2,492 research outputs found

    Loss of correlation between HIV viral load and CD4+ T-cell counts in HIV/HTLV-1 co-infection in treatment naive Mozambican patients

    Get PDF
    Seven hundred and four HIV-1/2-positive, antiretroviral therapy (ART) naïve patients were screened for HTLV-1 infection. Antibodies to HTLV-1 were found in 32/704 (4.5%) of the patients. Each co-infected individual was matched with two HIV mono-infected patients according to World Health Organization clinical stage, age +/-5 years and gender. Key clinical and laboratory characteristics were compared between the two groups. Mono-infected and co-infected patients displayed similar clinical characteristics. However, co-infected patients had higher absolute CD4+ T-cell counts (P = 0.001), higher percentage CD4+ T-cell counts (P < 0.001) and higher CD4/CD8 ratios (P < 0.001). Although HIV plasma RNA viral loads were inversely correlated with CD4+ T-cell-counts in mono-infected patients (P < 0.0001), a correlation was not found in co-infected individuals (P = 0.11). Patients with untreated HIV and HTLV-1 co-infection show a dissociation between immunological and HIV virological markers. Current recommendations for initiating ART and chemoprophylaxis against opportunistic infections in resource-poor settings rely on more readily available CD4+ T-cell counts without viral load parameters. These guidelines are not appropriate for co-infected individuals in whom high CD4+ T-cell counts persist despite high HIV viral load states. Thus, for co-infected patients, even in resource-poor settings, HIV viral loads are likely to contribute information crucial for the appropriate timing of ART introduction

    Differential effects on membrane permeability and viability of human keratinocyte cells undergoing very low intensity megasonic fields

    Get PDF
    Among different therapeutic applications of Ultrasound (US), transient membrane sonoporation (SP) - a temporary, non-lethal porosity, mechanically induced in cell membranes through US exposure - represents a compelling opportunity towards an efficient and safe drug delivery. Nevertheless, progresses in this field have been limited by an insufficient understanding of the potential cytotoxic effects of US related to the failure of the cellular repair and to the possible activation of inflammatory pathway. In this framework we studied the in vitro effects of very low-intensity US on a human keratinocyte cell line, which represents an ideal model system of skin protective barrier cells which are the first to be involved during medical US treatments. Bioeffects linked to US application at 1 MHz varying the exposure parameters were investigated by fluorescence microscopy and fluorescence activated cell sorting. Our results indicate that keratinocytes undergoing low US doses can uptake drug model molecules with size and efficiency which depend on exposure parameters. According to sub-cavitation SP models, we have identified the range of doses triggering transient membrane SP, actually with negligible biological damage. By increasing US doses we observed a reduced cells viability and an inflammatory gene overexpression enlightening novel healthy relevant strategies

    Intracellular targeting and functional analysis of single-chain Fv fragments in mammalian cells

    Get PDF
    In the past decade, intracellular antibodies have proven to be a useful tool in obtaining the phenotypic knock-out of selected gene function in different animal and plant systems. This strategy is based on the ectopic expression of recombinant forms of antibodies targeted towards different intracellular compartments, exploiting specific targeting signals to confer the new intracellular location. The functional basis of this technology is closely linked to the ability of intracellular antibodies to interact with their target antigens in vivo. This interaction allows either a direct neutralising effect or the dislodgement of the target protein from its normal intracellular location and, by this mechanism, the inactivation of its function. By using this approach, the function of several antigens has been inhibited in the cytoplasm, the nucleus, and the secretory compartments. In this article, we shall describe all the steps required for expressing single-chain Fv fragments in different subcellular compartments of mammalian cells and their subsequent use in knock-out experiments, starting from a cloned single-chain Fv fragment. This will include the analysis of the solubility properties of the new scFv fragment in transfected mammalian cells, the intracellular distribution of the antigen-antibody complex, and the resulting phenotype

    Characterisation of the secondary-neutron production in particle therapy treatments with the MONDO tracking detector

    Get PDF
    Particle Therapy (PT) is a non-invasive technique that exploits charged light ions for the irradiation of tumours that cannot be effectively treated with surgery or conventional radiotherapy. While the largest dose fraction is released to the tumour volume by the primary beam, a non-negligible amount of additional dose is due to the beam fragmentation that occurs along the path towards the target volume. In particular, the produced neutrons are particularly dangerous as they can release their energy far away from the treated area, increasing the risk of developing a radiogenic secondary malignant neoplasm after undergoing a treatment. A precise measurement of the neutron flux, energy spectrum and angular distributions is eagerly needed in order to improve the treatment planning system software, so as to predict the normal tissue toxicity in the target region and the risk of late complications in the whole body. The MONDO (MOnitor for Neutron Dose in hadrOntherapy) project is dedicated to the characterisation of the secondary ultra-fast neutrons ([20-400] MeV energy range) produced in PT. The neutron tracking system exploits the reconstruction of the recoil protons produced in two consecutive (n, p) elastic scattering interactions to measure simultaneously the neutron incoming direction and energy. The tracker active media is a matrix of thin squared scintillating fibers arranged in orthogonally oriented layers that are read out by a sensor (SBAM) based on SPAD (Single-Photon Avalanche Diode) detectors developed in collaboration with the Fondazione Bruno Kessler (FBK)

    Measurement of charged particle yields from therapeutic beams in view of the design of an innovative hadrontherapy dose monitor

    Get PDF
    Particle Therapy (PT) is an emerging technique, which makes use of charged particles to efficiently cure different kinds of solid tumors. The high precision in the hadrons dose deposition requires an accurate monitoring to prevent the risk of under-dosage of the cancer region or of over-dosage of healthy tissues. Monitoring techniques are currently being developed and are based on the detection of particles produced by the beam interaction into the target, in particular: charged particles, result of target and/or projectile fragmentation, prompt photons coming from nucleus de-excitation and back-to-back γ s, produced in the positron annihilation from β + emitters created in the beam interaction with the target. It has been showed that the hadron beam dose release peak can be spatially correlated with the emission pattern of these secondary particles. Here we report about secondary particles production (charged fragments and prompt γ s) performed at different beam and energies that have a particular relevance for PT applications: 12C beam of 80 MeV/u at LNS, 12C beam 220 MeV/u at GSI, and 12C, 4He, 16O beams with energy in the 50–300 MeV/u range at HIT. Finally, a project for a multimodal dose-monitor device exploiting the prompt photons and charged particles emission will be presented

    In-room test results at CNAO of an innovative PT treatments online monitor (Dose Profiler)

    Get PDF
    The use of C, He and O ions as projectiles in Particle Therapy (PT) treatments is getting more and more widespread as a consequence of their enhanced relative biological effectiveness and oxygen enhancement ratio, when compared to the protons one. The advantages related to the incoming radiation improved efficacy are requiring an accurate online monitor of the dose release spatial distribution. Such monitor is necessary to prevent unwanted damage to the tissues surrounding the tumour that can arise, for example, due to morphological changes occurred in the patient during the treatment with respect to the initial CT scan. PT treatments with ions can be monitored by detecting the secondary radiation produced by the primary beam interactions with the patient body along the path towards the target volume. Charged fragments produced in the nuclear process of projectile fragmentation can be emitted at large angles with respect to the incoming beam direction and can be detected with high efficiency in a nearly background-free environment. The Dose Profiler (DP) detector, developed within the INSIDE project, is a scintillating fibre tracker that allows an online reconstruction and backtracking of such secondary charged fragments. The construction and preliminary in-room tests performed on the DP, carried out using the 12C ions beam of the CNAO treatment centre using an anthropomorphic phantom as a target, will be reviewed in this contribution. The impact of the secondary fragments interactions with the patient body will be discussed in view of a clinical application. Furthermore, the results implications for a pre-clinical trial on CNAO patients, foreseen in 2019, will be discussed
    corecore