127 research outputs found
Liverpool telescope 2: a new robotic facility for rapid transient follow-up
The Liverpool Telescope is one of the world's premier facilities for time domain astronomy. The time domain landscape is set to radically change in the coming decade, with surveys such as LSST providing huge numbers of transient detections on a nightly basis; transient detections across the electromagnetic spectrum from other facilities such as SVOM, SKA and CTA; and the era of `multi-messenger astronomy', wherein events are detected via non-electromagnetic means, such as gravitational wave emission. We describe here our plans for Liverpool Telescope 2: a new robotic telescope designed to capitalise on this new era of time domain astronomy. LT2 will be a 4-metre class facility co-located with the LT at the Observatorio del Roque de Los Muchachos on the Canary island of La Palma. The telescope will be designed for extremely rapid response: the aim is that the telescope will take data within 30 seconds of the receipt of a trigger from another facility. The motivation for this is twofold: firstly it will make it a world-leading facility for the study of fast fading transients and explosive phenomena discovered at early times. Secondly, it will enable large-scale programmes of low-to-intermediate resolution spectral classification of transients to be performed with great efficiency. In the target-rich environment of the LSST era, minimising acquisition overheads will be key to maximising the science gains from any follow-up programme. The telescope will have a diverse instrument suite which is simultaneously mounted for automatic changes, but it is envisaged that the primary instrument will be an intermediate resolution, optical/infrared spectrograph for scientific exploitation of transients discovered with the next generation of synoptic survey facilities. In this paper we outline the core science drivers for the telescope, and the requirements for the optical and mechanical design
The low-virulent African swine fever virus (ASFV/NH/P68) induces enhanced expression and production of relevant regulatory cytokines (IFNα, TNFα and IL12p40) on porcine macrophages in comparison to the highly virulent ASFV/L60
The impact of infection by the low-virulent ASFV/NH/P68 (NHV) and the highly virulent ASFV/L60 (L60) isolates on porcine macrophages was assessed through the quantification of IFNα, TNFα, IL12p40, TGFβ and ASFV genes by real-time PCR at 2, 4 and 6 h post-infection. Increased IFNα, TNFα and IL12p40 expression was found in infection with NHV, in which expression of TGFβ was lower than in infection with L60. Principal component analysis showed a positive interaction of cytokines involved in cellular immune mechanisms, namely IFNα and IL12p40 in the NHV infection. Quantification by ELISA confirmed higher production of IFNα, TNFα and IL12p40 in the NHV-infected macrophages. Overall, our studies reinforce and clarify the effect of the NHV infection by targeting cellular and cellular-based immune responses relevant for pig survival against ASFV infection
Drosophila Nociceptors Mediate Larval Aversion to Dry Surface Environments Utilizing Both the Painless TRP Channel and the DEG/ENaC Subunit, PPK1
A subset of sensory neurons embedded within the Drosophila larval body wall have been characterized as high-threshold polymodal nociceptors capable of responding to noxious heat and noxious mechanical stimulation. They are also sensitized by UV-induced tissue damage leading to both thermal hyperalgesia and allodynia very similar to that observed in vertebrate nociceptors. We show that the class IV multiple-dendritic(mdIV) nociceptors are also required for a normal larval aversion to locomotion on to a dry surface environment. Drosophila melanogaster larvae are acutely susceptible to desiccation displaying a strong aversion to locomotion on dry surfaces severely limiting the distance of movement away from a moist food source. Transgenic inactivation of mdIV nociceptor neurons resulted in larvae moving inappropriately into regions of low humidity at the top of the vial reflected as an increased overall pupation height and larval desiccation. This larval lethal desiccation phenotype was not observed in wild-type controls and was completely suppressed by growth in conditions of high humidity. Transgenic hyperactivation of mdIV nociceptors caused a reciprocal hypersensitivity to dry surfaces resulting in drastically decreased pupation height but did not induce the writhing nocifensive response previously associated with mdIV nociceptor activation by noxious heat or harsh mechanical stimuli. Larvae carrying mutations in either the Drosophila TRP channel, Painless, or the degenerin/epithelial sodium channel subunit Pickpocket1(PPK1), both expressed in mdIV nociceptors, showed the same inappropriate increased pupation height and lethal desiccation observed with mdIV nociceptor inactivation. Larval aversion to dry surfaces appears to utilize the same or overlapping sensory transduction pathways activated by noxious heat and harsh mechanical stimulation but with strikingly different sensitivities and disparate physiological responses
Estimating genomic instability mediated by Alu retroelements in breast cancer
Alu-PCR is a relatively simple technique that can be used to investigate genomic instability in cancer. This technique allows identification of the loss, gain or amplification of gene sequences based on the analysis of segments between two Alu elements coupled with quantitative and qualitative analyses of the profiles obtained from tumor samples, surgical margins and blood. In this work, we used Alu-PCR to identify gene alterations in ten patients with invasive ductal breast cancer. Several deletions and insertions were identified, indicating genomic instability in the tumor and adjacent normal tissue. Although not associated with specific genes, the alterations, which involved chromosomal bands 1p36.23, 1q41, 11q14.3, 13q14.2, occurred in areas of well-known genomic instability in breast and other types of cancer. These results indicate the potential usefulness of Alu-PCR in identifying altered gene sequences in breast cancer. However, caution is required in its application since the Alu primer can produce non-specific amplification
Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock: 2008
SCOPUS: ar.jinfo:eu-repo/semantics/publishe
Functionalised magnetic nanoparticles for uranium adsorption with ultra-high capacity and selectivity
The removal of radioactive contaminants from the environment for safe and efficient waste disposal is a critical challenge, requiring the development of novel selective and high-capacity sequestering materials. In this paper the design of superparamagnetic iron oxide nanoparticles (SPIONs) as highly efficient magnetic-sorbent structures for uranium (U(VI)) separation is described. The nanosorbent was developed by surface functionalisation of single crystalline magnetite (Fe3O4) nanoparticles with a phosphate-based complex coating. This new design allowed for the development of a magnetically separable ultra-effective sorbent, with a measured U(VI) sorption capacity of ∼2333 mg U per g Fe (1690 mg U per g Fe3O4 NP), significantly higher than everything previously reported. Based on TEM analysis, it is proposed that these properties are the result of a multi-layer ligand structure, which enables a high degree of U-incorporation compared to conventional surface-ligand systems. Moreover, the phosphate-NP construct ((PO)x-Fe3O4) shows exceptionally high specificity for the sequestration of U(VI) in solution at pH 7. Adsorption tests in the presence of competing ions, such as Sr(II), Ca(II) and Mg(II), showed high selectivity of the nanoparticles for U(VI) and extremely rapid kinetics of contaminant removal from solution, with the total amount of uranyl ions being removed after only 60 seconds of contact with the NPs. The results presented in this paper highlight the potential of such a phosphate-functionalised magnetic nanosorbent as a highly effective material for the remediation of U(VI) from contaminated water and industrial scenarios
Pyridostigmine in Pediatric Intestinal Pseudo-obstruction: Case Report of a 2-year Old Girl and Literature Review.
Pediatric chronic intestinal pseudo-obstruction is a rare disorder characterized by a severe impairment of gastrointestinal motility leading to intestinal obstruction symptoms in the absence of mechanical causes. The diagnosis is usually clinical and diagnostic work is usually aimed to rule out mechanical obstruction and to identify any underlying diseases. Treatment is challenging and requires a multidisciplinary effort. In this manuscript we describe the youngest child successfully treated with the orally administrable, longacting, reversible anti-cholinesterase drug, pyridostigmine. Like other drugs belonging to cholinesterase inhibitors, pyridostigmine enhances gut motility by increasing acetylcholine availability in the enteric nervous system and neuro-muscular junctions. Based on the direct evidence from the reported case, we reviewed the current literature on the use of pyridostigmine in severe pediatric dysmotility focusing on intestinal pseudo-obstruction. The overall data emerged from the few published studies suggest that pyridostigmine is an effective and usually well tolerated therapeutic options for patients with intestinal pseudo-obstruction. More specifically, the main results obtained by pyridostigmine included marked reduction of abdominal distension, reduced need of parenteral nutrition, and improvement of oral feeding. The present case and review on pyridostigmine pave the way for eagerly awaited future randomized controlled studies testing the efficacy of cholinesterase inhibitors in pediatric severe gut dysmotility
Advances in the technology of automated, tidal, and continuous flow peritoneal dialysis
Automated peritoneal dialysis (APD) has undergone substantial growth in recent years because of an increased demand for higher doses of peritoneal dialysis (PD) treatment and a need to improve quality of life for patients. The evolution of this treatment is closely linked with the development of new automatic machines and with recent advances in prescription and monitoring of PD treatment. In the present article, we describe the characteristics of the new generation of APD cyclers with particular regard to adequacy targets and safety. There is renewed interest in continuous-flow peritoneal dialysis (CFPD), because of a belief that new peritoneal access technologies will make the success of this modality a possibility. In the CFPD technique, a certain amount of fluid is constantly present in the abdomen, and constant inflow and outflow are maintained without interruption thanks to paired indwelling catheters. The PD solution is used either in a single pass or in a recirculation loop with a regeneration systems (sorbent cartridge or dialyzer)
Rational choice of peritoneal dialysis catheter
The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to widespread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the predominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters
- …
