepatitis C virus (HCV) coinfection, making PCSK9 inhibition a potentially attractive therapy.Methods and resultsWe studied 567 participants from a clinic-based cohort to compare PCSK9 levels in patients with HIV/HCV coinfection (n=110) with those with HIV infection alone (n=385) and with uninfected controls (n=72). The mean age was 49 years, and the median LDL-C level was 100 mg/dL (IQR 77-124 mg/dL); 21% were taking statins. The 3 groups had similar rates of traditional risk factors. Total cholesterol, LDL-C, and high-density lipoprotein cholesterol levels were lower in coinfected patients compared with controls (P<0.001). PCSK9 was 21% higher in HIV/HCV-coinfected patients versus controls (95% CI 9-34%, P<0.001) and 11% higher in coinfected individuals versus those with HIV infection alone (95% CI 3-20%, P=0.008). After adjustment for cardiovascular risk factors, HIV/HCV coinfection remained significantly associated with 20% higher PCSK9 levels versus controls (95% CI 8-33%, P=0.001). Interleukin-6 levels increased in a stepwise fashion from controls (lowest) to HIV-infected to HIV/HCV-coinfected individuals (highest) and correlated with PCSK9 (r=0.11, P=0.018).ConclusionsDespite having lower LDL-C, circulating PCSK9 levels were increased in patients coinfected with HIV and HCV in parallel with elevations in the inflammatory, proatherogenic cytokine interleukin-6. Clinical trials should be conducted to determine the efficacy of targeted PCSK9 inhibition in the setting of HIV/HCV coinfection
Impact of Bt Cotton in China
A sample of 283 cotton farmers in Northern China was surveyed in December 1999. Farmers that used cotton engineered to produce the Bacillus thuringiensis (Bt) toxin substantially reduced the use of pesticide without reducing the output/ha or quality of cotton. This resulted in substantial economic benefits for small farmers. Consumers did not benefit directly. Farmers obtained the major share of benefits and because of weak intellectual property rights very little went back to government research institutes or foreign firms that developed these varieties. Farmers using Bt cotton reported fewer pesticide poisonings than those using conventional cotton.biotechnology, cotton, Asia, China, agriculture, economics
Contralateral manual compensation for velocity-dependent force perturbations
It is not yet clear how the temporal structure of a voluntary action is coded allowing coordinated bimanual responses. This study focuses on the adaptation to and compensation for a force profile presented to one stationary arm which is proportional to the velocity of the other moving arm. We hypothesised that subjects would exhibit predictive coordinative responses which would co-vary with the state of the moving arm. Our null hypothesis is that they develop a time-dependent template of forces appropriate to compensate for the imposed perturbation. Subjects were trained to make 500 ms duration reaching movements with their dominant right arm to a visual target. A force generated with a robotic arm that was proportional to the velocity of the moving arm and perpendicular to movement direction acted on their stationary left hand, either at the same time as the movement or delayed by 250 or 500 ms. Subjects rapidly learnt to minimise the final end-point error. In the delay conditions, the left hand moved in advance of the onset of the perturbing force. In test conditions with faster or slower movement of the right hand, the predictive actions of the left hand co-varied with movement speed. Compensation for movement-related forces appeared to be predictive but not based on an accurate force profile that was equal and opposite to the imposed perturbatio
Selective ethylene trimerization by titanium complexes bearing phenoxy-imine ligands: NMR and EPR Spectroscopic studies of the reaction intermediates
The catalyst systems (FI)TiCl₃/MAO (FI = phenoxyimine ligand with an additional aryl–O–CH₃ donor) display exceptionally high activity in selective ethylene trimerization. By means of NMR and EPR spectroscopy, the nature of the Ti species formed in the catalyst systems (FI)TiCl₃/MAO, (FI)TiCl₃/MMAO, and (FI)TiCl₃/AlR₃/[Ph₃C]⁺[B(C₆F₅)₄]⁻ (R = Me, Et, ⁱBu) has been studied. It was shown that outer-sphere ion pairs of the type [(FI)TiIVMe₂]⁺[A]⁻ ([A]− = [MeMAO]⁻, [MeMMAO]⁻, [B(C₆F₅)₄]⁻) are formed at the initial stage of the reaction of (FI)TiCl₃ with MAO, MMAO, and AlMe₃/[Ph₃C]⁺[B(C₆F₅)₄]⁻. These ion pairs further partially convert into TiIII and TiII species. In the systems (FI)TiCl₃/MAO and (FI)TiCl₃/AlMe₃/[Ph₃C]⁺[B(C₆F5)₄]⁻, complexes with the proposed structures (FI)TiIIIMe₂, (FI)TiIICl, and [(FI)TiII(S)]⁺[A]⁻ ([A]− = [MeMAO]⁻, [B(C₆F₅)4)]⁻, S = solvent, vacancy) were observed (concentrations of TiIII species was lower than those of the TiII congeners). In contrast, in the system (FI)TiCl₃/MMAO, the concentrations of TiIII species (ion pairs of the type [(FI)TiIII(μ-H)(μ-Cl)AlⁱBu₂]⁺[MeMMAO]⁻) were higher than those of the TiII counterparts (ion pairs [(FI)TiII(S)]⁺[MeMMAO]⁻). The system (FI)TiCl₃/MMAO displays lower activity and selectivity in 1-hexene formation, in comparison to (FI)TiCl₃/MAO, due to undesirable PE generation. Probably, TiII and TiIV ion pairs are those participating in ethylene trimerization
- …
