2 research outputs found
Repurposing anti-mesothelin CAR-NK immunotherapy against colorectal cancer
Abstract Background Colorectal cancer (CRC) is the third most common cancer worldwide, with highly variable prognosis and response to treatment. A large subset of patients does not respond to standard treatments or develops resistance. As an alternative, adoptive immunotherapy based on chimeric antigen receptor (CAR)-transduced immune cells has been proposed, however with significant adverse events. We therefore evaluated alternative CAR targets already tested in other tumour types and employed the natural killer cell line NK-92 for CAR transduction because of its more favourable toxicity profile. Methods As an alternative antigen, we considered mesothelin (MSLN), the most represented target in CAR-based clinical studies for solid tumours. MSLN RNA expression was analysed in large series of CRC tumours (n = 640) and cell lines (n = 150), to evaluate its distribution and to identify MSLN-overexpressing models. NK-92 cells were transduced with anti-MSLN CAR, and subsequently sorted and cloned. Activity of CAR-NK-92 cells against target-expressing ovarian and CRC cells was assessed in vitro and in vivo. Statistical significance of efficacy was evaluated by t-test and log-rank test. Results Large-scale expression analysis highlighted that about 10% of CRCs overexpress MSLN at levels comparable to those of ovarian cancer, a typical target of MSLN-CAR-based therapy. Intriguingly, MSLN overexpression is more frequent in poor prognosis and KRAS/BRAF-mutant CRC. Lentiviral transduction of NK-92 cells with the MSLN-CAR, followed by sorting and cloning, led to the identification of one clone, MSLN.CAR.NK-92.cl45, stably expressing the CAR and retaining the NK phenotype. As expected, the clone demonstrated significant in vitro and in vivo activity against ovarian cancer cells. When repurposed against models of CRC expressing high MSLN levels, it displayed comparable efficacy, both in vitro and in vivo. Specificity of the clone was confirmed by the absence of activity on control models with low or absent MSLN. Conclusions Our results provide preclinical evidence that a subset of colorectal cancers expressing high mesothelin levels can be effectively targeted by MSLN-CAR-based immunotherapy. The potential therapeutic impact of these findings is enhanced by the fact that frequently MSLN-overexpressing CRCs display worse prognosis and resistance to standard care
Characterization of an organic semiconductor diode for dosimetry in radiotherapy
© 2020 American Association of Physicists in Medicine Purpose: The development of novel detectors for dosimetry in advanced radiotherapy modalities requires materials that have a water equivalent response to ionizing radiation such that characterization of radiation beams can be performed without the need for complex calibration procedures and correction factors. Organic semiconductors are potentially an ideal technology in fabricating devices for dosimetry due to tissue equivalence, mechanical flexibility, and relatively cheap manufacturing cost. The response of a commercial organic photodetector (OPD), coupled to a plastic scintillator, to ionizing radiation from a linear accelerator and orthovoltage x-ray tube has been characterized to assess its potential as a dosimeter for radiotherapy. The radiation hardness of the OPD has also been investigated to demonstrate its longevity for such applications. Methods: Radiation hardness measurements were achieved by observing the response of the OPD to the visible spectrum and 70 keV x rays after pre-exposure to 40 kGy of ionizing radiation. The response of a preirradiated OPD to 6-MV photons from a linear accelerator in reference conditions was compared to a nonirradiated OPD with respect to direct and indirect (RP400 plastic scintillator) detection mechanisms. Dose rate dependence of the OPD was measured by varying the surface-to-source distance between 90 and 300 cm. Energy dependence was characterized from 29.5 to 129 keV with an x-ray tube. The percentage depth dose (PDD) curves were measured from 0.5 to 20 cm and compared to an ionization chamber. Results: The OPD sensitivity to visible light showed substantial degradation of the broad 450 to 600 nm peak from the donor after irradiation to 40 kGy. After irradiation, the spectral shape has a dominant absorbance peak at 370 nm, as the acceptor better withstood radiation damage. Its response to x rays stabilized to 30% after 35 kGy, with a 0.5% difference between 770 Gy increments. The OPD exhibited reproducible detection of ionizing radiation when coupled with a scintillator. Indirect detection showed a linear response from 25 to 500 cGy and constant response to dose rates from 0.31 Gy/pulse to 3.4 × 10−4 Gy/pulse. However, without the scintillator, response increased by 100% at low dose rates. Energy independence between 100 keV and 1.2 MeV advocates their use as a dosimeter without beam correction factors. A dependence on the scintillator thickness used during a comparison of the PDD to the ionizing chamber was identified. A 1-mm-thick scintillator coupled with the OPD demonstrated the best agreement of ± 3%. Conclusions: The response of OPDs to ionizing radiation has been characterized, showing promising use as a dosimeter when coupled with a plastic scintillator. The mechanisms of charge transport and trapping within organic materials varies for visible and ionizing radiation, due to differing properties for direct and indirect detection mechanisms and observing a substantial decrease in sensitivity to the visible spectrum after 40 kGy. This study proved that OPDs produce a stable response to 6-MV photons, and with a deeper understanding of the charge transport mechanisms due to exposure to ionizing radiation, they are promising candidates as the first flexible, water equivalent, real-time dosimeter
