10 research outputs found
Bilateral Bennett's fracture: A case report
Bennet's fracture represents one of the most common injuries of the hand district, involving the base of the thumb, and it is affects children and elderly patients the most. The fracture is caused by direct axial trauma to a partially flexed first metacarpal and it is always intra-articular: the fracture line separates the palmar ulnar aspect of the first metacarpal base from the remaining first metacarpal. The fracture pattern is such that the first metacarpal shaft moves dorsally, proximally, and radially due to the pull of the abductor pollicis longus, extensor pollicis longus, extensor pollicis brevis, and the adductor pollicis brevis, which remain attached to the fracture fragment. The surgical treatment consists of closed reduction with percutaneous pinning or open reduction with either pins or interfragmentary screws. The decision to treat these fractures with either open reduction or closed reduction is still a matter of debate. To the best of our knowledge, there are no cases of bilateral Bennett's fracture reported in literature. The aim of this paper is to present a rare case of bilateral Bennet's fracture, the decision of two different treatments, and the good clinical outcomes
Study of a constrained finite element elbow prosthesis: the influence of the implant placement
BackgroundThe functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions.Materials and methodsBy means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by +/- 3 degrees.ResultsThe greatest von Mises stress state in the bone component for the 90 degrees working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0 degrees and 145 degrees showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90 degrees (- 3 degrees in the sagittal plane, 0 degrees in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement.ConclusionThe areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90 degrees. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.Level of evidence:
Adoption of blockchain as a step forward in orthopedic practice
Blockchain technology has gained popularity since the invention of Bitcoin in 2008. It offers a decentralized and secure system for managing and protecting data. In the healthcare sector, where data protection and patient privacy are crucial, blockchain has the potential to revolutionize various aspects, including patient data management, orthopedic registries, medical imaging, research data, and the integration of Internet of Things (IoT) devices. This manuscript explores the applications of blockchain in orthopedics and highlights its benefits. Furthermore, the combination of blockchain with artificial intelligence (AI), machine learning, and deep learning can enable more accurate diagnoses and treatment recommendations. AI algorithms can learn from large datasets stored on the blockchain, leading to advancements in automated clinical decision-making. Overall, blockchain technology has the potential to enhance data security, interoperability, and collaboration in orthopedics. While there are challenges to overcome, such as adoption barriers and data sharing willingness, the benefits offered by blockchain make it a promising innovation for the field
Indications and limitations of the fixator TGF "Gex-Fix" in proximal end humeral fractures
The incidence of fractures of the humerus has increased exponentially in recent years. The most used classifications for humerus fracture are morphological (Neer), biological (AO/ASIF) and descriptive (Hertel). The types of surgical treatment for humerus fracture include prosthetic replacement and synthesis using different devices, including the Tension Guide Fixator (TGF), Gex-Fix. External fixation for displaced proximal humeral fractures avoids dissection and soft tissue stripping and has been reported by some authors to be associated with higher union rates, a lower incidence of avascular necrosis, less scarring of the scapulohumeral interface, and faster rehabilitation compared with open reduction and internal fixation. Other authors have reported that external fixation does not ensure acceptable reduction and fracture stability, particularly in patients with osteoporosis. The external fixation technique involves the introduction of Steinmann's pin to keep manual reduction, the introduction of two K-wires in the humeral head, the removal of the Steinmann's pin, and the introduction of two fiches on the humeral shaft. Hub connectors are mounted on the wires and on the chips to connect the outer bar and tensioning system. A total of 84 patients aged 42-84 years with proximal end humeral fractures (66% had two-part fractures) were treated with Fixator TGF in this study from December 2007 to June 2012. The postoperative recovery was earlier and the active-assisted motion was less painful than has been reported with other surgical techniques. The TGF was removed without anaesthesia at the outpatient clinic at a mean of 7 weeks (range 5-8 weeks) after surgery, and there was no loss of reduction or secondary displacement after removal. These results, after five years of experience, confirm that the best indication for this fixator is two- or three-part fractures because the device enables early active mobilisation. The limitations of this fixator are evident in fractures in which closed reduction is not possible and in three-part fractures with varus displacement because the TGF has less stability than other systems, such as the plate or cage. The short learning curve, reduced surgical time and risk, and low cost encourage the use of this technique
The indirect effect of a focus group for psoriatic patients on their caregivers
Psoriasis is a chronic skin disease involving not only epidermic damages but also psychological distress for patients and their family caregivers. Little is known about the effects of a psychological support for psoriatic patients on their caregivers’ well-being. The goal of the present study was to investigate the indirect effects of the participation in a dynamic focus group reserved for psoriatic patients on their caregivers in terms of quality of life. The study involved 52 psoriatic patients and 41 family caregivers. Patients’ wellbeing was assessed using the dermatology quality of life index, hospital anxiety and depression scale. The impact of the disease on caregivers was assessed using the family dermatology life quality index (FDLQI). Data were analyzed with linear mixed models. The caregivers of psoriatic patients involved in the psychodynamic focus group reported levels of FDLQI that decreased over time, therefore showing an improvement in their quality of life in relation to the pathology of their relatives; the caregivers of patients who did not participate in the psychodynamic focus group, instead, had levels of FDLQI that were stable over time. The results provide preliminary evidence that the group setting of the Psychodynamic Focus Group may alleviate the negative impact of psychosomatic disease on the caregivers.</jats:p
Le infezioni tubercolari dell’apparato locomotore
Gli AA dopo aver presentato i dati epidemiologici più importanti
della TBC osteoarticolare, si soffermano sulla fisiopatologia, il
quadro clinico e radiografico delle localizzazioni più frequenti
sottolineando i segni clinici e radiografici tipici di queste lesioni e
l’importanza della RM, specie se eseguita con mezzo di contrasto,
nella diagnosi precoce della malattia.
Vengono inoltre presi in considerazione gli aspetti evolutivi della
malattia sia prima che dopo l’introduzione dei farmaci antitubercolari,
la terapia medica ed il trattamento incruento e chirurgico
delle varie forme.
Gli AA concludono che la TBC è una malattia purtroppo sempre
di attualità contrariamente a quanto si pensava alla fine degli
anni settanta quando si diffuse la convinzione che essa fosse stata
debellata.
Importante è fare la diagnosi il più precocemente possibile, perché
l’inizio precoce della terapia medica associata al trattamento ortopedico
può assicurare la guarigione nel 90% de
Bilateral Scaphoid Fractures: A Systematic Literature Review
Bilateral scaphoid fractures are rare lesions, warranting a review to synthesize current knowledge, identify gaps, and suggest research directions. Two authors, adhering to PRISMA guidelines, in January 2024 identified 16 case reports (1976–2023). Data extraction included demographics, injury mechanisms, associated injuries, fracture sites, treatments, and outcomes. Among 121 initial outcomes, 16 articles met the criteria, predominantly affecting young people (93.75% males, mean age 22 years). High-energy traumas (75%) often caused associated wrist injuries (68.75%). Most fractures required surgical intervention (68.75%), primarily headless compression screws. Bilateral scaphoid fractures, which are rare but associated with high-energy traumas, commonly involve wrist injuries. Surgical management is often necessary, yielding better outcomes with fewer complications. Further research is essential to understand the epidemiology, optimal management, and long-term results. Early diagnosis and appropriate treatment are crucial for preventing complications and ensuring favorable patient outcomes
