255 research outputs found

    Assessment of aortic stiffness by cardiovascular magnetic resonance following the treatment of severe aortic stenosis by TAVI and surgical AVR

    Get PDF
    Aortic stiffness is increasingly used as an independent predictor of adverse cardiovascular outcomes. We sought to compare the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon aortic vascular function using cardiovascular magnetic resonance (CMR) measurements of aortic distensibility and pulse wave velocity (PWV).A 1.5 T CMR scan was performed pre-operatively and at 6 m post-intervention in 72 patients (32 TAVI, 40 SAVR; age 76 ± 8 years) with high-risk symptomatic severe aortic stenosis. Distensibility of the ascending and descending thoracic aorta and aortic pulse wave velocity were determined at both time points. TAVI and SAVR patients were comparable for gender, blood pressure and left ventricular ejection fraction. The TAVI group were older (81 ± 6.3 vs. 72.8 ± 7.0 years, p < 0.05) with a higher EuroSCORE II (5.7 ± 5.6 vs. 1.5 ± 1.0 %, p < 0.05). At 6 m, SAVR was associated with a significant decrease in distensibility of the ascending aorta (1.95 ± 1.15 vs. 1.57 ± 0.68 × 10(-3)mmHg(-1), p = 0.044) and of the descending thoracic aorta (3.05 ± 1.12 vs. 2.66 ± 1.00 × 10(-3)mmHg(-1), p = 0.018), with a significant increase in PWV (6.38 ± 4.47 vs. 11.01 ± 5.75 ms(-1), p = 0.001). Following TAVI, there was no change in distensibility of the ascending aorta (1.96 ± 1.51 vs. 1.72 ± 0.78 × 10(-3)mmHg(-1), p = 0.380), descending thoracic aorta (2.69 ± 1.79 vs. 2.21 ± 0.79 × 10(-3)mmHg(-1), p = 0.181) nor in PWV (8.69 ± 6.76 vs. 10.23 ± 7.88 ms(-1), p = 0.301) at 6 m.Treatment of symptomatic severe aortic stenosis by SAVR but not TAVI was associated with an increase in aortic stiffness at 6 months. Future work should focus on the prognostic implication of these findings to determine whether improved patient selection and outcomes can be achieved

    Reservoir pressure analysis of aortic blood pressure: an in-vivo study at five locations in humans

    Get PDF
    INTRODUCTION:: The development and propagation of the aortic blood pressure wave remains poorly understood, despite its clear relevance to major organ blood flow and potential association with cardiovascular outcomes. The reservoir pressure model provides a unified description of the dual conduit and reservoir functions of the aorta. Reservoir waveform analysis resolves the aortic pressure waveform into an excess (wave related) and reservoir (compliance related) pressure. The applicability of this model to the pressure waveform as it propagates along the aorta has not been investigated in humans. METHODS:: We analysed invasively acquired high-fidelity aortic pressure waveforms from 40 patients undergoing clinically indicated coronary catheterization. Aortic waveforms were measured using a solid-state pressure catheter at five anatomical sites: the ascending aorta, the transverse aortic arch, the diaphragm, the level of the renal arteries, and at the aortic bifurcation. Ensemble average pressure waveforms were obtained for these sites for each patient and analysed to obtain the reservoir pressure [Pr(t)] and the excess pressure [Px(t)] at each aortic position. RESULTS:: Systolic blood pressure increased at a rate of 2.1?mmHg per site along the aorta, whereas diastolic blood pressure was effectively constant. Maximum Pr decreased only slightly along the aorta (changing by −0.7?mmHg per site), whereas the maximum of Px increased from the proximal to distal aorta (+4.1?mmHg per site; P? < ?0.001). The time, relative to the start of systolic upstroke, of the occurrence of the maximum excess pressure did not vary along the aorta. Of the parameters used to derive the reservoir pressure waveform the systolic and diastolic rate constants showed divergent changes with the systolic rate constant (ks) decreasing and the diastolic rate constant (kd) increasing along the aorta. CONCLUSIONS:: This analysis confirms the proposition that the magnitude of the calculated reservoir pressure waveform, despite known changes in aortic structure, is effectively constant throughout the aorta. A progressive increase of excess pressure accounts for the increase in pulse pressure from the proximal to distal aorta. The reservoir pressure rate constants seem to behave as arterial functional parameters. The accompanying decrease in ks and increase in kd are consistent with a progressive decrease in aortic compliance and increase in impedance. The reservoir pressure waveform therefore provides a model that might have utility in understanding the generation of central blood pressure and in specific cases might have clinical utility

    The REDUCE FMR Trial: A Randomized Sham-Controlled Study of Percutaneous Mitral Annuloplasty in Functional Mitral Regurgitation

    Get PDF
    Objectives This study sought to evaluate the effects of the Carillon device on mitral regurgitation severity and left ventricular remodeling. Background Functional mitral regurgitation (FMR) complicates heart failure with reduced ejection fraction and is associated with a poor prognosis. Methods In this blinded, randomized, proof-of-concept, sham-controlled trial, 120 patients receiving optimal heart failure medical therapy were assigned to a coronary sinus-based mitral annular reduction approach for FMR or sham. The pre-specified primary endpoint was change in mitral regurgitant volume at 12 months, measured by quantitative echocardiography according to an intention-to-treat analysis. Results Patients (69.8 ± 9.5 years of age) were randomized to either the treatment (n = 87) or the sham-controlled (n = 33) arm. There were no significant differences in baseline characteristics between the groups. In the treatment group, 73 of 87 (84%) had the device implanted. The primary endpoint was met, with a statistically significant reduction in mitral regurgitant volume in the treatment group compared to the control group (decrease of 7.1 ml/beat [95% confidence interval [CI]: −11.7 to −2.5] vs. an increase of 3.3 ml/beat [95% CI: −6.0 to 12.6], respectively; p = 0.049). Additionally, there was a significant reduction in left ventricular volumes in patients receiving the device versus those in the control group (left ventricular end-diastolic volume decrease of 10.4 ml [95% CI: −18.5 to −2.4] vs. an increase of 6.5 ml [95% CI: −5.1 to 18.2]; p = 0.03 and left ventricular end-systolic volume decrease of 6.2 ml [95% CI: −12.8 to 0.4] vs. an increase of 6.1 ml [95% CI: −1.42 to 13.6]; p = 0.04). Conclusions The Carillon device significantly reduced mitral regurgitant volume and left ventricular volumes in symptomatic patients with functional mitral regurgitation receiving optimal medical therapy. (Carillon Mitral Contour System for Reducing Functional Mitral Regurgitation [REDUCE FMR]; NCT02325830

    Honey, a Gift from Nature to Health and Beauty: A Review

    Get PDF
    Benefits of honey are contributed by the composition of its elements such as glucose, fructose, glucose oxidase, vitamins and phenolic compounds. For health, honey can be used to treat wounds due to the antibacterial activity conferred by the hydrogen peroxide produced by glucose oxidase in honey. Anti-inflammatory, anti-oxidant, deodorizing and tissue regeneration activities in honey also help in the wound healing process. It can also be an alternative sweetener for diabetic patients to ensure compliance to a healthy diet. Moreover, honey exerts several effects such as lowering low density lipids and increasing high density lipids, thus reducing risk of atherosclerosis. In terms of beauty, honey can be used on skin and hair. It moisturizes skin through its natural humectant properties contributed by high contents of fructose and glucose. Honey treats acne on the skin due to its antibacterial activity, anti-inflammatory action and tissue repair. The hair can benefit from honey in such a way that the hair has abundance, and becomes easier to comb. However, there have not been as many studies regarding the use of honey in skin in comparison to its use for health. Therefore, future studies on honey could research its use, action and benefits in both cosmetics and dermatology

    Clinician perceptions of factors influencing referrals to a smoking cessation program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Referral of patients to smoking cessation telephone counseling (i.e., quitline) is an underutilized resource by primary care physicians. Previously, we conducted a randomized trial to determine the effectiveness of benchmarked feedback on clinician referrals to a quitline. Subsequently, we sought to understand the successful practices used by the high-referring clinicians, and the perceptions of the barriers of referring patients to a quitline among both high and non-referring clinicians in the trial.</p> <p>Methods</p> <p>We conducted a qualitative sub-study with subjects from the randomized trial, comparing high- and non-referring clinicians. Structured interviews were conducted and two investigators employed a thematic analysis of the transcribed data. Themes and included categories were organized into a thematic framework to represent the main response sets.</p> <p>Results</p> <p>As compared to non-referring clinicians, high-referring clinicians more often reported use of the quitline as a primary source of referral, an appreciation of the quitline as an additional resource, reduced barriers to use of the quitline referral process, and a greater personal motivation related to tobacco cessation. Time and competing demands were critical barriers to initiating smoking cessation treatment with patients for all clinicians. Clinicians reported that having one referral source, a referral coordinator, and reimbursement for tobacco counseling (as a billable code) would aid referral.</p> <p>Conclusion</p> <p>Further research is needed to test the effectiveness of new approaches in improving the connection of patients with smoking cessation resources.</p> <p>Trial Registration Number</p> <p>Clinicaltrials.gov NCT00529256</p

    Genotypes and haplotypes in the insulin-like growth factors, their receptors and binding proteins in relation to plasma metabolic levels and mammographic density

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Increased mammographic density is one of the strongest independent risk factors for breast cancer. It is believed that one third of breast cancers are derived from breasts with more than 50% density. Mammographic density is affected by age, BMI, parity, and genetic predisposition. It is also greatly influenced by hormonal and growth factor changes in a woman's life cycle, spanning from puberty through adult to menopause. Genetic variations in genes coding for hormones and growth factors involved in development of the breast are therefore of great interest. The associations between genetic polymorphisms in genes from the IGF pathway on mammographic density and circulating levels of IGF1, its binding protein IGFBP3, and their ratio in postmenopausal women are reported here.</p> <p>Methods</p> <p>Samples from 964 postmenopausal Norwegian women aged 55-71 years were collected as a part of the Tromsø Mammography and Breast Cancer Study. All samples were genotyped for 25 SNPs in IGF1, IGF2, IGF1R, IGF2R, IGFALS and IGFBP3 using Taqman (ABI). The main statistical analyses were conducted with the PROC HAPLOTYPE procedure within SAS/GENETICS™ (SAS 9.1.3).</p> <p>Results</p> <p>The haplotype analysis revealed six haploblocks within the studied genes. Of those, four had significant associations with circulating levels of IGF1 or IGFBP3 and/or mammographic density. One haplotype variant in the IGF1 gene was found to be associated with mammographic density. Within the IGF2 gene one haplotype variant was associated with levels of both IGF1 and IGFBP3. Two haplotype variants in the IGF2R were associated with the level of IGF1. Both variants of the IGFBP3 haplotype were associated with the IGFBP3 level and indicate regulation in cis.</p> <p>Conclusion</p> <p>Polymorphisms within the IGF1 gene and related genes were associated with plasma levels of IGF1, IGFBP3 and mammographic density in this study of postmenopausal women.</p

    Efficacies of the new Paclitaxel-eluting Coroflex Please™ Stent in percutaneous coronary intervention; comparison of efficacy between Coroflex Please™ and Taxus™ (ECO-PLEASANT) trial: study rationale and design

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous randomized trials have showed the superiority of Paclitaxel-eluting stent over bare metal stent in angiographic and clinical outcomes. Coroflex Please™ stent is a newly developed drug eluting stent using the Coroflex™ stent platform combined with the drug paclitaxel contained in a polymer coating. PECOPS I trial, one-arm observational study, showed that the clinical and angiographic outcomes of Coroflex Please™ stent were within the range of those of Taxus, the 1<sup>st </sup>generation paclitaxel-eluting stent (PES). However, there have been no studies directly comparing the Coroflex Please™ stent with the Taxus Liberte™ stent that is the newest version of Taxus. Therefore, prospective, randomized trial is required to demonstrate the non-inferiority of Coroflex Please™ stent compared with Taxus Liberte™ stent in a head-to-head manner.</p> <p>Methods</p> <p>In the comparison of Efficacy between COroflex PLEASe™ ANd Taxus™ stent(ECO-PLEASANT) trial, approximately 900 patients are being prospectively and randomly assigned to the either type of Coroflex Please™ stent and Taxus Liberte™ stent via web-based randomization. The primary endpoint is clinically driven target vessel revascularization at 9 months. The secondary endpoints include major cardiac adverse events, target vessel failure, stent thrombosis and angiographic efficacy endpoints.</p> <p>Discussion</p> <p>The ECO-PLEASANT trial is the study not yet performed to directly compare the efficacy and safety of the Coroflex Please™ versus Taxus Liberte™ stent. On the basis of this trial, we will be able to find out whether the Coroflex Please™ stent is non-inferior to Taxus Liberte™ stent or not.</p> <p>Trial registration</p> <p>ClinicalTrials.gov number, NCT00699543.</p
    corecore