Resposta terapêutica e profilática com ferro e ácido fólico na anemia em crianças de creches públicas em Goiânia, Goiás, Brasil: ensaio clínico randomizado
The objective of this study was to assess the prevalence of anemia and the therapeutic and prophylactic response to ferrous sulfate and folic acid. A double-blind, randomized, controlled clinical trial was conducted with 196 children 6 to 24 months of age enrolled in municipal daycare centers in Goiânia, Goiás State, Brazil. The children were assigned to two treatment groups that received a daily dose (5 times a week) of either 4.2mg/kg/day of ferrous sulfate + folic acid (50µg) or 4.2mg/kg/day of ferrous sulfate + folic acid placebo. One of the prevention groups received 1.4mg/kg/day of ferrous sulfate + folic acid (50µg/day) and the other 1.4mg/kg/day of ferrous sulfate + folic acid placebo. Supplementation lasted approximately three months. Baseline anemia prevalence was 56.1% (95%CI: 48.9-63.1). After treatment, anemia prevalence in the folic acid group (14%) was lower than in the placebo group (34.9%) (p = 0.02). After prophylaxis in the non-anemic children, the incidence of anemia did not differ between the groups, but there was an increase in hemoglobin level in the folic acid group (p = 0.003). Iron plus folic acid was effective for the treatment of anemia and improvement of hemoglobin level in non-anemic children.Avaliar a prevalência de anemia e a resposta terapêutica e profilática do sulfato ferroso e ácido fólico. Realizou-se um ensaio clínico controlado randomizado, duplo-cego, com 196 crianças de 6 a 24 meses, dos Centros Municipais de Educação Infantil de Goiânia, Goiás, Brasil. As crianças foram alocadas em dois grupos de tratamento que receberam dose diária (5x/semana) com 4,2mg/kg/dia de sulfato ferroso + ácido fólico (50µg) ou 4,2mg/kg/dia de sulfato ferroso + placebo de ácido fólico. Um dos grupos de prevenção recebeu 1,4 mg/kg/dia de sulfato ferroso + ácido fólico (50µg/dia) e o outro 1,4mg/kg/dia de sulfato ferroso + placebo de ácido fólico. A suplementação durou cerca de três meses. A prevalência de anemia inicial foi de 56,1% (IC95%: 48,9-63,1). Após o tratamento, a prevalência de anemia no grupo ácido fólico (14%) foi menor que no grupo placebo (34,9%; p = 0,02). Após profilaxia dos não anêmicos, a incidência de anemia não diferiu entre os grupos, porém, houve incremento da hemoglobina no grupo ácido fólico (p = 0,003). O ferro associado com ácido fólico foi eficaz no tratamento da anemia e na melhoria da hemoglobina nos não anêmicos.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Universidade Federal de Goiás Faculdade de NutriçãoUniversidade Federal de São Paulo (UNIFESP)Universidade Federal de Goiás Instituto de Patologia Tropical e Saúde PúblicaVila São José Bento CotolengoUNIFESPSciEL
The electric vehicle in smart homes: a review and future perspectives
The electric mobility dissemination is forcing the adoption of new technologies and operation paradigms, not only focusing on smart grids, but also on smart homes. In fact, the emerging technologies for smart homes are also altering the conventional grids toward smart grids. By combining the key pillars of electric mobility and smart homes, this paper characterizes the paradigms of the electric vehicle (EV) in smart homes, presenting a review about the state of the art and establishing a relation with future perspectives. Since the smart home must be prepared to deal with the necessities of the EV, the analysis of both on board and off board battery charging systems are considered in the paper. Moreover, the in-clusion of renewable energy sources, energy storage systems, and dc electrical appliances in smart homes towards sustainability is also considered in this paper, but framed in the perspective of an EV off board battery charging system. As a pertinent contribution, this paper offers future perspectives for the EV in smart homes, including the possibility of ac, dc, and hybrid smart homes. Covering all of these aspects, exemplificative and key results are presented based on numerical simulations and experimental results obtained with a proof of concept prototype.FCT – Fundação para a Ciência e Tecnologia within the Project Scope: UID/CEC/00319/2019. This work has been supported by the FCT Project newERA4GRIDs PTDC/EEI-EEE/30283/2017, and by the FCT Project DAIPESEV PTDC/EEI-EEE/30382/2017. Tiago Sousa is supported by the doctoral scholarship SFRH/BD/134353/2017 granted by FC
Unified traction and battery charging systems for electric vehicles: a sustainability perspective
This paper presents an analysis of unified traction and battery charging systems for electric vehicles (EVs), both in terms of operation modes and in terms of implementation cost, when compared to dedicated solutions that perform the same operation modes. Regarding the connection of the EV battery charging system with the power grid, four operation modes are analyzed: (1) Grid–to–Vehicle (G2V); (2) Vehicle–to–Grid (V2G); (3) Vehicle–to–Home (V2H); and (4) Vehicle–for–Grid (V4G). With an EV unified system, each of these operation modes can be used in single–phase and three–phase power grids. Furthermore, a cost estimation is performed for an EV unified system and for dedicated systems that can perform the same functionalities, in order to prove the benefits of the EV unified approach. The cost estimation comprises two power levels, namely 6 kW, single–phase, related to domestic installations, and 50 kW, three–phase, related to industrial installations. The relevance of unified traction and battery charging systems for EVs is proven for single–phase and three–phase power grids.This work has been supported by FCT – Fundação para a Ciência e Tecnologia within the Project Scope: UID/CEC/00319/2019. This work has been supported by the FCT Project DAIPESEV PTDC/EEI-EEE/30382/2017, and by the FCT Project new ERA4GRIDs PTDC/EEI-EEE/30283/2017
The role of off-board EV battery chargers in smart homes and smart grids: operation with renewables and energy storage systems
Concerns about climate changes and environmental air pollution are leading to the adoption of new technologies for transportation, mainly based on vehicle electrification and the interaction with smart grids, and also with the introduction of renewable energy sources (RES) accompanied by energy storage systems (ESS). For these three fundamental pillars, new power electronics technologies are emerging to transform the electrical power grid, targeting a flexible and collaborative operation. As a distinctive factor, the vehicle electrification has stimulated the presence of new technologies in terms of power management, both for smart homes and smart grids. As the title indicates, this book chapter focuses on the role of off-board EV battery chargers in terms of operation modes and contextualization for smart homes and smart grids in terms of opportunities. Based on a review of on-board and off-board EV battery charging systems (EV-BCS), this chapter focus on the off-board EV-BCS framed with RES and ESS as a dominant system in future smart homes. Contextualizing these aspects, three distinct cases are considered: (1) An ac smart home using separate power converters, according to the considered technologies; (2) A hybrid ac and dc smart home with an off-board EV-BCS interfacing RES and ESS, and with the electrical appliances plugged-in to the ac power grid; (3) A dc smart home using a unified
2
off-board EV-BCS with a single interface for the electrical power grid, and with multiple dc interfaces (RES, ESS, and electrical appliances). The results for each case are obtained in terms of efficiency and power quality, demonstrating that the off-board EV-BCS, as a unified structure for smart homes, presents better results. Besides, the off-board EV-BCS can also be used as an important asset for the smart grid, even when the EV is not plugged-in at the smart home.(undefined
Frequency of LCT -13910C>T single nucleotide polymorphism associated with adult-type hypolactasia/lactase persistence among Brazilians of different ethnic groups
<p>Abstract</p> <p>Background</p> <p>Adult-type hypolactasia, the physiological decline of lactase some time after weaning, was previously associated with the LCT -13910C>T polymorphism worldwide except in Africa. Lactase non-persistence is the most common phenotype in humans, except in northwestern Europe with its long history of pastoralism and milking. We had previously shown association of LCT -13910C>T polymorphism with adult-type hypolactasia in Brazilians; thus, we assessed its frequency among different Brazilian ethnic groups.</p> <p>Methods</p> <p>We investigated the ethnicity-related frequency of this polymorphism in 567 Brazilians [mean age, 42.1 ± 16.8 years; 157 (27.7%) men]; 399 (70.4%) White, 50 (8.8%) Black, 65 (11.5%) Brown, and 53 (9.3%) Japanese-Brazilian. DNA was extracted from leukocytes; LCT -13910C>T polymorphism was analyzed by PCR-restriction fragment length polymorphism.</p> <p>Results</p> <p>Prevalence of the CC genotype associated with hypolactasia was similar (57%) among White and Brown groups; however, prevalence was higher among Blacks (80%) and those of Japanese descent (100%). Only 2 (4%) Blacks had TT genotype, and 8 (16%) had the CT genotype. Assuming an association between CC genotype and hypolactasia, and CT and TT genotypes with lactase persistence, 356 (62.8%) individuals had hypolactasia and 211 (37.2%) had lactase persistence. The White and Brown groups had the same hypolactasia prevalence (~57%); nevertheless, was 80% among Black individuals and 100% among Japanese-Brazilians (<it>P </it>< 0.01).</p> <p>Conclusion</p> <p>The lactase persistence allele, LCT -13910T, was found in about 43% of both White and Brown and 20% of the Black Brazilians, but was absent among all Japanese Brazilians studied.</p
A penalty approach to a discretized double obstacle problem with derivative constraints
This work presents a penalty approach to a nonlinear optimization problem with linear box constraints arising from the discretization of an infinite-dimensional differential obstacle problem with bound constraints on derivatives. In this approach, we first propose a penalty equation approximating the mixed nonlinear complementarity problem representing the Karush-Kuhn-Tucker conditions of the optimization problem. We then show that the solution to the penalty equation converges to that of the complementarity problem with an exponential convergence rate depending on the parameters used in the equation. Numerical experiments, carried out on a non-trivial test problem to verify the theoretical finding, show that the computed rates of convergence match the theoretical ones well
Fatores que interferem no desempenho de usuários de implante coclear em testes de percepção de fala
Objetivo : analisar os fatores que interferem no desempenho de usuários de implante coclear em testes de percepção de fala.Métodos : foram aplicados questionários e testes de percepção de fala em 25 indivíduos, de ambos os sexos, portadores de perda auditiva neurossensorial e usuários de IC unilateral.Resultados : - 48% dos participantes atingiram bom desempenho nos resultados dos testes de percepção de fala, apresentando porcentagens maiores ou iguais a 50 % de acertos. - Os participantes que obtiveram melhores resultados não são necessariamente os que possuem maior idade auditiva. - Dos 12 participantes que atingiram desempenho acima de 50%, 10 (83,3%) foram implantados mais precocemente (até 5 anos). - O uso do AASI na orelha contralateral influenciou significantemente nos índices de reconhecimento das palavras ou sentenças. - Os participantes que iniciaram o uso de AASI mais cedo não foram necessariamente os que apresentaram melhores resultados nos testes.Conclusão : a ativação mais precoce dos IC mostrou-se uma variável importante no desempenho dos testes. - O uso do AASI na orelha contralateral influenciou significantemente nos índices de reconhecimento das palavras ou sentenças
Clinical and epidemiological profile of tuberculosis in an urban area with high human development index in southeastern Brazil. Time series study
ABSTRACT CONTEXT AND OBJECTIVE: In the twenty-first century, tuberculosis remains a serious public health problem in Brazil. The aim here was to characterize tuberculosis in a municipality with a high human development index (HDI), based on clinical and epidemiological variables. DESIGN AND SETTING: Epidemiological study with analysis of incidence that included 533 new cases of tuberculosis in the municipality of Araraquara, São Paulo, reported to the Brazilian Notifiable Diseases Information System (SINAN) between 2002 and 2011. METHODS: To identify trends, this period was divided into two five-year periods (2002-2006 and 2007-2011). The incidence rates were compared using ratios and confidence intervals. RESULTS: The incidence of tuberculosis was 26.82 cases per 100,000 inhabitants, and decreased by 22% between the two periods, which was statistically significant. Cases were more prevalent among men (72.61%) and among adults between 30 and 59 years of age with non-specialized professions and low education levels. There was a statistically significant reduction in cases among individuals over 50. The age group with highest incidence was 50-59 years in the first period and 30-39 years in the second. Total recovery occurred in more than 70%. There was a reduction in the number of diagnoses made within primary care and an increase within public hospital care between the two periods. The most common coinfections were AIDS and hepatitis C. CONCLUSIONS: The incidence of tuberculosis in this municipality was lower than the national incidence, with a declining trend and a high cure rate, and the main coinfections were AIDS and hepatitis C
Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma ? method-comparison evaluations
Increased plasma lactate levels can indicate the presence of metabolic disorders in HIV infected individuals. Objective: To determine whether a portable analyzer is valid for measuring cerebrospinal fluid (CSF) and plasma lactate levels in HIV infected individuals. Method: CSF and plasma were collected from 178 subjects. Samples tested by the Accutrend® portable analyzer were compared to those tested by a reference device (SYNCHRON LX® 20). Results: The portable analyzer had in plasma sensitivity of 0.95 and specificity 0.87. For CSF the specificity was 0.95; the sensitivity 0.33; the negative predictive value was 95% and the positive predictive value 33%. Conclusions: These findings support the validity of the portable analyzer in measuring lactate concentrations in CSF that fall within the normal range. The relatively poor positive predictive value indicates that a result above the reference range may represent a “false positive test”, and should be confirmed by the reference device before concluding abnormality
- …