550 research outputs found

    Cone beam computed tomography after round window vibroplasty. do the radiological findings match the auditory outcome?

    Get PDF
    Conclusion: The CBCT imaging technique has proved to be reliable for assessing the appropriate positioning of the FMT in the round window niche. However, when considering specific imaging parameters, such as lack of bony contacts and appropriate inferior support, they would not seem essential for achieving a satisfactory functional outcome. Objectives: To evaluate the value of some imaging parameters derived from a Cone Beam Computed Tomography of the temporal bone for predicting a good functional outcome after Round Window Vibroplasty (RW-VP). Method: A CBCT imaging has been carried out at certain time after RW-VP surgery in a homogenous group of patients who presented with a mixed-type hearing loss after open tympanoplasty for a cholesteatoma. Three arbitrary radiological parameters have been considered for the purpose: the FMT/RW membrane contact; eventual FMT bony contacts; appropriatmess of inferior FMT support. The audiological assessment has taken into consideration the PTA4 (500-4000 Hertz), the PTA2 (125.250 Hertz), the WRS in quiet and in noise (SNR=+10). A comparison between the unaided and the RW-VP aided condition has been performed

    Results of medium seventeen years' follow-up after laparoscopic choledochotomy for ductal stones

    Get PDF
    INTRODUCTION: In a previously published article the authors reported the long-term follow-up results in 138 consecutive patients with gallstones and common bile duct (CBD) stones who underwent laparoscopic transverse choledochotomy (TC) with T-tube biliary drainage and laparoscopic cholecystectomy (LC). Aim of this study is to evaluate the results at up to 23 years of follow-up in the same series. METHODS: One hundred twenty-one patients are the object of the present study. Patients were evaluated by clinical visit, blood assay, and abdominal ultrasound. Symptomatic patients underwent cholangio-MRI, followed by endoscopic retrograde cholangiopancreatography (ERCP) as required. RESULTS: Out of 121 patients, 61 elderly patients died from unrelated causes. Fourteen patients were lost to follow-up. In the 46 remaining patients, ductal stone recurrence occurred in one case (2,1%) successfully managed by ERCP with endoscopic sphincterotomy. At a mean follow-up of 17.1 years no other patients showed signs of bile stasis and no patient showed any imaging evidence of CBD stricture at the site of choledochotomy. CONCLUSIONS: Laparoscopic transverse choledochotomy with routine T-tube biliary drainage during LC has proven to be safe and effective at up to 23 years of follow-up, with no evidence of CBD stricture when the procedure is performed with a correct technique

    Is contrast-enhanced US alternative to spiral CT in the assessment of treatment outcome of radiofrequency ablation in hepatocellular carcinoma?

    Get PDF
    Purpose: The present study was conducted to assess the efficacy of contrast-enhanced ultrasound with low mechanical index in evaluating the response of percutaneous radiofrequency ablation treatment of hepatocellular carcinoma by comparing it with 4-row spiral computed tomography. Materials and Methods: 100 consecutive patients (65 men and 35 women; age range: 62 – 76 years) with solitary hepatocellular carcinomas (mean lesion diameter: 3.7cm± 1.1cm SD) underwent internally cooled radiofrequency ablation. Therapeutic response was evaluated at one month after the treatment with triple-phasic contrast-enhanced spiral CT and low-mechanical index contrast-enhanced ultrasound following bolus injection of 2.4 ml of Sonovue (Bracco, Milan). 60 out of 100 patients were followed up for another 3 months. Contrast-enhanced sonographic studies were reviewed by two blinded radiologists in consensus. Sensitivity, specificity, NPV and PPV of contrast-enhanced ultrasound examination were determined. Results: After treatment, contrast-enhanced ultrasound identified persistent signal enhancement in 24 patients (24%), whereas no intratumoral enhancement was detected in the remaining 76 patients (76%). Using CT imaging as gold standard, the sensitivity, specificity, NPV, and PPV of contrast enhanced ultrasound were 92.3% (95% CI = 75.9 – 97.9%), 100% (95% CI = 95.2 – 100%), 97.4% (95% CI = 91.1 – 99.3%), and 100% (95% CI = 86.2 – 100%). Conclusion: Contrast-enhanced ultrasound with low mechanical index using Sonovue is a feasible tool in evaluating the response of hepatocellular carcinoma to radiofrequency ablation. Accuracy is comparable to 4-row spiral CT

    Towards the Energy Transition of the Building Stock with BIPV: Innovations, Gaps and Potential Steps for a Widespread Use of Multifunctional PV Components in the Building Envelope

    Get PDF
    The scenario that emerges from scientific research on the use of BIPV systems in architecture shows that photovoltaic technologies and systems have reached a significant development in production and installation, becoming a strategic approach in the field of energy efficiency and enabling a progressive decarbonisation of the building stock. Still, knowledge and methods of architectural integration are not fully developed, especially in Italy. The present paper reports the results of a research activity that, systematising the main criteria and indicators for assessing the integrability of BIPVs in architecture, has led to the development of BIPV Product and Case Study Catalogues that define an up-to-date state of the art on aspects of design and technological innovation using BIPV systems and components. Catalogues have been created with the objective of contributing to the growth of knowledge on the most up-to-date methods of design by implementing a ‘technology transfer’ from good practice, in which photovoltaic systems are an integral part of the design concept and construction techniques of the architecture. The analysis related to the production of BIPV systems and components and their application in architectural projects allows one to highlight the main critical factors in the diffusion throughout the country and to identify the main research demand arising from the specific national situation

    Neutralino-Nucleon Cross Section and Charge and Colour Breaking Constraints

    Full text link
    We compute the neutralino-nucleon cross section in several supersymmetric scenarios, taking into account all kind of constraints. In particular, the constraints that the absence of dangerous charge and colour breaking minima imposes on the parameter space are studied in detail. In addition, the most recent experimental constraints, such as the lower bound on the Higgs mass, the bsγb\to s\gamma branching ratio, and the muon g2g-2 are considered. The astrophysical bounds on the dark matter density are also imposed on the theoretical computation of the relic neutralino density, assuming thermal production. This computation is relevant for the theoretical analysis of the direct detection of dark matter in current experiments. We consider first the supergravity scenario with universal soft terms and GUT scale. In this scenario the charge and colour breaking constraints turn out to be quite important, and \tan\beta\lsim 20 is forbidden. Larger values of tanβ\tan\beta can also be forbidden, depending on the value of the trilinear parameter AA. Finally, we study supergravity scenarios with an intermediate scale, and also with non-universal scalar and gaugino masses where the cross section can be very large.Comment: Final version to appear in JHE

    Multidrug resistant pulmonary tuberculosis treatment regimens and patient outcomes: an individual patient data meta-analysis of 9,153 patients.

    Get PDF
    Treatment of multidrug resistant tuberculosis (MDR-TB) is lengthy, toxic, expensive, and has generally poor outcomes. We undertook an individual patient data meta-analysis to assess the impact on outcomes of the type, number, and duration of drugs used to treat MDR-TB

    Physics-Informed Extreme Theory of Functional Connections Applied to Data-Driven Parameters Discovery of Epidemiological Compartmental Models

    Full text link
    In this work we apply a novel, accurate, fast, and robust physics-informed neural network framework for data-driven parameters discovery of problems modeled via parametric ordinary differential equations (ODEs) called the Extreme Theory of Functional Connections (X-TFC). The proposed method merges two recently developed frameworks for solving problems involving parametric DEs, 1) the Theory of Functional Connections (TFC) and 2) the Physics-Informed Neural Networks (PINN). In particular, this work focuses on the capability of X-TFC in solving inverse problems to estimate the parameters governing the epidemiological compartmental models via a deterministic approach. The epidemiological compartmental models treated in this work are Susceptible-Infectious-Recovered (SIR), Susceptible-Exposed-Infectious-Recovered (SEIR), and Susceptible-Exposed-Infectious-Recovered-Susceptible (SEIR). The results show the low computational times, the high accuracy and effectiveness of the X-TFC method in performing data-driven parameters discovery of systems modeled via parametric ODEs using unperturbed and perturbed data
    corecore