38 research outputs found
Interference of partial visual analysis of root filling quality and apical status on retreatment decisions
OBJECTIVE: The presence of periapical radiolucency has been used as a criterion for endodontic treatment failure. However, in addition to the inherent limitations of radiographic examinations, radiographic interpretations are extremely subjective. Thus, this study investigated the effect of partial analysis of root filling quality and periapical status on retreatment decisions by general dentists. MATERIAL AND METHODS: Twelve digitalized periapical radiographs were analyzed by 10 observers. The study was conducted at three time points at 1-week intervals. Radiographs edited with the Adobe Photoshop CS4 software were analyzed at three time points: first, only root filling quality was analyzed; second, only the periapical areas of the teeth under study were visualized; finally, observers analyzed the unedited radiographic image. Spearman's coefficient was used to analyze the correlations between the scores assigned when the periapical area was not visible and when the unedited radiograph was analyzed, as well as between the scores assigned when root fillings where not visible and when the unedited radiograph was analyzed. Sensitivity, specificity, positive and negative predictive values between partial images and unedited radiographs were also used to analyze retreatment decisions. The level of significance was set at 5%. RESULTS: The visualization of the root filling on the unedited radiograph affected the interpretation of the periapical status and the technical quality of the fillings has a greater influence on the general dentist's decision to prescribe endodontic retreatment than the periapical condition. CONCLUSION: In order to make endodontic diagnosis, radiographic interpretation process should not only emphasize technical aspects, but also consider biological factors
QMix® irrigant reduces lipopolysacharide (LPS) levels in an in vitro model
AbstractThe presence of endotoxin inside the root canal has been associated with periapical inflammation, bone resorption and symptomatic conditions.Objectives To determine, in vitro, the effect of QMix® and other three root canal irrigants in reducing the endotoxin content in root canals.Material and Methods Root canals of single-rooted teeth were prepared. Samples were detoxified with Co-60 irradiation and inoculated with E. coli LPS (24 h, at 37°C). After that period, samples were divided into 4 groups, according to the irrigation solution tested: QMix®, 17% EDTA, 2% chlorhexidine solution (CHX), and 3% sodium hypochlorite (NaOCl). LPS quantification was determined by Limulus Amebocyte Lysate (LAL) assay. The initial counting of endotoxins for all samples, and the determination of LPS levels in non-contaminated teeth and in contaminated teeth exposed only to non-pyrogenic water, were used as controls.Results QMix® reduced LPS levels, with a median value of 1.11 endotoxins units (EU)/mL (p<0.001). NaOCl (25.50 EU/mL), chlorhexidine (44.10 EU/mL) and positive control group (26.80 EU/mL) samples had similar results. Higher levels were found with EDTA (176.00 EU/mL) when compared to positive control (p<0.001). There was no significant difference among EDTA, NaOCl and CHX groups. Negative control group (0.005 EU/mL) had statistically significant lower levels of endotoxins when compared to all test groups (p<0.001).Conclusion QMix® decreased LPS levels when compared to the other groups (p<0.001). 3% NaOCl, 2% CHX and 17% EDTA were not able to significantly reduce the root canal endotoxins load
Structural and geochronological constraints on the evolution of the Juréia Massif, Registro Domain, State of São Paulo, Brazil
Antibacterial effectiveness of peracetic acid and conventional endodontic irrigants
Este estudo avaliou, in vitro, a atividade antibacteriana de soluções irrigadoras convencionais e experimentais sobre Enterecoccus faecalis. As seguintes substâncias foram avaliadas por teste de contato direto: hipoclorito de sódio (NaOCl) a 2,5%, clorexidina (CHX) a 2%, ácido peracético a 1%. Após diferentes períodos de contato (30 s, 1, 3 e 10 min), um agente neutralizante foi empregado. Diluições decimais seriadas foram realizadas e semeadas em placas de tryptic soy agar (TSA). O número de unidades formadoras de colônia por mililitro (UFC/mL) foi determinado. Solução salina foi utilizada como controle negativo. Ambos, NaOCl a 2,5% e CHX a 2%, eliminaram E. faecalis após 30 s de contato. O ácido peracético reduziu a contagem bacteriana em 86% após 3 min e eliminou completamente E. faecalis após 10 min. Estes resultados permitem concluir que o ácido peracético a 1% é efetivo sobre E. faecalis, apesar de sua ação mais lenta quando comparado ao NaOCl a 2,5% e CHX a 2%.This study evaluated the in vitro antibacterial activity of conventional and experimental endodontic irrigants against Enterococcus faecalis. The following substances were evaluated by direct contact test: 2.5% sodium hypochlorite (NaOCl); 2% chlorhexidine (CHX); 1% peracetic acid. After different contact periods (30 s, 1, 3, and 10 min), a neutralizing agent was applied. Serial 10-fold dilutions were prepared and plated onto tryptic soy agar (TSA) and the number of colony-forming units per milliliter (CFU/mL) was determined. Sterile saline was used as a negative control. Both 2.5% NaOCl and 2% CHX eliminated E. faecalis after 30 s of contact. Peracetic acid reduced the bacterial counts by 86% after 3 min and completely eliminated E. faecalis after 10 min. These results allow us to conclude that 1% peracetic acid is effective against E. faecalis, despite its slower action compared with 2.5% NaOCl and 2% CHX.UNESP Department of Restorative DentistryUNESP Department of Restorative Dentistr
Spectrophotometric analysis of crown discoloration induced by MTA- and ZnOE-based sealers
Crown discoloration can be induced by root canal sealer remnants following root canal treatment. OBJECTIVE: The aim of this study was to evaluate chromatic alterations in human tooth crowns induced by a Mineral Trioxide Aggregate-based sealer (MTA Fillapex(®) and a commonly used ZnOE-based sealer (Roth-811). The tested null hypothesis was that the application of the materials did not induce clinically perceptible crown discoloration (Ho: CIE color difference ΔE<3.7). MATERIAL AND METHODS: Forty five fully developed, intact, mandibular third molars were sectioned 1 mm below the cemento-enamel junction. The pulp chambers were chemomechanically debrided via the cervical access. The specimens were randomly assigned into three groups Group 1: MTA Fillapex, Group 2: Roth 811, Group 3: Negative control (unfilled) and immersed in individually marked vials containing distilled water up to the cervix (37±1º C). The spectral reflectance lines were recorded by utilizing a UV-VIS spectrophotometer equipped with integration sphere in the visual spectrum at baseline, 1 week, 1 and 3 months after material placement. Data were transformed into values of the CIE L*a*b* color system and the corresponding ΔE values were calculated. Statistical analysis was performed using two-way mixed ANOVA models, at p=0.05 level of significance. RESULTS: A statistically significant increase in a* and b* chromatic parameters of the MTA Fillapex Group was measured. However, ΔE values did not exceed the human eye perceptibility threshold (set at ΔE<3.7) during the experimental period (ΔEt3=2.88). In Roth-811 Group, a statistically significant decrease in L* and a statistically significant increase in a* and b* chromatic parameters was measured, during all observation periods. Resultant ΔE values exceeded the human eye perceptibility threshold after 1 week (ΔEt1=5.65). CONCLUSIONS: Application of MTA Fillapex in tooth crowns resulted in minimal color alterations, while Roth 811 induced severe discoloration, in vitro. It could be suggested that, in terms of aesthetics, the use of MTA Fillapex appears to be favorable
Effect of final irrigation protocols on microhardness reduction and erosion of root canal dentin
Abstract This study aimed to evaluate the effect of final irrigation protocols on microhardness reduction and erosion of root canal dentin. Sixty root canals from mandibular incisors were instrumented and randomly divided into six groups (n = 10) according to the irrigant used: QMiX, 17% EDTA, 10% citric acid (CA), 1% peracetic acid (PA), 2.5% NaOCl (solution control), and distilled water (negative control). The chelating solutions were used to irrigate the canal followed by 2.5% NaOCl as a final flush. After the irrigation protocols, all specimens were rinsed with 10 mL of distilled water to remove any residue of the chemical solutions. Before and after the final irrigation protocols, dentin microhardness was measured with a Knoop indenter. Three indentations were made at 100 µm and 500 µm from the root canal lumen. Afterwards, the specimens were prepared for scanning electron microscopic analysis and the amount of dentin erosion was examined. Wilcoxon and Kruskal-Wallis tests were used to analyze the results with a significance level set at 5%. At 100 µm, all protocols significantly reduced dentin microhardness (p < .05), while at 500 µm, this effect was detected only in the EDTA and QMiX groups (p < .05). CA was the irrigant that caused more extensive erosion in dentinal tubules, followed by PA and EDTA. QMiX opened dentinal tubules, but did not cause dentin erosion. Results suggest that QMiX and 17% EDTA reduced dentin microhardness at a greater depth. Additionally, QMiX did not cause dentin erosion
Biological Tissue Response to a New Formulation of a Silicone Based Endodontic Sealer
Satisfactory biological behavior is a necessary requirement for clinical application of endodontic materials. In this study, the connective tissue responses to silicone (GuttaFlow 2), epoxy resin (AH Plus) and zinc oxide and eugenol (Endofill) based sealers were compared. Twelve Wistar rats had polyethylene tubes (four per animal) containing one of the tested sealers and empty tubes (negative control) implanted in their subcutaneous tissue. The tubes were randomly placed 2 cm from the spine and at least 2 cm apart from one another. Tissue samples with implants were processed for histological analysis after 7 or 60 days (n=6 animals per period). Inflammatory cells, fibrous condensation and abscess were scored according to their intensity. Friedman, followed by Dunn’s post hoc, was used to compare sealers. Differences between the two experimental periods were verified using Mann-Witney U test (p<0.05). At 7 days, most of the histological parameters showed no significant differences amongst groups. Endofill group scored higher than the others for giant cells (o<0.05) and promoted a greater number of samples presenting abscess formation. GuttaFlow 2 tended to show a less intense inflammatory infiltrate compared to the other materials. At 60 days, there were no significant differences between groups in most of the histological parameters evaluated. However, it was observed that Endofill scored higher for macrophages (p<0.05) compared to the control group, and GuttaFlow 2 tended to present lower scores than the others for neutrophils and abscess. GuttaFlow 2 showed proper biological behavior and should be considered adequate for clinical practice
