3,807 research outputs found

    Effectiveness of rotary or manual techniques for removing a 6-year-old filling material

    Get PDF
    The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill) , and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p&gt;0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.O objetivo deste estudo foi avaliar a efetividade da instrumentação manual e rotatória na remoção de material obturador de canais radiculares de raízes palatinas de molares superiores humanos, em dois períodos de tempo. Vinte e quatro raízes foram instrumentadas e obturadas com guta-percha, cimento de óxido de zinco e eugenol e armazenadas em solução salina durante 6 anos. Outras 24 raízes foram tratadas da mesma maneira e armazenadas por uma semana. Os canais radiculares foram retratados usando limas manuais ou instrumentos rotatórios do Sistema ProTaper Universal. Radiografias periapicais foram feitas para mensurar a quantidade de material remanescente. Posteriormente as raízes foram clivadas e imagens microscópicas obtidas a partir de um microscópio clínico operatório foram digitalizadas. As imagens foram avaliadas através do software Autocad 2004 e área de material obturador remanescente foi mensurada. A Análise da Variância (Two-way) e o Teste T demonstraram não haver diferenças estatisticamente significantes entre a técnica manual e rotatória na remoção de material obturador. O terço apical mostrou a maior percentagem de remanescentes de material obturador, na análise radiográfica e microscópica quando comparado com os outros terços radiculares. Todos os canais revelaram resíduos de material obturador após o retratamento endodôntico. A análise microscópica foi mais efetiva do que a radiográfica na detecção de remanescente de obturação do canal radicular

    An in vitro radiographic evaluation of the accuracy of Apex and iPex electronic apex locator

    Get PDF
    The aim of this study was to evaluate in vivo the clinical applicability of two electronic apex locators (EALs) - Apex (Septodont) and iPex (NSK) - in different groups of human teeth by using radiography. The working lengths (WLs) of 100 root canals were determined electonically. The EAL to be used first was chosen randomly and a K-file was inserted into the root canal until the EAL display indicated the location of the apical constriction (0 mm). The K-file was fixed to the tooth and a periapical radiograph was taken using a radiographic film holder. The K-file was removed and the WL was measured. The same procedure was repeated using the other EAL. Radiographs were examined with the aid of a ligth-box with lens of x4 magnification by two blinded experienced endodontics. The distance between the file tip and the root apex was recorded as follows: (A) + 1 to 0 mm, (B) -0.1 to 0.5 mm, (C) -0.6 to 1 mm, (D)-1.1 to 1.5 mm, and (E) -1.6 mm or greater. For statistical purposes, these scores were divided into 2 subgroups according to the radiographic apex: acceptable (B, C and D) and non-acceptable (A and E). Statistically significant differences were not found between the results of Apex and iPex in terms of acceptable and non-acceptable measurements (P>0.05). Apex and iPex EALs provided reliable measurements for WL determination for endodontic therapy

    J-PLUS: A wide-field multi-band study of the M15 globular cluster. Evidence of multiple stellar populations in the RGB

    Full text link
    The Javalambre Photometric Local Universe Survey (J-PLUS) provides wide field-of-view images in 12 narrow, intermediate and broad-band filters optimized for stellar photometry. Here we have applied J-PLUS data for the first time for the study of Galactic GCs using science verification data obtained for the very metal-poor GC M\,15. Our J-PLUS data provide low-resolution spectral energy distributions covering the near-UV to the near-IR, allowing us to search for MPs based on pseudo-spectral fitting diagnostics. J-PLUS CMDs are found to be particularly useful to search for splits in the sequences formed by the upper red giant branch (RGB) and asymptotic giant branch (AGB) stars. We interpret these split sequences as evidence for the presence of MPs. This demonstrates that the J-PLUS survey will have sufficient spatial coverage and spectral resolution to perform a large statistical study of GCs through multi-band photometry in the coming years.Comment: 11 pages, 11 figures. Accepted for publication @ A&

    Redução de ruídos em motores elétricos

    Get PDF
    Dissertação (mestrado) - Universidade Federal de Santa Catanrina, Centro Tecnológico. Programa de Pós- Graduação em Engenharia Mecânica

    Efeitos da perda de massa na nucleossíntese de estrelas AGB

    Get PDF
    Neste trabalho construímos um modelo sintético de evolução de estrelas AGB. Para investigar as incertezas na parametrização dos ventos, usamos três leis de perda de massa. Os parâmetros de dragagem foram calibrados através da Função de Luminosidade de Estrelas Carbonadas para a Grande e Pequena Nuvens de Magalhães. O hot bottom burning foi calibrado através das abundâncias em nebulosas planetárias. Além disto, para verificar a consistência das calibrações, empregamos a Relação Massa Inicial-Massa Final e a Distribuição de Massa de Anãs Brancas. Calculamos yields finais de maneira consistente com os vínculos observacionais, para perdas de massa diferentes. A variabilidade de yields que encontramos indica que a perda de massa durante a fase AGB representa uma das fontes de maior incerteza na nucleossíntese de estrelas AGB

    A DIMENSÃO POLÍTICO/EDUCATIVA DAS OPÇÕES ESTÉTICAS NOS MANIFESTOS FUNDADORES DO CINEMA COMO ARTE

    Get PDF
    Este texto apresenta uma reflexão sobre como o cinema concebeu, originalmente, o papel educativo que poderia vir a desempenhar na sociedade, pelo ponto de vista dos primeiros realizadores. Argumenta-se que o caráter educativo do cinema estava presente, explícita e/ou implicitamente, entre os objetivos de alguns de seus mais importantes criadores. Para tanto, tomam-se como fonte textos de lançamento de movimentos estéticos cinematográficos, surgidos nas primeiras décadas da invenção do cinematógrafo, que tinham como objetivo apresentar propostas para o que deveria ser a nova arte

    Criminologia midiática e corrupção: escandalização e seletividade da imprensa

    Get PDF
    Tendo em vista que a Criminologia é uma ciência interdisciplinar que se pauta na experiência da observação, indaga-se sobre a relação da criminologia midiática e corrupção, a fim de se compreender o enfoque que os meios de comunicação dão à cobertura midiática brasileira e constatar se são aplicados critérios de seletividade iníquo. Para tanto, é necessário compreender a funcionalidade da criminologia midiática, como ela se concatena com a corrupção e a maneira que a cobertura midiática brasileira aborda a corrupção. Realiza-se, então, uma pesquisa empírica a respeito de quando e como os veículos de comunicação retrataram a corrupção nos períodos antecedentes às eleições à Presidência da República de 2010 e do ano de 2014, bem como retratar o “escândalo” da Operação Lava Jato e a sua operacionalização nos grandes meios de comunicação. Diante disso, verifica-se que os meios de comunicação adotam um critério seletivo, sectário e pragmático referente às notícias que envolvam tema sobre corrupção e, principalmente, como esse comportamento se intensifica ao elencar quais notícias sobre corrupção serão objetos de escandalização e abordagem massiva e repetitiva. O que impõe a constatação dos grandes meios de informação, por motivos particulares, estão exercendo o jornalismo como um instrumento de modulação da percepção sobre a corrupção no Brasil, sem o compromisso com a imparcialidade, o que deveria respaldar o trabalho de todo e qualquer jornalista
    corecore