385 research outputs found
Fabrication and characterization of efficiency and radiation tolerance of 3D diamond detectors
Combined Bulk and Surface Radiation Damage Effects at Very High Fluences in Silicon Detectors: Measurements and TCAD Simulations
In this work we propose a new combined TCAD radiation damage modelling
scheme, featuring both bulk and surface radiation damage effects, for the
analysis of silicon detectors aimed at the High Luminosity LHC. In particular,
a surface damage model has been developed by introducing the relevant
parameters (NOX, NIT) extracted from experimental measurements carried out on
p-type substrate test structures after gamma irradiations at doses in the range
10-500 Mrad(Si). An extended bulk model, by considering impact ionization and
deep-level cross-sections variation, was included as well. The model has been
validated through the comparison of the simulation findings with experimental
measurements carried out at very high fluences (2 10^16 1 MeV equivalent
n/cm^2) thus fostering the application of this TCAD approach for the design and
optimization of the new generation of silicon detectors to be used in future
HEP experiments.Comment: 8 pages, 14 figures. arXiv admin note: text overlap with
arXiv:1611.1013
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe
Right drug, right patient, right time: aspiration or future promise for biologics in rheumatoid arthritis?
Individualising biologic disease-modifying anti-rheumatic drugs (bDMARDs) to maximise outcomes and deliver safe and cost-effective care is a key goal in the management of rheumatoid arthritis (RA). Investigation to identify predictive tools of bDMARD response is a highly active and prolific area of research. In addition to clinical phenotyping, cellular and molecular characterisation of synovial tissue and blood in patients with RA, using different technologies, can facilitate predictive testing. This narrative review will summarise the literature for the available bDMARD classes and focus on where progress has been made. We will also look ahead and consider the increasing use of ‘omics’ technologies, the potential they hold as well as the challenges, and what is needed in the future to fully realise our ambition of personalised bDMARD treatment
Preliminary osteogenic and antibacterial investigations of wood derived antibiotic-loaded bone substitute for the treatment of infected bone defects
Introduction: The development of reliable treatments for infected or potentially infected bone loss resulting from open fractures and non-unions is extremely urgent, especially to reduce the prolonged courses of antimicrobial therapy to which affected patients are subjected. Numerous bone graft substitutes have been used over the years, but there are currently no effective solutions to treat critical bone loss, especially in the presence of infection. The present study evaluated the use of the biomorphic calcium phosphate bone scaffold b. BoneTM, based on a next-generation resorbable biomimetic biomaterial, in bone reconstruction surgery in cases of infection. Methods: Using an “in vitro 3D bone fracture model” to predict the behavior of this drug delivery system during critical bone loss at an infected (or potentially infected) site, the effects of scaffolds loaded with gentamicin or vancomycin on the viability and differentiation capacity of human mesenchymal stem cells (hMSCs) were evaluated. Results: This scaffold, when loaded with gentamicin or vancomycin, exhibits a typical drug release curve that determines the inhibitory effects on the growth of Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli, as well as relative biofilm formation. Discussion: The study demonstrates that b.bone scaffolds can effectively address key challenges in orthopedic surgery and patient care by inhibiting bacterial growth and biofilm formation through rapid, potent antibiotic release, reducing the risk of treatment failure due to resistance, and providing a promising solution for bone infections and improved patient outcomes. Future studies could explore the combination of different antibiotics on these scaffolds for more tailored and effective treatments against post-traumatic osteomyelitis pathogens
Effect of laser drilling on biomorphically engineered hydroxyapatite scaffolds derived from rattan wood
The restoration of critical-size load-bearing bone defects calls for the application of bioactive scaffolds that are regenerative, osteoconductive, and demonstrate mechanical strength comparable with natural bone. Novel hydroxyapatite (HAp) scaffolds sourced and fabricated through the biomorphic transformation of rattan wood (GreenBone-GB) were laser-drilled (LD) with parallel and lateral sub-millimetre channels, which enhanced the overall porosity for promoting the flow of cells and fluids throughout the scaffolds. The compositional analysis of the LD scaffolds confirmed the presence of the Ca5(PO4)3OH and Ca3(PO4)2 phases, with no evidence of drilling contamination. Water jet laser drilling enhanced the interconnecting porosity of the morphogenic scaffolds by 22.5 %, without obstructing the intrinsic uniaxial fibrous structure inherited from rattan wood. Across eight varied drilled patterns, the resulting scaffolds preserved the structural integrity and exhibited compressive strength ranging from 6.74 ± 1.25 to 10.18 ± 0.43 MPa, while the Vickers Hardness was comparable with natural bone. Cell viability assessments confirmed that the LD scaffolds exhibited no toxicity and presented >90 % cell viability. We demonstrate that laser drilling effectively enhanced the pore volume for improved osteoconductivity via cell migration in the bio-morphogenic GB-structure. Since the GB scaffolds are CE-marked products, laser drilling for pore surface engineering could provide improved scaffolds for clinical use
Evaluation of a 3D diamond detector for medical radiation dosimetry
Synthetic diamond has several properties that are particularly suited to applications in medical radiation dosimetry. It is tissue equivalent, not toxic and shows a high resistance to radiation damage, low leakage current and stability of response. It is an electrical insulator, robust and realizable in small size; due to these features there are several examples of diamond devices, mainly planar single-crystalline chemical vapor depositation (sCVD) diamond, used for relative dose measurement in photon beams. Thanks to a new emerging technology, diamond devices with 3-dimensional structures are produced by using laser pulses to create graphitic paths in the diamond bulk. The necessary bias voltage to operate such detector decreases considerably while the signal response and radiation resistance increase. In order to evaluate the suitability of this new technology for measuring the dose delivered by radiotherapy beams in oncology a 3D polycrystalline (pCVD) diamond detector designed for single charged particle detection has been tested and the photon beam profile has been studied. The good linearity and high sensitivity to the dose observed in the 3D diamond, opens the way to the possibility of realizing a finely segmented device with the potential for dose distribution measurement in a single exposure for small field dosimetry that nowadays is still extremely challenging
Lipoprotien(a) concentration, genetic variants, apo(a) isoform size, and cellular cholesterol efflux in patients with elevated Lp(a) and coronary heart disease submitted or not to lipoprotein apheresis: An Italian case-control multicenter study on Lp(a)
METHODS:We conducted a multicenter, observational study in Italian patients with hyperLp(a) andpremature CAD with (n518)/without (n516) LA in which blood samples were analyzed for Lp(a)parameter and CLSQ10. Genetic profiling of LPAQ11was conducted in patient receiving LA.RESULTS:Mean macrophage CLC of the pre-LA serum was significantly higher than that of nor-molipidemic controls (19.760.9mg/mg vs 16.0160.98mg/mg of protein, respectively). After LA,serum macrophage CLC was markedly lower relative to preapheresis (16.160.8mg/mg protein;P5.003) and comparable with CLC of the normolipidemic serum. LA did not significantly affectaverage apo(a) isoform size distribution. No anthropometric or lipid parameters studied were relatedto serum CLC, but there was a relationship between CLC and the Lp(a) plasma concentration(P5.035). DNA analysis revealed a range of common genetic variants. Two rare, new variantswere identified: LPA exon 21, c.3268C.G, p.Pro1090Arg, and rs41259144 p.Arg990Gln, c.2969G.ACONCLUSIONS:LA reduces serum Lp(a) and also reduces macrophage CLC. Novel genetic vari-ants of the LPA gene were identified, and geographic variations were noted. The complexity of thesepolymorphisms means that genetic assessment is not a predictor of CAD risk in hyperLp(a
Fabrication of a hydrogenated amorphous silicon detector in 3-d geometry and preliminary test on planar prototypes
Hydrogenated amorphous silicon (a-Si:H) can be produced by plasma-enhanced chemical vapor deposition (PECVD) of SiH4 (silane) mixed with hydrogen. The resulting material shows outstanding radiation hardness properties and can be deposited on a wide variety of substrates. Devices employing a-Si:H technologies have been used to detect many different kinds of radiation, namely, minimum ionizing particles (MIPs), X-rays, neutrons, and ions, as well as low-energy protons and alphas. However, the detection of MIPs using planar a-Si:H diodes has proven difficult due to their unsatisfactory S/N ratio arising from a combination of high leakage current, high capacitance, and limited charge collection efficiency (50% at best for a 30 µm planar diode). To overcome these limitations, the 3D-SiAm collaboration proposes employing a 3D detector geometry. The use of vertical electrodes allows for a small collection distance to be maintained while preserving a large detector thickness for charge generation. The depletion voltage in this configuration can be kept below 400 V with a consequent reduction in the leakage current. In this paper, following a detailed description of the fabrication process, the results of the tests performed on the planar p-i-n structures made with ion implantation of the dopants and with carrier selective contacts are illustrated
Testing of planar hydrogenated amorphous silicon sensors with charge selective contacts for the construction of 3D-detectors
Hydrogenated Amorphous Silicon (a-Si:H) is a well known material for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and dosimetry. Planar p-i-n diode detectors are fabricated entirely by means of intrinsic and doped PECVD of a mixture of Silane (SiH4) and molecular hydrogen. In order to develop 3D detector geometries using a-Si:H, two options for the junction fabrication have been considered: ion implantation and charge selective contacts through atomic layer deposition. In order to test the functionality of the charge selective contact electrodes, planar detectors have been fabricated utilizing this technique. In this paper, we provide a general overview of the 3D fabrication project followed by the results of leakage current measurements and X-ray dosimetric tests performed on planar diodes containing charge selective contacts to investigate the feasibility of the charge selective contact methodology for integration with the proposed 3D detector architectures
- …
