169 research outputs found
Radiogenic and muon-induced backgrounds in the LUX dark matter detector
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is
(2.6±0.2stat±0.4sys)×10-3
events
keVee-1kg-1day-1
in a 118 kg fiducial volume. The observed background rate is
(3.6±0.4stat)×10-3
events
keVee-1kg-1day-1
, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of U~1.6~mBq/kg, U~0.09~mBq/kg, Th~~mBq/kg, Th~~mBq/kg, K~0.54~mBq/kg, and Co~0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of (stat)(sys) counts
LUX-ZEPLIN (LZ) Technical Design Report
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters
Relationship between epistasis and aggressiveness in resistance of pepper (Capsicum annuum L.) to Phytophthora nicotianae
This study evaluated the types of gene action governing the inheritance of resistance to Phytophthora nicotianae necrosis in populations derived from two crosses involving two susceptible (Beldi and Nabeul II) and one resistant (CM334) cultivars of pepper (Capsicum annuum L.). Populations, composed of Pr, Ps, F1 , F 2 , BC 1 Pr, and BC 1 Ps generations, were inoculated with six P. nicotianae isolates. Generation means analysis indicated that an additive-dominance model was appropriate for P. nicotianae isolates Pn Ko1 , Pn Ko2 and Pn Kr1 , which showed low aggressiveness in the two crosses. For the more aggressive isolates Pn Bz1 , Pn Bz2 and Pn Kr2 , epistasis was an integral component of resistance in the two crosses. The presence of epistasis in the resistance of pepper to P. nicotianae was dependent on the level of aggressiveness of the isolates. Selection in pepper with less aggressive isolates was efficient, but not with more aggressive isolates; on the other hand, selection with more aggressive isolates was more stable. The minimum number of genes controlling resistance was estimated at up to 2.71. In the majority of cases, the additive variance was significant and greater than the environmental and dominance variance
Complications related to deep venous thrombosis prophylaxis in trauma: a systematic review of the literature
Deep venous thrombosis prophylaxis is essential to the appropriate management of multisystem trauma patients. Without thromboprophylaxis, the rate of venous thrombosis and subsequent pulmonary embolism is substantial. Three prophylactic modalities are common: pharmacologic anticoagulation, mechanical compression devices, and inferior vena cava filtration. A systematic review was completed using PRISMA guidelines to evaluate the potential complications of DVT prophylactic options. Level one evidence currently supports the use of low molecular weight heparins for thromboprophylaxis in the trauma patient. Unfortunately, multiple techniques are not infrequently required for complex multisystem trauma patients. Each modality has potential complications. The risks of heparin include bleeding and heparin induced thrombocytopenia. Mechanical compression devices can result in local soft tissue injury, bleeding and patient non-compliance. Inferior vena cava filters migrate, cause inferior vena cava occlusion, and penetrate the vessel wall. While the use of these techniques can be life saving, they must be appropriately utilized
Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. These results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils
Fast and flexible analysis of direct dark matter search data with machine learning
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture nonlinear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs, such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable
Effective field theory analysis of the first LUX dark matter search
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6×10-46 cm2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4×104 kg·day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass
Improved Modeling of β Electronic Recoils in Liquid Xenon Using LUX Calibration Data
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the decays of H and C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction
Investigation of background electron emission in the LUX detector
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments
- …
