209 research outputs found
Signatures of Le´vy flights with annealed disorder
We present theoretical and experimental results of Le´vy flights of light originating from a random walk of
photons in a hot atomic vapor. In contrast to systems with quenched disorder, this system does not present any
correlations between the position and the step length of the random walk. In an analytical model based on micro-
scopic first principles including Doppler broadening we find anomalous Le´vy-type superdiffusion corresponding
to a single-step size distribution P (x) ∝ x−(1+α), with α ≈ 1. We show that this step size distribution leads to a
violation of Ohm’s law [Tdiff ∝ L−α/2 = L−1], as expected for a Le´vy walk of independent steps. Furthermore,
the spatial profile of the transmitted light develops power-law tails [Tdiff(r) ∝ r−3−α]. In an experiment using a
slab geometry with hot Rb vapor, we measured the total diffuse transmission Tdiff and the spatial profile of the
transmitted light Tdiff(r). We obtained the microscopic Le´vy parameter α under macroscopic multiple scattering
conditions paving the way to investigation of Le´vy flights in different atomic physics and astrophysics systems.We thank Dominique Delande for fruitful discussions and we acknowledge funding for N.M. and Q.B. by the french Direction Generale de l'Armement. R.P acknowledges the support of LABEX WIFI (Laboratory of Excellence ANR-10-LABX-24) within the French Program "Investments for the Future" under reference ANR-10-IDEX-0001-02 PSL*. E.J.N. and R.K. acknowledge the FCT/CNRS exchange program (441.00 CNRS)
Ultrafast decoupling of polarization and strain in ferroelectric BaTiO<sub>3</sub>
A fundamental understanding of the interplay between lattice structure, polarization and electrons is pivotal to the optical control of ferroelectrics. The interaction between light and matter enables the remote and wireless control of the ferroelectric polarization on the picosecond timescale, while inducing strain, i.e., lattice deformation. At equilibrium, the ferroelectric polarization is proportional to the strain, and is typically assumed to be so also out of equilibrium. Decoupling the polarization from the strain would remove the constraint of sample design and provide an effective knob to manipulate the polarization by light. Here, upon above-bandgap laser excitation of the prototypical ferroelectric BaTiO3, we induce and measure an ultrafast decoupling between polarization and strain that begins within 350 fs, by softening Ti-O bonds via charge transfer, and lasts for several tens of picoseconds. We show that the ferroelectric polarization out of equilibrium is mainly determined by photoexcited electrons, instead of the strain
Optical control of 4f orbital state in rare-earth metals
Information technology demands continuous increase of data-storage density.
In high-density magnetic recording media, the large magneto-crystalline
anisotropy (MCA) stabilizes the stored information against decay through
thermal fluctuations. In the latest generation storage media, MCA is so large
that magnetic order needs to be transiently destroyed by heat to enable bit
writing. Here we show an alternative approach to control high-anisotropy
magnets: With ultrashort laser pulses the anisotropy itself can be manipulated
via electronic state excitations. In rare-earth materials like terbium metal,
magnetic moment and high MCA both originate from the 4f electronic state.
Following infrared laser excitation 5d-4f electron-electron scattering
processes lead to selective orbital excitations that change the 4f orbital
occupation and significantly alter the MCA. Besides these excitations within
the 4f multiplet, 5d-4f electron transfer causes a transient change of the 4f
occupation number, which, too, strongly alters the MCA. Such MCA change cannot
be achieved by heating: The material would rather be damaged than the 4f
configuration modified. Our results show a way to overcome this limitation for
a new type of efficient magnetic storage medium. Besides potential
technological relevance, the observation of MCA-changing excitations also has
implications for a general understanding of magnetic dynamics processes on
ultrashort time scales, where the 4f electronic state affects the angular
momentum transfer between spin system and lattice.Comment: Manuscript (14 pages, 3 figures) and Supplementary Information (22
pages, 9 figures
Photo-generated charge-transfer excitons in NiO revealed by ultrafast time-resolved resonant inelastic x-ray scattering
Strong electronic correlation can lead to insulating behavior and to the opening of large optical gaps, even in materials with partly filled valence shells. Although the non-equilibrium optical response encodes both local (quasi atomic) and collective (long range) responses, optical spectroscopy is usually more sensitive to the latter. Resonant x-ray techniques are better suited to investigate the quasi-atomic properties of correlated solids. Using time-resolved resonant inelastic x-ray scattering (RIXS), here we study the ultrafast non-equilibrium processes in NiO following photo-excitation by ultraviolet photons with energy exceeding the optical gap. We observe the creation of charge-transfer excitons that decay with a time constant of about 2\,ps, while itinerant photo-doping persists for tens of picoseconds. Following our discovery, which establishes time-resolved high-resolution RIXS as a powerful tool for the study of transient phenomena in condensed matter, the possible presence of charge-transfer excitons will need to be considered when interpreting optical pump-probe experiments on correlated quantum materials
How Similar Are the Mice to Men? Between-Species Comparison of Left Ventricular Mechanics Using Strain Imaging
BACKGROUND: While mammalian heart size maintains constant proportion to whole body size, scaling of left ventricular (LV) function parameters shows a more complex scaling pattern. We used 2-D speckle tracking strain imaging to determine whether LV myocardial strains and strain rates scale to heart size. METHODS: We studied 18 mice, 15 rats, 6 rabbits, 12 dogs and 20 human volunteers by 2-D echocardiography. Relationship between longitudinal or circumferential strains/strain rates (S(Long)/SR(Long), S(Circ)/SR(Circ)), and LV end-diastolic volume (EDV) or mass were assessed by the allometric (power-law) equation Y = kM(β). RESULTS: Mean LV mass in individual species varied from 0.038 to 134 g, LV EDV varied from 0.015 to 102 ml, while RR interval varied from 81 to 1090 ms. While S(Long) increased with increasing LV EDV or mass (β values 0.047±0.006 and 0.051±0.005, p<0.0001 vs. 0 for both) S(Circ) was unchanged (p = NS for both LV EDV or mass). Systolic and diastolic SR(Long) and SR(Circ) showed inverse correlations to LV EDV or mass (p<0.0001 vs. 0 for all comparisons). The ratio between S(Long) and S(Circ) increased with increasing values of LV EDV or mass (β values 0.039±0.010 and 0.040±0.011, p>0.0003 for both). CONCLUSIONS: While S(Circ) is unchanged, S(Long) increases with increasing heart size, indicating that large mammals rely more on long axis contribution to systolic function. SR(Long) and SR(Circ), both diastolic and systolic, show an expected decrease with increasing heart size
Analysis of long-lived effects in high-repetition-rate stroboscopic transient X-ray absorption experiments on thin films
Time-resolved X-ray absorption spectroscopy (tr-XAS) has been shown to be a versatile measurement technique for investigating non-equilibrium dynamics. Novel X-ray free electron laser (XFEL) facilities like the European XFEL offer increased repetition rates for stroboscopic XAS experiments through a burst operation mode, which enables measurements with up to 4.5 MHz. These higher repetition rates lead to higher data acquisition rates but can also introduce long-lived excitations that persist and thus build up during each burst. Here, we report on such long-lived effects in Ni and NiO thin film samples that were measured at the European XFEL. We disentangle the long-lived excitations from the initial pump-induced change and perform a detailed modelling-based analysis of how they modify transient X-ray spectra. As a result, we link the long-lived effects in Ni to a local temperature increase, as well as the effects in NiO to excited charge carrier trapping through polaron formation. In addition, we present possible correction methods, as well as discuss ways in which the effects of these long-lived excitations could be minimized for future time-resolved X-ray absorption spectroscopy measurements
The interplay of local electron correlations and ultrafast spin dynamics in fcc Ni
The complex electronic structure of metallic ferromagnets is determined by a balance between exchange interaction, electron hopping leading to band formation, and local Coulomb repulsion. The interplay between the respective terms of the Hamiltonian is of fundamental interest, since it produces most, if not all, of the exotic phenomena observed in the solid state. By combining high energy and temporal resolution in femtosecond time-resolved X-ray absorption spectroscopy with ab initio time-dependent density functional theory we analyze the electronic structure in fcc Ni on the time scale of these interactions in a pump-probe experiment. We distinguish transient broadening and energy shifts in the absorption spectra, which we demonstrate to be caused by electron repopulation and correlation-induced modifications of the electronic structure, respectively. Importantly, the theoretical description of this experimental result hence requires to take the local Coulomb interaction into account, revealing a temporal interplay between band formation, exchange interaction, and Coulomb repulsion
Megahertz-rate ultrafast X-ray scattering and holographic imaging at the European XFEL
The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, results from the first megahertz-repetition-rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL are presented. The experimental capabilities that the SCS instrument offers, resulting from the operation at megahertz repetition rates and the availability of the novel DSSC 2D imaging detector, are illustrated. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range
Myosin heavy chain and physiological adaptation of the rat diaphragm in elastase-induced emphysema
BACKGROUND: Several physiological adaptations occur in the respiratory muscles in rodent models of elastase-induced emphysema. Although the contractile properties of the diaphragm are altered in a way that suggests expression of slower isoforms of myosin heavy chain (MHC), it has been difficult to demonstrate a shift in MHCs in an animal model that corresponds to the shift toward slower MHCs seen in human emphysema. METHODS: We sought to identify MHC and corresponding physiological changes in the diaphragms of rats with elastase-induced emphysema. Nine rats with emphysema and 11 control rats were studied 10 months after instillation with elastase. MHC isoform composition was determined by both reverse transcriptase polymerase chain reaction (RT-PCR) and immunocytochemistry by using specific probes able to identify all known adult isoforms. Physiological adaptation was studied on diaphragm strips stimulated in vitro. RESULTS: In addition to confirming that emphysematous diaphragm has a decreased fatigability, we identified a significantly longer time-to-peak-tension (63.9 ± 2.7 ms versus 53.9 ± 2.4 ms). At both the RNA (RT-PCR) and protein (immunocytochemistry) levels, we found a significant decrease in the fastest, MHC isoform (IIb) in emphysema. CONCLUSION: This is the first demonstration of MHC shifts and corresponding physiological changes in the diaphragm in an animal model of emphysema. It is established that rodent emphysema, like human emphysema, does result in a physiologically significant shift toward slower diaphragmatic MHC isoforms. In the rat, this occurs at the faster end of the MHC spectrum than in humans
Photon shot-noise limited transient absorption soft X-ray spectroscopy at the European XFEL
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we present a dedicated setup for soft X-rays available at the Spectroscopy & Coherent Scattering (SCS) instrument at the European X-ray Free Electron Laser (EuXFEL). It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot-by-shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, the DSSC imaging detector, which is capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst, is employed and allows approaching the photon shot-noise limit. We review the setup and its capabilities, as well as the online and offline analysis tools provided to users
- …
