    Coronary artery disease prediction in women and men using chest pain characteristics and risk factors: an observational study in outpatient clinics

    Get PDF
    Objectives To assess the diagnostic value of non-acute chest pain characteristics for coronary artery disease in women and men referred to outpatient cardiology clinics. Design and setting This is an observational study performed at outpatient cardiology centres of the Netherlands. Participants The study population consisted of 1028 patients with non-acute chest pain (505 women). Analysis and results Twenty-four women (5%) and 75 men (15%) were diagnosed with coronary artery disease by invasive coronary angiography or CT angiography during regular care follow-up. Elastic net regression was performed to assess which chest pain characteristics and risk factors were of diagnostic value. The overall model selected age, provocation by temperature or stress, relief at rest and functional class as determinants and was accurate in both sexes (area under the curve (AUC) of 0.76 (95% CI 0.68 to 0.85) in women and 0.83 (95% CI 0.78 to 0.88) in men). Both sex-specific models selected age, pressuring nature, radiation, duration, frequency, progress, provocation and relief at rest as determinants. The female model additionally selected dyspnoea, body mass index, hypertension and smoking while the male model additionally selected functional class and diabetes. The sex-specific models performed better than the overall model, but more so in women (AUC: 0.89, 95% CI 0.81 to 0.96) than in men (AUC: 0.84, 95% CI 0.73 to 0.90). Conclusions In both sexes, the diagnostic value of non-acute chest pain characteristics and risk factors for coronary artery disease was high. Provocation, relief at rest and functional class of chest pain were the most powerful diagnostic predictors in both women and men. When stratified by sex the performance of the model improved, mostly in women

    Evaluation of non-invasive imaging parameters in coronary microvascular disease: a systematic review.

    Get PDF
    Background Coronary microvascular dysfunction (CMD) is an important underlying cause of angina pectoris. Currently, no diagnostic tool is available to directly visualize the coronary microvasculature. Invasive microvascular reactivity testing is the diagnostic standard for CMD, but several non-invasive imaging techniques are being evaluated. However, evidence on reported non-invasive parameters and cut-off values is limited. Thus, we aimed to provide an overview of reported non-invasive parameters and corresponding cut-off values for CMD. Methods Pubmed and EMBASE databases were systematically searched for studies enrolling patients with angina pectoris without obstructed coronary arteries, investigating at least one non-invasive imaging technique to quantify CMD. Methodological quality assessment of included studies was performed using QUADAS-2. Results Thirty-seven studies were included. Ten cardiac magnetic resonance studies reported MPRI and nine positron emission tomography (PET) and transthoracic echocardiography (TTE) studies reported CFR. Mean MPRI ranged from 1.47 ± 0.36 to 2.01 ± 0.41 in patients and from 1.50 ± 0.47 to 2.68 ± 0.49 in controls without CMD. Reported mean CFR in PET and TTE ranged from 1.39 ± 0.31 to 2.85 ± 1.35 and 1.69 ± 0.40 to 2.40 ± 0.40 for patients, and 2.68 ± 0.83 to 4.32 ± 1.78 and 2.65 ± 0.65 to 3.31 ± 1.10 for controls, respectively. Conclusions This systematic review summarized current evidence on reported parameters and cut-off values to diagnose CMD for various non-invasive imaging modalities. In current clinical practice, CMD is generally diagnosed with a CFR less than 2.0. However, due to heterogeneity in methodology and reporting of outcome measures, outcomes could not be compared and no definite reference values could be provided

    Evaluation of non-invasive imaging parameters in coronary microvascular disease: a systematic review.

    No full text
    Background Coronary microvascular dysfunction (CMD) is an important underlying cause of angina pectoris. Currently, no diagnostic tool is available to directly visualize the coronary microvasculature. Invasive microvascular reactivity testing is the diagnostic standard for CMD, but several non-invasive imaging techniques are being evaluated. However, evidence on reported non-invasive parameters and cut-off values is limited. Thus, we aimed to provide an overview of reported non-invasive parameters and corresponding cut-off values for CMD. Methods Pubmed and EMBASE databases were systematically searched for studies enrolling patients with angina pectoris without obstructed coronary arteries, investigating at least one non-invasive imaging technique to quantify CMD. Methodological quality assessment of included studies was performed using QUADAS-2. Results Thirty-seven studies were included. Ten cardiac magnetic resonance studies reported MPRI and nine positron emission tomography (PET) and transthoracic echocardiography (TTE) studies reported CFR. Mean MPRI ranged from 1.47 ± 0.36 to 2.01 ± 0.41 in patients and from 1.50 ± 0.47 to 2.68 ± 0.49 in controls without CMD. Reported mean CFR in PET and TTE ranged from 1.39 ± 0.31 to 2.85 ± 1.35 and 1.69 ± 0.40 to 2.40 ± 0.40 for patients, and 2.68 ± 0.83 to 4.32 ± 1.78 and 2.65 ± 0.65 to 3.31 ± 1.10 for controls, respectively. Conclusions This systematic review summarized current evidence on reported parameters and cut-off values to diagnose CMD for various non-invasive imaging modalities. In current clinical practice, CMD is generally diagnosed with a CFR less than 2.0. However, due to heterogeneity in methodology and reporting of outcome measures, outcomes could not be compared and no definite reference values could be provided

    Desenvolvimento da linguagem em crianças com implante coclear: terá o gênero alguma influência?

    No full text
    OBJECTIVO:avaliar a influencia do gênero no desenvolvimento da linguagem de crianças com surdez severa a profunda neurossensorial, após implante coclear.MÉTODOS:foram estudadas 30 crianças, 12 do gênero feminino e 18 do masculino, entre os 8 anos e 1 mês e os 10 anos com surdez severa a profunda neurossensorial bilateral congênita com implante coclear. Avaliaram-se as estruturas linguísticas semântica, morfossintaxe e fonologia. Utilizou-se o instrumento de avaliação: Grelha de Observação da Linguagem - nível escolar.RESULTADOS:a idade auditiva média foi de 72 meses no gênero feminino e 72.7 meses no masculino. As pontuações obtidas nos três níveis linguisticos foram estatisticamente semelhantes, quando comparados os gêneros. Nas provas de cada estrutura linguística também não se verificaram diferenças estatisticamente significantes.CONCLUSÕES:o gênero não influenciou o desenvolvimento da linguagem oral nas crianças utilizadoras de implante coclear, nas três estruturas linguísticas estudadas