1,878 research outputs found

    National Dances of The Nutcracker : A Study of Racial, Cultural, and National Depictions in a Classical Ballet

    Get PDF
    Character development is a large component of ballet performance that is integrated into each rehearsal process leading up to the show. In this year’s production of The Nutcracker, I danced the role of Chinese Soloist. As I began my character development, I asked myself, “How does a Chinese girl dance?” When the question is asked about other roles, it is easy to respond; however, when the character is tied to a specific nationality it becomes much more difficult. Generalization and cultural misrepresentation become possible risks. Alastair Macaulay explains in his article Stereotypes in Toeshoes¸ “The ranks of ballet companies contain dancers of varied backgrounds; race-blind casting and interracial partnerships have been widespread for decades. Yet cliched and sometimes offensive views of race remain alive and well across the art form. Several of the old ballets and a few of the new ones give us national and racial stereotypes that would be un-showable in a play or movie. And yet they draw audiences” (New York Times 2012). I have researched the cultural dances included in classical ballets, focusing on The Nutcracker, and investigated why it continues to draw audiences. My research and investigation has helped me to answer the questions: Where did the inclusion of national dances in The Nutcracker originate? Do the national dances authentically represent the cultures of each nationality? Are cultural misrepresentations an accepted aspect of classical ballets

    Fatiguing Trunk Flexor Exercise Decreases Pain Sensitivity in Postpartum Women

    Get PDF
    Background: Low back pain (LBP) is common in the general population and among postpartum women. Abdominal muscle exercise is often used to treat LBP, but it is unknown if fatiguing abdominal muscle exercise can produce exercise-induced hypoalgesia (EIH). Objectives: To assess pressure pain thresholds (PPTs) at rest and following fatiguing trunk flexor exercise (EIH) in (1) nulligravid and postpartum women to evaluate the impact of pregnancy and childbirth and (2) nulligravid women and men to examine sex differences. Methods: Seventy healthy adults (31 postpartum women, 23 nulligravid women, 16 men) participated. Postpartum and nulligravid women were tested twice (16–18 weeks apart) to identify changes in EIH with postpartum recovery. PPTs were measured at the nailbed and superior rectus abdominis before and after exercise to investigate systemic and local EIH, respectively. Rectus abdominis muscle thickness was assessed with ultrasound. Results: Postpartum women reported lower PPTs than nulligravid women at the abdomen (p \u3c 0.05) whereas postpartum women had lower PPTs at the nailbed during the first session only. Men reported higher nailbed PPTs (p = 0.047) and similar PPTs at the abdomen than women (p = 0.294). All groups demonstrated EIH at the abdomen (p \u3c 0.05). Systemic EIH was absent in postpartum and nulligravid women (p \u3e 0.05), while men demonstrated hyperalgesia. Local EIH was positively associated with muscle thickness for men and women, which was not significant at the second timepoint. Limitations: Acute exercise response may not reflect changes that occur with exercise training. Conclusion: Fatiguing trunk flexor exercise produced local EIH for all groups including postpartum and nulligravid women. Clinically, trunk exercises may be useful for acute pain relief for clinical populations that are characterized by pain and/or weakness in the abdominal region muscles in populations with abdominal pain syndromes

    Long-term and recent changes in sea level in the Falkland Islands

    Get PDF
    Mean sea level measurements made at Port Louis in the Falkland Islands in 1981-2, 1984 and 2009, together with values from the nearby permanent tide gauge at Port Stanley, have been compared to measurements made at Port Louis in 1842 by James Clark Ross. The long-term rate of change of sea level is estimated to have been +0.75 ± 0.35 mm/year between 1842 and the early 1980s, after correction for air pressure effects and for vertical land movement due to Glacial Isostatic Adjustment (GIA). The 2009 Port Louis data set is of particular importance due to the availability of simultaneous information from Port Stanley. The data set has been employed in two ways, by providing a short recent estimate of mean sea level itself, and by enabling the effective combination of measurements at the two sites. The rate of sea level rise observed since 1992, when the modern Stanley gauge was installed, has been larger at 2.51 ± 0.58 mm/year, after correction for air pressure and GIA. This rate compares to a value of 2.79 ± 0.42 mm/year obtained from satellite altimetry in the region over the same period. Such a relatively recent acceleration in the rate of sea level rise is consistent with findings from other locations in the southern hemisphere and globall

    Packaging Technologies for High Temperature Electronics and Sensors

    Get PDF
    This paper reviews ceramic substrates and thick-film metallization based packaging technologies in development for 500degC silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chiplevel packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550degC. A 96% alumina based edge connector for a PCB level subsystem interconnection has also been demonstrated recently. The 96% alumina packaging system composed of chip-level packages and PCBs has been tested with high temperature SiC devices at 500degC for over 10,000 hours. In addition to tests in a laboratory environment, a SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE-7 suite to the International Space Station via a Shuttle mission. This packaged SiC transistor was successfully tested in orbit for eighteen months. A spark-plug type sensor package designed for high temperature SiC capacitive pressure sensors was developed. This sensor package combines the high temperature interconnection system with a commercial high temperature high pressure stainless steel seal gland (electrical feed-through). Test results of a packaged high temperature capacitive pressure sensor at 500degC are also discussed. In addition to the pressure sensor package, efforts for packaging high temperature SiC diode-based gas chemical sensors are in process

    Burden of disease from inadequate water, sanitation and hygiene in low- and middle-income settings: a retrospective analysis of data from 145 countries

    Get PDF
    objective To estimate the burden of diarrhoeal diseases from exposure to inadequate water, sanitation and hand hygiene in low- and middle-income settings and provide an overview of the impact on other diseases. methods For estimating the impact of water, sanitation and hygiene on diarrhoea, we selected exposure levels with both sufficient global exposure data and a matching exposure-risk relationship. Global exposure data were estimated for the year 2012, and risk estimates were taken from the most recent systematic analyses. We estimated attributable deaths and disability-adjusted life years (DALYs) by country, age and sex for inadequate water, sanitation and hand hygiene separately, and as a cluster of risk factors. Uncertainty estimates were computed on the basis of uncertainty surrounding exposure estimates and relative risks. results In 2012, 502 000 diarrhoea deaths were estimated to be caused by inadequate drinking water and 280 000 deaths by inadequate sanitation. The most likely estimate of disease burden from inadequate hand hygiene amounts to 297 000 deaths. In total, 842 000 diarrhoea deaths are estimated to be caused by this cluster of risk factors, which amounts to 1.5% of the total disease burden and 58% of diarrhoeal diseases. In children under 5 years old, 361 000 deaths could be prevented, representing 5.5% of deaths in that age group. conclusions This estimate confirms the importance of improving water and sanitation in low- and middle-income settings for the prevention of diarrhoeal disease burden. It also underscores the need for better data on exposure and risk reductions that can be achieved with provision of reliable piped water, community sewage with treatment and hand hygiene

    Packaging Technologies for High Temperature Electronics and Sensors

    Get PDF
    This paper reviews ceramic substrates and thick-film metallization based packaging technologies in development for 500 C silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chip-level packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550 C. A 96% alumina based edge connector for a PCB level subsystem interconnection has also been demonstrated recently. The 96% alumina packaging system composed of chip-level packages and PCBs has been tested with high temperature SiC devices at 500 C for over 10,000 hours. In addition to tests in a laboratory environment, a SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE-7 suite to the International Space Station via a Shuttle mission. This packaged SiC transistor was successfully tested in orbit for eighteen months. A spark-plug type sensor package designed for high temperature SiC capacitive pressure sensors was developed. This sensor package combines the high temperature interconnection system with a commercial high temperature high pressure stainless steel seal gland (electrical feed-through). Test results of a packaged high temperature capacitive pressure sensor at 500 C are also discussed. In addition to the pressure sensor package, efforts for packaging high temperature SiC diode-based gas chemical sensors are in process

    High Temperature Capacitive Pressure Sensor Employing a SiC Based Ring Oscillator

    Get PDF
    In an effort to develop harsh environment electronic and sensor technologies for aircraft engine safety and monitoring, we have used capacitive-based pressure sensors to shift the frequency of a SiC-electronics-based oscillator to produce a pressure-indicating signal that can be readily transmitted, e.g. wirelessly, to a receiver located in a more benign environment. Our efforts target 500 C, a temperature well above normal operating conditions of commercial circuits but within areas of interest in aerospace engines, deep mining applications and for future missions to the Venus atmosphere. This paper reports for the first time a ring oscillator circuit integrated with a capacitive pressure sensor, both operating at 500 C. This demonstration represents a significant step towards a wireless pressure sensor that can operate at 500 C and confirms the viability of 500 C electronic sensor systems

    High Temperature, Wireless Seismometer Sensor for Venus

    Get PDF
    Space agency mission plans state the need to measure the seismic activity on Venus. Because of the high temperature on Venus (462? C average surface temperature) and the difficulty in placing and wiring multiple sensors using robots, a high temperature, wireless sensor using a wide bandgap semiconductor is an attractive option. This paper presents the description and proof of concept measurements of a high temperature, wireless seismometer sensor for Venus. A variation in inductance of a coil caused by the movement of an aluminum probe held in the coil and attached to a balanced leaf-spring seismometer causes a variation of 700 Hz in the transmitted signal from the oscillator/sensor system at 426? C. This result indicates that the concept may be used on Venus

    Take to the Stage: Intersections of Integrative Healthcare, Human Development, and Psychological Recovery

    Get PDF
    2020 research posterhttps://digitalcommons.library.uab.edu/uabh-rd-all/1156/thumbnail.jp
    corecore