649 research outputs found
In situ characterization of vertically oriented carbon nanofibers for three-dimensional nano-electro-mechanical device applications
We have performed mechanical and electrical characterization of individual as-grown, vertically oriented carbon nanofibers (CNFs) using in situ techniques, where such high-aspect-ratio, nanoscale structures are of interest for three-dimensional (3D) electronics, in particular 3D nano-electro-mechanical-systems (NEMS). Nanoindentation and uniaxial compression tests conducted in an in situ nanomechanical instrument, SEMentor, suggest that the CNFs undergo severe bending prior to fracture, which always occurs close to the bottom rather than at the substrate–tube interface, suggesting that the CNFs are well adhered to the substrate. This is also consistent with bending tests on individual tubes which indicated that bending angles as large as ~70° could be accommodated elastically. In situ electrical transport measurements revealed that the CNFs grown on refractory metallic nitride buffer layers were conducting via the sidewalls, whereas those synthesized directly on Si were electrically unsuitable for low-voltage dc NEMS applications. Electrostatic actuation was also demonstrated with a nanoprobe in close proximity to a single CNF and suggests that such structures are attractive for nonvolatile memory applications. Since the magnitude of the actuation voltage is intimately dictated by the physical characteristics of the CNFs, such as diameter and length, we also addressed the ability to tune these parameters, to some extent, by adjusting the plasma-enhanced chemical vapor deposition growth parameters with this bottom-up synthesis approach
Monolithically Integrated, Mechanically Resilient Carbon-Based Probes for Scanning Probe Microscopy
Scanning probe microscopy (SPM) is an important tool for performing measurements at the nanoscale in imaging bacteria or proteins in biology, as well as in the electronics industry. An essential element of SPM is a sharp, stable tip that possesses a small radius of curvature to enhance spatial resolution. Existing techniques for forming such tips are not ideal. High-aspect-ratio, monolithically integrated, as-grown carbon nanofibers (CNFs) have been formed that show promise for SPM applications by overcoming the limitations present in wet chemical and separate substrate etching processes
Characterization and Improvement of the Thermal Stability of TES Bolometers
We study the mechanism of instability in transition edge sensor (TES) bolometers used for ground based observations of the Cosmic Microwave Background (CMB) at 270GHz. The instability limits the range of useful operating resistances of the TES down to ≈50% of R_n, and due to variations in detector properties and optical loading within a column of multiplexed detectors, limits the effective on sky yield. Using measurements of the electrical impedance of the detectors, we show the instability is due to the increased bolometer leg G for higher-frequency detection inducing decoupling of the palladium-gold heat capacity from the thermistor. We demonstrate experimentally that the limiting thermal resistance is due to the small cross sectional area of the silicon nitride bolometer island, and so is easily fixed by layering palladium-gold over an oxide protected TES. The resulting detectors can be biased down to a resistance ≈10% of R_n
Evaluation of the usefulness of three-dimensional optical coherence tomography in a guinea pig model of endolymphatic hydrops induced by surgical obliteration of the endolymphatic duct
Optical coherence tomography (OCT) has advanced significantly over the past two decades and is currently used extensively to monitor the internal structures of organs, particularly in ophthalmology and dermatology. We used ethylenediamine tetra-acetic acid (EDTA) to decalcify the bony walls of the cochlea and investigated the inner structures by deep penetration of light into the cochlear tissue using OCT on a guinea pig model of endolymphatic hydrops (EH), induced by surgical obliteration of the endolymphatic duct. The structural and functional changes associated with EH were identified using OCT and auditory brainstem response tests, respectively. We also evaluated structural alterations in the cochlea using three-dimensional reconstruction of the OCT images, which clearly showed physical changes in the cochlear structures. Furthermore, we found significant anatomical variations in the EH model and conducted graphical analysis by strial atrophy for comparison. The physical changes included damage to and flattening of the organ of Corti-evidence of Reissner's membrane distention-and thinning of the lateral wall. These results indicate that observation of EDTA-decalcified cochlea using OCT is significant in examination of gradual changes in the cochlear structures that are otherwise not depicted by hematoxylin and eosin staining © The Authorsopen0
Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures
Plasma-enhanced chemical vapor deposition (PECVD) and high-throughput manufacturing techniques for integrating single, aligned carbon nanotubes (CNTs) into novel 3D nanoscale architectures have been developed. First, the PECVD growth technique ensures excellent alignment of the tubes, since the tubes align in the direction of the electric field in the plasma as they are growing. Second, the tubes generated with this technique are all metallic, so their chirality is predetermined, which is important for electronic applications. Third, a wafer-scale manufacturing process was developed that is high-throughput and low-cost, and yet enables the integration of just single, aligned tubes with nanoscale 3D architectures with unprecedented placement accuracy and does not rely on e-beam lithography. Such techniques should lend themselves to the integration of PECVD grown tubes for applications ranging from interconnects, nanoelectromechanical systems (NEMS), sensors, bioprobes, or other 3D electronic devices. Chemically amplified polyhydroxystyrene-resin-based deep UV resists were used in conjunction with excimer laser-based (lambda = 248 nm) step-and-repeat lithography to form Ni catalyst dots = 300 nm in diameter that nucleated single, vertically aligned tubes with high yield using dc PECVD growth. This is the first time such chemically amplified resists have been used, resulting in the nucleation of single, vertically aligned tubes. In addition, novel 3D nanoscale architectures have been created using topdown techniques that integrate single, vertically aligned tubes. These were enabled by implementing techniques that use deep-UV chemically amplified resists for small-feature-size resolution; optical lithography units that allow unprecedented control over layer-to-layer registration; and ICP (inductively coupled plasma) etching techniques that result in near-vertical, high-aspect-ratio, 3D nanoscale architectures, in conjunction with the use of materials that are structurally and chemically compatible with the high-temperature synthesis of the PECVD-grown tubes. The techniques offer a wafer-scale process solution for integrating single PECVD-grown nanotubes into novel architectures that should accelerate their integration in 3D electronics in general. NASA can directly benefit from this technology for its extreme-environment planetary missions. Current Si transistors are inherently more susceptible to high radiation, and do not tolerate extremes in temperature. These novel 3D nanoscale architectures can form the basis for NEMS switches that are inherently less susceptible to radiation or to thermal extremes
Approximation Algorithm for Line Segment Coverage for Wireless Sensor Network
The coverage problem in wireless sensor networks deals with the problem of
covering a region or parts of it with sensors. In this paper, we address the
problem of covering a set of line segments in sensor networks. A line segment `
is said to be covered if it intersects the sensing regions of at least one
sensor distributed in that region. We show that the problem of finding the
minimum number of sensors needed to cover each member in a given set of line
segments in a rectangular area is NP-hard. Next, we propose a constant factor
approximation algorithm for the problem of covering a set of axis-parallel line
segments. We also show that a PTAS exists for this problem.Comment: 16 pages, 5 figures
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
We describe the SPIDER flight cryostat, which is designed to cool six
millimeter-wavelength telescopes during an Antarctic long-duration balloon
flight. The cryostat, one of the largest to have flown on a stratospheric
payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6
K. Stainless steel capillaries facilitate a high flow impedance connection
between the main liquid helium tank and a smaller superfluid tank, allowing the
latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank.
Each telescope houses a closed cycle helium-3 adsorption refrigerator that
further cools the focal planes down to 300 mK. Liquid helium vapor from the
main tank is routed through heat exchangers that cool radiation shields,
providing negative thermal feedback. The system performed successfully during a
17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold
time of 16.8 days, with 15.9 days occurring during flight.Comment: 15 pgs, 17 fig
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
We introduce the light-weight carbon fiber and aluminum gondola designed for
the SPIDER balloon-borne telescope. SPIDER is designed to measure the
polarization of the Cosmic Microwave Background radiation with unprecedented
sensitivity and control of systematics in search of the imprint of inflation: a
period of exponential expansion in the early Universe. The requirements of this
balloon-borne instrument put tight constrains on the mass budget of the
payload. The SPIDER gondola is designed to house the experiment and guarantee
its operational and structural integrity during its balloon-borne flight, while
using less than 10% of the total mass of the payload. We present a construction
method for the gondola based on carbon fiber reinforced polymer tubes with
aluminum inserts and aluminum multi-tube joints. We describe the validation of
the model through Finite Element Analysis and mechanical tests.Comment: 16 pages, 11 figures. Presented at SPIE Ground-based and Airborne
Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume
914
BICEP2 / Keck Array VIII: Measurement of gravitational lensing from large-scale B-mode polarization
We present measurements of polarization lensing using the 150 GHz maps which
include all data taken by the BICEP2 & Keck Array CMB polarization experiments
up to and including the 2014 observing season (BK14). Despite their modest
angular resolution (), the excellent sensitivity (K-arcmin) of these maps makes it possible to directly reconstruct the
lensing potential using only information at larger angular scales (). From the auto-spectrum of the reconstructed potential we measure an
amplitude of the spectrum to be (Planck
CDM prediction corresponds to ), and reject
the no-lensing hypothesis at 5.8, which is the highest significance
achieved to date using an EB lensing estimator. Taking the cross-spectrum of
the reconstructed potential with the Planck 2015 lensing map yields
. These direct measurements of
are consistent with the CDM cosmology, and with
that derived from the previously reported BK14 B-mode auto-spectrum (). We perform a series of null tests and consistency
checks to show that these results are robust against systematics and are
insensitive to analysis choices. These results unambiguously demonstrate that
the B-modes previously reported by BICEP / Keck at intermediate angular scales
() are dominated by gravitational lensing. The
good agreement between the lensing amplitudes obtained from the lensing
reconstruction and B-mode spectrum starts to place constraints on any
alternative cosmological sources of B-modes at these angular scales.Comment: 12 pages, 8 figure
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
We have developed antenna-coupled transition-edge sensor (TES) bolometers for
a wide range of cosmic microwave background (CMB) polarimetry experiments,
including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors
have reached maturity and this paper reports on their design principles,
overall performance, and key challenges associated with design and production.
Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at
95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric
co-aligned beams with controlled side-lobe levels. Cross-polarized response on
boresight is typically ~0.5%, consistent with cross-talk in our multiplexed
readout system. End-to-end optical efficiencies in our cameras are routinely
35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the
scalability of this design, we have deployed 2560 detectors as 1280 matched
pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as
measured directly from CMB maps in the 2013 season. Similar arrays have
recently flown in the SPIDER instrument, and development of this technology is
ongoing.Comment: 16 pgs, 20 fig
- …