81 research outputs found

    A Precision Surgery Framework for Lung Resection: Robotic, Video-Assisted, and Open Segmentectomy

    Get PDF
    Objectives: To evaluate outcomes of patients undergoing lung segmentectomy using open thoracotomy, Video-Assisted Thoracoscopic Surgery (VATS), or Robotic-Assisted Thoracoscopic Surgery (RATS) approaches. Methods: A total of 157 patients (mean age: 68.7 years; 58% male) who underwent lung segmentectomy from 2015 to 2024 at the Thoracic Surgery of Siena were retrospectively enrolled and divided into groups based on the surgical approach: thoracotomy (n = 60), VATS (n = 58), and RATS (n = 39). No significant differences were observed between groups in terms of age, gender, or tumor stage. Peri-operative outcomes, and, in patients with non-small cell lung cancer (NSCLC, n = 104), long-term outcomes, were analyzed. Group comparisons were conducted using Kruskal–Wallis, Dunn’s test, Chi-squared, or Fisher’s exact test and Kaplan–Meier analysis with log-rank test. Results: Conversion rate was 13% and 0% for VATS and RATS, respectively (p = 0.005). Pleural effusion on first post-operative day was lower in RATS than VATS (p = 0.0006) and open (p < 0.0001). The maximum Visual Analogue Scale (VAS) value recorded was lower in RATS than open (p = 0.016) and VATS (p = 0.013). Surgery time was longer for RATS than open (p = 0.001) and VATS (p = 0.013). No differences were found in hospital stay and post-operative complications. In patients with NSCLC, the median follow-up was 25 months. The 90-day mortality rate was 9.5% in thoracotomy, 0% in VATS and RATS (p = 0.05). The 1- and 2-year overall survival was higher in VATS and RATS groups than thoracotomy (p = 0.001 and p = 0.040, respectively). The number of harvested lymph nodes was larger in the open group (p = 0.010), while a higher number of stations were harvested in RATS and open than VATS (p = 0.001). No differences were found in local recurrence (p= 0.08). Conclusions: RATS segmentectomy ensures a lower conversion rate, less post-operative pain, reduced daily pleural effusion, and a greater number of harvested lymph node stations compared to VATS, providing comparable peri-operative outcomes. RATS and VATS segmentectomy offer an advantage over the open approach in short- and long-term survival

    Echinococcus vogeli Infection in a Hunter, French Guiana

    Get PDF
    Echinococcus vogeli infection in a hunter from the rain forest of French Guiana was confirmed by imaging and mitochondrial DNA sequence analysis. Serologic examination showed typical patterns for both alveolar and cystic echinococcosis. Polycystic echinococcis caused by E. vogeli may be an emerging parasitic disease in Central and South America

    Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Get PDF
    The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 μ\mum thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 310153 \cdot 10^{15} neq/cm2^2. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations

    Failure to detect Plasmodium vivax in West and Central Africa by PCR species typing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p><it>Plasmodium vivax </it>is estimated to affect 75 million people annually. It is reportedly absent, however, from west and central Africa due to the high prevalence of the Duffy negative phenotype in the indigenous populations. Despite this, non-African travellers consistently return to their own countries with <it>P. vivax </it>malaria after visiting this region. An attempt was made, therefore, to detect the presence of <it>P. vivax </it>parasites in blood samples collected from the indigenous populations of west and central Africa.</p> <p>Methods</p> <p>Parasite species typing (for all four human malaria parasites) was carried out by PCR on 2,588 blood samples collected from individuals from nine African malaria-endemic countries.</p> <p>Results</p> <p>Most infections (98.5%) were <it>Plasmodium falciparum</it>, <it>Plasmodium malariae </it>was identified in 8.5% of all infections, and <it>Plasmodium ovale </it>in 3.9%. The prevalence of both parasites varied greatly by country. Only one case of <it>P. vivax </it>was detected from Sao Tome, an island off the west coast of Africa, confirming the scarcity of this parasite in Africa.</p> <p>Conclusion</p> <p>The prevalence of <it>P. vivax </it>in local populations in sub-Saharan Africa is very low, despite the frequent identification of this parasite in non-African travellers.</p

    Exploring Cosmic Origins with CORE: Cosmological Parameters

    Get PDF
    We forecast the main cosmological parameter constraints achievable with theCORE space mission which is dedicated to mapping the polarisation of the CosmicMicrowave Background (CMB). CORE was recently submitted in response to ESA'sfifth call for medium-sized mission proposals (M5). Here we report the resultsfrom our pre-submission study of the impact of various instrumental options, inparticular the telescope size and sensitivity level, and review the great,transformative potential of the mission as proposed. Specifically, we assessthe impact on a broad range of fundamental parameters of our Universe as afunction of the expected CMB characteristics, with other papers in the seriesfocusing on controlling astrophysical and instrumental residual systematics. Inthis paper, we assume that only a few central CORE frequency channels areusable for our purpose, all others being devoted to the cleaning ofastrophysical contaminants. On the theoretical side, we assume LCDM as ourgeneral framework and quantify the improvement provided by CORE over thecurrent constraints from the Planck 2015 release. We also study the jointsensitivity of CORE and of future Baryon Acoustic Oscillation and Large ScaleStructure experiments like DESI and Euclid. Specific constraints on the physicsof inflation are presented in another paper of the series. In addition to thesix parameters of the base LCDM, which describe the matter content of aspatially flat universe with adiabatic and scalar primordial fluctuations frominflation, we derive the precision achievable on parameters like thosedescribing curvature, neutrino physics, extra light relics, primordial heliumabundance, dark matter annihilation, recombination physics, variation offundamental constants, dark energy, modified gravity, reionization and cosmicbirefringence. (ABRIDGED

    Health Assessment Questionnaire-Disability Index (HAQ-DI) use in modelling disease progression in diffuse cutaneous systemic sclerosis: an analysis from the EUSTAR database

    Get PDF
    BACKGROUND: Patients with diffuse cutaneous systemic sclerosis (dcSSc) have a poor prognosis. The importance of monitoring subjective measures of functioning and disability, such as the Health Assessment Questionnaire-Disability Index (HAQ-DI), is important as dcSSc is rated by patients as worse than diabetes or hemodialysis for quality of life impairment. This European Scleroderma Trials and Research (EUSTAR) database analysis was undertaken to examine the importance of impaired functionality in dcSSc prognosis. The primary objectives were to identify predictors of death and HAQ-DI score progression over 1 year. HAQ-DI score, major advanced organ involvement, and death rate were also used to develop a comprehensive model to predict lifetime dcSSc progression. METHODS: This was an observational, longitudinal study in patients with dcSSc registered in EUSTAR. Death and HAQ-DI scores were, respectively, analyzed by Cox regression and linear regression analyses in relation to baseline covariates. A microsimulation Markov model was developed to estimate/predict natural progression of dcSSc over a patient's lifetime. RESULTS: The analysis included dcSSc patients with (N = 690) and without (N = 4132) HAQ-DI score assessments from the EUSTAR database. Baseline HAQ-DI score, corticosteroid treatment, and major advanced organ involvement were predictive of death on multivariable analysis; a 1-point increase in baseline HAQ-DI score multiplied the risk of death by 2.7 (p &lt; &nbsp;0.001) and multiple advanced major organ involvement multiplied the risk of death by 2.8 (p &lt; &nbsp;0.05). Multivariable analysis showed that baseline modified Rodnan Skin Score (mRSS) and baseline HAQ-DI score were associated with HAQ-DI score progression at 1 year (p &lt; &nbsp;0.05), but there was no association between baseline organ involvement and HAQ-DI score progression at 1 year. HAQ-DI score, major advanced organ involvement, and death were successfully used to model long-term disease progression in dcSSc. CONCLUSIONS: HAQ-DI score and major advanced organ involvement were comparable predictors of mortality risk in dcSSc. Baseline mRSS and baseline HAQ-DI score were predictive of HAQ-DI score progression at 1 year, indicating a correlation between these endpoints in monitoring disease progression. It is hoped that this EUSTAR analysis may change physician perception about the importance of the HAQ-DI score in dcSSc

    Stratification in systemic sclerosis according to autoantibody status versus skin involvement: a study of the prospective EUSTAR cohort

    Get PDF
    Background: The current subclassification of systemic sclerosis into cutaneous subtypes does not fully capture the heterogeneity of the disease. We aimed to compare the performances of stratification into LeRoy's cutaneous subtypes versus stratification by autoantibody status in systemic sclerosis. Methods: For this cohort study, we assessed people with systemic sclerosis in the multicentre international European Scleroderma Trials and Research (EUSTAR) database. Individuals positive for systemic-sclerosis autoantibodies of two specificities were excluded, and remaining individuals were classified by cutaneous subtype, according to their systemic sclerosis-specific autoantibodies, or both. We assessed the performance of each model to predict overall survival, progression-free survival, disease progression, and different organ involvement. The three models were compared by use of the area under the curve (AUC) of the receiver operating characteristic and the net reclassification improvement (NRI). Missing data were imputed. Findings: We assessed the database on July 26, 2019. Of 16 939 patients assessed for eligibility, 10 711 patients were included: 1647 (15·4%) of 10 709 were male, 9062 (84·6%) were female, mean age was 54·4 (SD 13·8) years, and mean disease duration was 7·9 (SD 8·2) years. Information regarding cutaneous subtype was available for 10 176 participants and antibody data were available for 9643 participants. In the prognostic analysis, there was no difference in AUC for overall survival (0·82, 95% CI 0·81-0·84 for cutaneous only vs 0·84, 0·82-0·85 for antibody only vs 0·84, 0·83-0·86 for combined) or for progression-free survival (0·70, 0·69-0·71 vs 0·71, 0·70-0·72 vs 0·71, 0·70-0·72). However, at 4 years the NRI showed substantial improvement for the antibody-only model compared with the cutaneous-only model in prediction of overall survival (0·57, 0·46-0·71 for antibody only vs 0·29, 0·19-0·39 for cutaneous only) and disease progression (0·36, 0·29-0·46 vs 0·21, 0·14-0·28). The antibody-only model did better than the cutaneous-only model in predicting renal crisis (AUC 0·72, 0·70-0·74 for antibody only vs 0·66, 0·64-0·69 for cutaneous only) and lung fibrosis leading to restrictive lung function (AUC 0·76, 0·75-0·77 vs 0·71, 0·70-0·72). The combined model improved the prediction of digital ulcers and elevated systolic pulmonary artery pressure, but did poorly for cardiac involvement. Interpretation: The autoantibody-only model outperforms cutaneous-only subsetting for risk stratifying people with systemic sclerosis in the EUSTAR cohort. Physicians should be aware of these findings at the time of decision making for patient management. Funding: World Scleroderma Foundation

    Euclid Near Infrared Spectrometer and Photometer instrument concept and first test results obtained for different breadboards models at the end of phase C

    Get PDF
    The Euclid mission objective is to understand why the expansion of the Universe is accelerating through by mapping the geometry of the dark Universe by investigating the distance-redshift relationship and tracing the evolution of cosmic structures. The Euclid project is part of ESA's Cosmic Vision program with its launch planned for 2020 (ref [1]). The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments and is operating in the near-IR spectral region (900- 2000nm) as a photometer and spectrometer. The instrument is composed of: - a cold (135K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly (corrector and camera lens), a filter wheel mechanism, a grism wheel mechanism, a calibration unit and a thermal control system - a detection subsystem based on a mosaic of 16 HAWAII2RG cooled to 95K with their front-end readout electronic cooled to 140K, integrated on a mechanical focal plane structure made with molybdenum and aluminum. The detection subsystem is mounted on the optomechanical subsystem structure - a warm electronic subsystem (280K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data This presentation describes the architecture of the instrument at the end of the phase C (Detailed Design Review), the expected performance, the technological key challenges and preliminary test results obtained for different NISP subsystem breadboards and for the NISP Structural and Thermal model (STM)

    Clinical and biological effects of different energetic surgical devices currently used for mini-invasive anatomical lung resections for the treatment of NSCLC: a prospective interventional study

    No full text
    Background: This study aims to compare three commonly used energy devices for dissection during Video-Assisted Thoracoscopic Surgery (VATS) lobectomy: monopolar hook, advanced bipolar, and ultrasonic device, in terms of duration of the surgical procedure and clinical intra- and post-operative outcomes. Materials and methods: In this prospective single-center study, 75 patients undergoing VATS lobectomy for non-small cell lung cancer between January 2022 and May 2023 were enrolled and divided into 3 groups based on the device used during the surgical procedure (Group 1: Ultrasonic Device, Group 2: Advanced Bipolar, Group 3: Monopolar Hook). The duration of the surgical procedure, daily pleural fluid production, post-operative pain, length of hospital stay, and occurrence of post-operative complications were compared for each group. In a subgroup of 20 patients (10 from Group 1 and 10 from Group 3), concentrations of inflammatory cytokines in pleural fluid at 3&nbsp;h and 48&nbsp;h post-surgery were analyzed. Results: Pleural fluid production on the first and second post-operative days was significantly lower in patients treated with the Ultrasonic device compared to the other two groups (p &lt; 0.001). The duration of the surgical procedure was significantly shorter when using the Ultrasonic device (p &lt; 0.001). There were no significant differences in length of hospital stay (p = 0.975), pain on the first and second post-operative days (p = 0.147 and p = 0.755, respectively), and blood hemoglobin levels on the first post-operative day (p = 0.709) and at discharge (p = 0.795). No differences were observed in terms of post-operative complications, although the incidence of post-operative cardiac arrhythmias was borderline significant (p = 0.096), with no cases of arrhythmias recorded in Group 1. IL-10 levels in pleural fluid of patients in Group 3 peaked at 3&nbsp;h post-surgery, with a significant reduction at 48&nbsp;h (p = 0.459). Discussion: The use of the ultrasonic device during VATS lobectomy may reduce pleural fluid production and shorten the duration of the surgical procedure compared to using a monopolar hook or advanced bipolar device. The choice of energy device may influence the local inflammatory response, although further studies are needed to confirm these results

    PRISM (Polarized Radiation Imaging and Spectroscopy Mission): an extended white paper

    Get PDF
    Contains fulltext : 126057.pdf (preprint version ) (Open Access
    corecore